{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T11:27:47Z","timestamp":1790422067980,"version":"4.1.0"},"reference-count":10,"publisher":"American Diabetes Association","issue":"7","license":[{"start":{"date-parts":[[2022,4,29]],"date-time":"2022-04-29T00:00:00Z","timestamp":1651190400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.diabetesjournals.org\/content\/license"}],"content-domain":{"domain":["diabetesjournals.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,7,7]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Continuous glucose monitoring (CGM) improves diabetes management, but its reliability in individuals on hemodialysis is poorly understood and potentially affected by interstitial and intravascular volume variations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESEARCH DESIGN AND METHODS<\/jats:title>\n                    <jats:p>We assessed the accuracy of a factory-calibrated CGM by using venous blood glucose measurements (vBGM) during hemodialysis sessions and self-monitoring blood glucose (SMBG) at home.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>Twenty participants completed the protocol. The mean absolute relative difference of the CGM was 13.8% and 14.4%, when calculated on SMBG (n = 684) and on vBGM (n = 624), and 98.7% and 100% of values in the Parkes error grid A\/B zones, respectively. Throughout 181 days of CGM monitoring, the median time in range (70\u2013180 mg\/dL) was 38.5% (interquartile range 29.3\u201357.9), with 28.7% (7.8\u201340.6) of the time &amp;gt;250 mg\/dL.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>The overall performance of a factory-calibrated CGM appears reasonably accurate and clinically relevant for use in practice by individuals on hemodialysis and health professionals to improve diabetes management.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2337\/dc22-0073","type":"journal-article","created":{"date-parts":[[2022,4,29]],"date-time":"2022-04-29T09:14:34Z","timestamp":1651223674000},"page":"1666-1669","update-policy":"https:\/\/doi.org\/10.2337\/ada-journal-policies","source":"Crossref","is-referenced-by-count":43,"title":["Accuracy of a Factory-Calibrated Continuous Glucose Monitor in Individuals With Diabetes on Hemodialysis"],"prefix":"10.2337","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7420-1425","authenticated-orcid":false,"given":"Orianne","family":"Villard","sequence":"first","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"},{"name":"2Department of Endocrinology, Diabetes, and Nutrition, Montpellier University Hospital, Montpellier, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7645-2693","authenticated-orcid":false,"given":"Marc D.","family":"Breton","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Swati","family":"Rao","sequence":"additional","affiliation":[{"name":"3Division of Transplant Nephrology, Department of Medicine, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary K.","family":"Voelmle","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Morgan R.","family":"Fuller","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helen E.","family":"Myers","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan K.","family":"McFadden","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zander S.","family":"Luke","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian A.","family":"Wakeman","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary","family":"Clancy-Oliveri","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ananda","family":"Basu","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"},{"name":"4Division of Endocrinology and Metabolism, Department of Medicine, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meaghan M.","family":"Stumpf","sequence":"additional","affiliation":[{"name":"1Center for Diabetes Technology, University of Virginia, Charlottesville, VA"},{"name":"4Division of Endocrinology and Metabolism, Department of Medicine, University of Virginia, Charlottesville, VA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1167","published-online":{"date-parts":[[2022,4,29]]},"reference":[{"key":"2022070714525607800_B1","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1210\/endrev\/bnaa017","article-title":"Glycemic monitoring and management in advanced chronic kidney disease","volume":"41","author":"Galindo","year":"2020","journal-title":"Endocr Rev"},{"key":"2022070714525607800_B2","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.2337\/dc21-0269","article-title":"Hemodialysis-related glycemic disarray proven by continuous glucose monitoring: glycemic markers and hypoglycemia","volume":"44","author":"Hayashi","year":"2021","journal-title":"Diabetes Care"},{"key":"2022070714525607800_B3","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1159\/000511614","article-title":"The use of HbA1c, glycated albumin and continuous glucose monitoring to assess glucose control in the chronic kidney disease population including dialysis","volume":"145","author":"Bomholt","year":"2021","journal-title":"Nephron"},{"key":"2022070714525607800_B4","doi-asserted-by":"crossref","first-page":"1471","DOI":"10.1038\/s41591-021-01453-z","article-title":"Fully automated closed-loop glucose control compared with standard insulin therapy in adults with type 2 diabetes requiring dialysis: an open-label, randomized crossover trial [published correction appears in Nat Med 2021;27:1850]","volume":"27","author":"Boughton","year":"2021","journal-title":"Nat Med"},{"key":"2022070714525607800_B5","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1177\/193229681300700517","article-title":"Technical aspects of the Parkes error grid","volume":"7","author":"Pf\u00fctzner","year":"2013","journal-title":"J Diabetes Sci Technol"},{"key":"2022070714525607800_B6","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1177\/1932296814539590","article-title":"Computing the surveillance error grid analysis: procedure and examples","volume":"8","author":"Kovatchev","year":"2014","journal-title":"J Diabetes Sci Technol"},{"key":"2022070714525607800_B7","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.2337\/dc18-1581","article-title":"Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring","volume":"41","author":"Bergenstal","year":"2018","journal-title":"Diabetes Care"},{"key":"2022070714525607800_B8","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.2337\/dci19-0028","article-title":"Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range","volume":"42","author":"Battelino","year":"2019","journal-title":"Diabetes Care"},{"key":"2022070714525607800_B9","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1177\/1932296819882690","article-title":"Comparison of interstitial fluid glucose levels obtained by continuous glucose monitoring and flash glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis","volume":"14","author":"Yajima","year":"2020","journal-title":"J Diabetes Sci Technol"},{"key":"2022070714525607800_B10","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1177\/1932296820975057","article-title":"Accuracy of flash glucose monitoring in patients with diabetes mellitus on hemodialysis and its relationship with hydration status","volume":"15","author":"Genua","year":"2021","journal-title":"J Diabetes Sci Technol"}],"container-title":["Diabetes Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/45\/7\/1666\/685193\/dc220073.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/45\/7\/1666\/685193\/dc220073.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,7]],"date-time":"2022-07-07T10:55:02Z","timestamp":1657191302000},"score":1,"resource":{"primary":{"URL":"https:\/\/diabetesjournals.org\/care\/article\/45\/7\/1666\/145075\/Accuracy-of-a-Factory-Calibrated-Continuous"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,29]]},"references-count":10,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2022,4,29]]},"published-print":{"date-parts":[[2022,7,7]]}},"URL":"https:\/\/doi.org\/10.2337\/dc22-0073","relation":{"has-preprint":[{"id-type":"doi","id":"10.2337\/figshare.19491329","asserted-by":"object"},{"id-type":"doi","id":"10.2337\/figshare.19491329.v1","asserted-by":"object"}]},"ISSN":["0149-5992"],"issn-type":[{"value":"0149-5992","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4,29]]}}}