{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T12:33:39Z","timestamp":1790426019989,"version":"4.1.0"},"reference-count":24,"publisher":"American Diabetes Association","issue":"5","content-domain":{"domain":["diabetesjournals.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2014,5,1]]},"abstract":"<jats:sec>\n                  <jats:title>OBJECTIVE<\/jats:title>\n                  <jats:p>The goal was to develop a new index of insulin sensitivity in patients with type 1 diabetes estimated from continuous glucose monitoring (CGM) and subcutaneous insulin delivery data under carefully controlled conditions.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESEARCH DESIGN AND METHODS<\/jats:title>\n                  <jats:p>The database consists of 12 subjects with type 1 diabetes, studied during breakfast, lunch, and dinner, in a clinical research unit, wearing both subcutaneous insulin pump and CGM device. Frequent blood samples were drawn for measurements of plasma glucose and insulin concentrations in order to estimate insulin sensitivity with the oral minimal model (SIMM). The new index of insulin sensitivity (SISP) was calculated with a simple algebraic formula for each meal, using only CGM and insulin pump data and compared with SIMM.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS<\/jats:title>\n                  <jats:p>SI SP was well correlated with SIMM (r = 0.825; P &amp;lt; 10\u22128), and diurnal pattern was also similar to SIMM.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSIONS<\/jats:title>\n                  <jats:p>A novel method for estimating insulin sensitivity in subjects with type 1 diabetes on sensor-augmented insulin pump therapy has been presented. This new index correlates well with the reference oral minimal model estimate of insulin sensitivity. The knowledge of patient-specific insulin sensitivity and its diurnal variation can help in optimizing insulin therapy in type 1 diabetes and could also inform next-generation closed-loop control systems.<\/jats:p>\n               <\/jats:sec>","DOI":"10.2337\/dc13-1120","type":"journal-article","created":{"date-parts":[[2013,12,7]],"date-time":"2013-12-07T05:49:53Z","timestamp":1386395393000},"page":"1216-1223","update-policy":"https:\/\/doi.org\/10.2337\/ada-journal-policies","source":"Crossref","is-referenced-by-count":55,"title":["Quantitative Estimation of Insulin Sensitivity in Type 1 Diabetic Subjects Wearing a Sensor-Augmented Insulin Pump"],"prefix":"10.2337","volume":"37","author":[{"given":"Michele","family":"Schiavon","sequence":"first","affiliation":[{"name":"Department of Information Engineering, University of Padova, Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiara","family":"Dalla Man","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yogish C.","family":"Kudva","sequence":"additional","affiliation":[{"name":"Division of Endocrinology, Diabetes, Metabolism, and Nutrition, Department of Internal Medicine, Mayo Clinic and Foundation, Rochester, MN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ananda","family":"Basu","sequence":"additional","affiliation":[{"name":"Division of Endocrinology, Diabetes, Metabolism, and Nutrition, Department of Internal Medicine, Mayo Clinic and Foundation, Rochester, MN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudio","family":"Cobelli","sequence":"additional","affiliation":[{"name":"Department of Information Engineering, University of Padova, Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1167","published-online":{"date-parts":[[2014,4,10]]},"reference":[{"key":"2022031302062538100_B1","first-page":"E214","article-title":"Glucose clamp technique: a method for quantifying insulin secretion and resistance","volume":"237","author":"DeFronzo","year":"1979","journal-title":"Am J Physiol"},{"key":"2022031302062538100_B2","first-page":"E667","article-title":"Quantitative estimation of insulin sensitivity","volume":"236","author":"Bergman","year":"1979","journal-title":"Am J Physiol"},{"key":"2022031302062538100_B3","doi-asserted-by":"crossref","first-page":"E637","DOI":"10.1152\/ajpendo.00319.2003","article-title":"Minimal model estimation of glucose absorption and insulin sensitivity from oral test: validation with a tracer method","volume":"287","author":"Dalla Man","year":"2004","journal-title":"Am J Physiol Endocrinol Metab"},{"key":"2022031302062538100_B4","doi-asserted-by":"crossref","first-page":"E954","DOI":"10.1152\/ajpendo.00076.2005","article-title":"Insulin sensitivity by oral glucose minimal models: validation against clamp","volume":"289","author":"Dalla Man","year":"2005","journal-title":"Am J Physiol Endocrinol Metab"},{"key":"2022031302062538100_B5","doi-asserted-by":"crossref","first-page":"4396","DOI":"10.1210\/jcem.85.11.6982","article-title":"Insulin sensitivity from meal tolerance tests in normal subjects: a minimal model index","volume":"85","author":"Caumo","year":"2000","journal-title":"J Clin Endocrinol Metab"},{"key":"2022031302062538100_B6","doi-asserted-by":"crossref","first-page":"295","DOI":"10.2337\/diacare.23.3.295","article-title":"Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity","volume":"23","author":"Stumvoll","year":"2000","journal-title":"Diabetes Care"},{"key":"2022031302062538100_B7","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.2337\/diacare.22.9.1462","article-title":"Insulin sensitivity indices obtained from oral glucose tolerance testing: comparison with the euglycemic insulin clamp","volume":"22","author":"Matsuda","year":"1999","journal-title":"Diabetes Care"},{"key":"2022031302062538100_B8","doi-asserted-by":"crossref","first-page":"257","DOI":"10.2337\/dc06-1240","article-title":"The BIGTT test: a novel test for simultaneous measurement of pancreatic \u03b2-cell function, insulin sensitivity, and glucose tolerance","volume":"30","author":"Hansen","year":"2007","journal-title":"Diabetes Care"},{"key":"2022031302062538100_B9"},{"key":"2022031302062538100_B10"},{"key":"2022031302062538100_B11","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1089\/dia.2012.0245","article-title":"Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems","volume":"15","author":"Leelarathna","year":"2013","journal-title":"Diabetes Technol Ther"},{"key":"2022031302062538100_B12","doi-asserted-by":"crossref","first-page":"866","DOI":"10.2337\/dc08-1826","article-title":"Effects of type 2 diabetes on insulin secretion, insulin action, glucose effectiveness, and postprandial glucose metabolism","volume":"32","author":"Basu","year":"2009","journal-title":"Diabetes Care"},{"key":"2022031302062538100_B13","first-page":"1658","article-title":"Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach","volume-title":"IEEE Trans Biomed Eng","author":"Guerra","year":"2012"},{"key":"2022031302062538100_B14","author":"Del Favero","year":"2013","journal-title":"Retrofitting algorithm: fusing CGM and references to reconstruct a reliable continuous glucose profile"},{"key":"2022031302062538100_B15","doi-asserted-by":"crossref","first-page":"E169","DOI":"10.1152\/ajpendo.00473.2004","article-title":"A minimal model of insulin secretion and kinetics to assess hepatic insulin extraction","volume":"290","author":"Toffolo","year":"2006","journal-title":"Am J Physiol Endocrinol Metab"},{"key":"2022031302062538100_B16","doi-asserted-by":"crossref","first-page":"E941","DOI":"10.1152\/ajpendo.90842.2008","article-title":"Minimal model assessment of hepatic insulin extraction during an oral test from standard insulin kinetic parameters","volume":"297","author":"Campioni","year":"2009","journal-title":"Am J Physiol Endocrinol Metab"},{"key":"2022031302062538100_B17","doi-asserted-by":"crossref","first-page":"2986","DOI":"10.1109\/TBME.2012.2192930","article-title":"Modular closed-loop control of diabetes","volume":"59","author":"Patek","year":"2012","journal-title":"IEEE Trans Biomed Eng"},{"key":"2022031302062538100_B18","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1177\/193229680900300319","article-title":"Safety constraints in an artificial pancreatic beta cell: an implementation of model predictive control with insulin on board","volume":"3","author":"Ellingsen","year":"2009","journal-title":"J Diabetes Sci Tech"},{"key":"2022031302062538100_B19","doi-asserted-by":"crossref","first-page":"2472","DOI":"10.1109\/TBME.2006.883792","article-title":"A system model of oral glucose absorption: validation on gold standard data","volume":"53","author":"Dalla Man","year":"2006","journal-title":"IEEE Trans Biomed Eng"},{"key":"2022031302062538100_B20"},{"key":"2022031302062538100_B21","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1177\/193229680900300106","article-title":"In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes","volume":"3","author":"Kovatchev","year":"2009","journal-title":"J Diabetes Sci Tech"},{"key":"2022031302062538100_B22","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1089\/dia.2009.0145","article-title":"STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: research design, methods, and baseline characteristics of enrolled subjects","volume":"12","author":"Davis","year":"2010","journal-title":"Diabetes Technol Ther"},{"key":"2022031302062538100_B23"},{"key":"2022031302062538100_B24","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1002\/dmrr.727","article-title":"Calculating the insulin to carbohydrate ratio using the hyperinsulinaemic-euglycaemic clamp-a novel use for a proven technique","volume":"23","author":"Bevier","year":"2007","journal-title":"Diabetes Metab Res Rev"}],"container-title":["Diabetes Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/37\/5\/1216\/620162\/1216.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/37\/5\/1216\/620162\/1216.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,13]],"date-time":"2022-03-13T06:14:08Z","timestamp":1647152048000},"score":1,"resource":{"primary":{"URL":"https:\/\/diabetesjournals.org\/care\/article\/37\/5\/1216\/38067\/Quantitative-Estimation-of-Insulin-Sensitivity-in"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4,10]]},"references-count":24,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2014,4,10]]},"published-print":{"date-parts":[[2014,5,1]]}},"URL":"https:\/\/doi.org\/10.2337\/dc13-1120","relation":{},"ISSN":["0149-5992","1935-5548"],"issn-type":[{"value":"0149-5992","type":"print"},{"value":"1935-5548","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,4,10]]}}}