{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T08:50:13Z","timestamp":1790412613694,"version":"4.1.0"},"reference-count":15,"publisher":"American Diabetes Association","issue":"6","license":[{"start":{"date-parts":[[2023,4,12]],"date-time":"2023-04-12T00:00:00Z","timestamp":1681257600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.diabetesjournals.org\/journals\/pages\/license"}],"funder":[{"name":"Health and Medical Research Fund Commisionned Program for Phase 1 Clinical Trial Centre"},{"name":"Medtronic External Research Program","award":["ERP-2020-12226"],"award-info":[{"award-number":["ERP-2020-12226"]}]}],"content-domain":{"domain":["diabetesjournals.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,6,1]]},"abstract":"<jats:sec>\n                  <jats:title>OBJECTIVE<\/jats:title>\n                  <jats:p>To evaluate the performance of a real-time continuous glucose monitor (CGM) in individuals with diabetes on peritoneal dialysis (PD).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESEARCH DESIGN AND METHODS<\/jats:title>\n                  <jats:p>Thirty participants with type 2 diabetes on continuous ambulatory PD wore a Guardian Sensor 3 on the upper arm paired with Guardian Connect for 14 days. We compared CGM readings against Yellow Springs Instrument (YSI) venous glucose during an 8-h in-clinic session with glucose challenge.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS<\/jats:title>\n                  <jats:p>The mean absolute relative difference (MARD) was 10.4% (95% CI 9.6, 11.7) from 941 CGM-YSI matched pairs; 81.3% of readings were within %15\/15 of YSI values in the full glycemic range. Consensus error grid analysis showed 99.9% of sensor values in zones A and B. There were no correlations between pH, uremia, hydration status, and MARD.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSIONS<\/jats:title>\n                  <jats:p>We showed satisfactory performance of a real-time CGM sensor in PD patients with diabetes, supporting future use to facilitate treatment decisions.<\/jats:p>\n               <\/jats:sec>","DOI":"10.2337\/dc22-2348","type":"journal-article","created":{"date-parts":[[2023,4,12]],"date-time":"2023-04-12T21:28:07Z","timestamp":1681334887000},"page":"1191-1195","update-policy":"https:\/\/doi.org\/10.2337\/ada-journal-policies","source":"Crossref","is-referenced-by-count":26,"title":["Evaluation of a Fourth-Generation Subcutaneous Real-Time Continuous Glucose Monitor (CGM) in Individuals With Diabetes on Peritoneal Dialysis"],"prefix":"10.2337","volume":"46","author":[{"given":"Jack K.C.","family":"Ng","sequence":"first","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Ling","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea O.Y.","family":"Luk","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"},{"name":"2Phase 1 Clinical Trial Centre, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"},{"name":"3Hong Kong Institute of Diabetes and Obesity,Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric S.H.","family":"Lau","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald C.W.","family":"Ma","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"},{"name":"3Hong Kong Institute of Diabetes and Obesity,Hong Kong SAR"},{"name":"4Li Ka Shing Institute of Health Sciences, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip K.T.","family":"Li","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheuk Chun","family":"Szeto","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"},{"name":"4Li Ka Shing Institute of Health Sciences, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juliana C.N.","family":"Chan","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"},{"name":"3Hong Kong Institute of Diabetes and Obesity,Hong Kong SAR"},{"name":"4Li Ka Shing Institute of Health Sciences, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4147-3387","authenticated-orcid":false,"given":"Elaine","family":"Chow","sequence":"additional","affiliation":[{"name":"1Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"},{"name":"2Phase 1 Clinical Trial Centre, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1167","published-online":{"date-parts":[[2023,4,12]]},"reference":[{"key":"2023052319010157500_B1","doi-asserted-by":"crossref","first-page":"2032","DOI":"10.2215\/CJN.11491116","article-title":"Diabetic kidney disease: challenges, progress, and possibilities","volume":"12","author":"Alicic","year":"2017","journal-title":"Clin J Am Soc Nephrol"},{"key":"2023052319010157500_B2","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1111\/nep.14042","article-title":"Peritoneal dialysis first policy in Hong Kong for 35\u2009years: global impact","volume":"27","author":"Li","year":"2022","journal-title":"Nephrology (Carlton)"},{"key":"2023052319010157500_B3","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1046\/j.1523-1755.2003.00209.x","article-title":"Glycemic control in diabetic CAPD patients assessed by continuous glucose monitoring system (CGMS)","volume":"64","author":"Marshall","year":"2003","journal-title":"Kidney Int"},{"key":"2023052319010157500_B4","doi-asserted-by":"crossref","first-page":"869899","DOI":"10.3389\/fendo.2022.869899","article-title":"Use of continuous glucose monitoring in the assessment and management of patients with diabetes and chronic kidney disease","volume":"13","author":"Ling","year":"2022","journal-title":"Front Endocrinol (Lausanne)"},{"key":"2023052319010157500_B5","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.kint.2020.06.019","article-title":"KDIGO 2020 clinical practice guideline for diabetes management in chronic kidney disease","volume":"98","author":"Kidney Disease: Improving Global Outcomes (KDIGO) Diabetes Work Group","year":"2020","journal-title":"Kidney Int"},{"key":"2023052319010157500_B6","doi-asserted-by":"crossref","first-page":"1666","DOI":"10.2337\/dc22-0073","article-title":"Accuracy of a factory-calibrated continuous glucose monitor in individuals with diabetes on hemodialysis","volume":"45","author":"Villard","year":"2022","journal-title":"Diabetes Care"},{"key":"2023052319010157500_B7","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1111\/1744-9987.13618","article-title":"Assessment of the accuracy of an intermittent-scanning continuous glucose monitoring device in patients with type 2 diabetes mellitus undergoing hemodialysis (AIDT2H) study","volume":"25","author":"Toyoda","year":"2021","journal-title":"Ther Apher Dial"},{"key":"2023052319010157500_B8","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1177\/1932296819882690","article-title":"Comparison of interstitial fluid glucose levels obtained by continuous glucose monitoring and flash glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis","volume":"14","author":"Yajima","year":"2020","journal-title":"J Diabetes Sci Technol"},{"key":"2023052319010157500_B9","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1177\/1932296817730376","article-title":"Impact of a basal-bolus insulin regimen on metabolic control and risk of hypoglycemia in patients with diabetes undergoing peritoneal dialysis","volume":"12","author":"G\u00f3mez","year":"2018","journal-title":"J Diabetes Sci Technol"},{"key":"2023052319010157500_B10","doi-asserted-by":"crossref","first-page":"7794","DOI":"10.12998\/wjcc.v10.i22.7794","article-title":"Performance of Dexcom G5 and FreeStyle Libre sensors tested simultaneously in people with type 1 or 2 diabetes and advanced chronic kidney Boehringer isease","volume":"10","author":"\u00d3lafsd\u00f3ttir","year":"2022","journal-title":"World J Clin Cases"},{"key":"2023052319010157500_B11","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/MNH.0000000000000466","article-title":"Fluid management and bioimpedance study in peritoneal dialysis","volume":"28","author":"Ng","year":"2019","journal-title":"Curr Opin Nephrol Hypertens"},{"key":"2023052319010157500_B12","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1089\/dia.2017.0087","article-title":"Accuracy of a fourth-generation subcutaneous continuous glucose sensor","volume":"19","author":"Christiansen","year":"2017","journal-title":"Diabetes Technol Ther"},{"key":"2023052319010157500_B13","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1038\/nrneph.2015.38","article-title":"Haemodialysis-induced hypoglycaemia and glycaemic disarrays","volume":"11","author":"Abe","year":"2015","journal-title":"Nat Rev Nephrol"},{"key":"2023052319010157500_B14","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1177\/1932296820975057","article-title":"Accuracy of flash glucose monitoring in patients with diabetes mellitus on hemodialysis and its relationship with hydration status","volume":"15","author":"Genua","year":"2021","journal-title":"J Diabetes Sci Technol"},{"key":"2023052319010157500_B15","doi-asserted-by":"crossref","first-page":"e57762","DOI":"10.1371\/journal.pone.0057762","article-title":"Glycosylated hemoglobin and albumin-corrected fructosamine are good indicators for glycemic control in peritoneal dialysis patients","volume":"8","author":"Lee","year":"2013","journal-title":"PLoS One"}],"container-title":["Diabetes Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/46\/6\/1191\/704241\/dc222348.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/46\/6\/1191\/704241\/dc222348.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,23]],"date-time":"2023-05-23T19:01:50Z","timestamp":1684868510000},"score":1,"resource":{"primary":{"URL":"https:\/\/diabetesjournals.org\/care\/article\/46\/6\/1191\/148678\/Evaluation-of-a-Fourth-Generation-Subcutaneous"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,12]]},"references-count":15,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,4,12]]},"published-print":{"date-parts":[[2023,6,1]]}},"URL":"https:\/\/doi.org\/10.2337\/dc22-2348","relation":{},"ISSN":["0149-5992","1935-5548"],"issn-type":[{"value":"0149-5992","type":"print"},{"value":"1935-5548","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,12]]}}}