{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T18:53:25Z","timestamp":1791312805369,"version":"4.3.1"},"reference-count":38,"publisher":"American Diabetes Association","issue":"6","license":[{"start":{"date-parts":[[2024,2,27]],"date-time":"2024-02-27T00:00:00Z","timestamp":1708992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.diabetesjournals.org\/journals\/pages\/license"}],"content-domain":{"domain":["diabetesjournals.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,6,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESEARCH DESIGN AND METHODS<\/jats:title>\n                    <jats:p>We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (&amp;lt;1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2337\/dc23-1663","type":"journal-article","created":{"date-parts":[[2024,2,27]],"date-time":"2024-02-27T11:46:39Z","timestamp":1709034399000},"page":"956-963","update-policy":"https:\/\/doi.org\/10.2337\/ada-journal-policies","source":"Crossref","is-referenced-by-count":40,"title":["Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation"],"prefix":"10.2337","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7132-5134","authenticated-orcid":false,"given":"Barbora","family":"Voglov\u00e1 Hagerf","sequence":"first","affiliation":[{"name":"1Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"},{"name":"2First Faculty of Medicine, Charles University, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6595-6877","authenticated-orcid":false,"given":"Marek","family":"Protus","sequence":"additional","affiliation":[{"name":"2First Faculty of Medicine, Charles University, Prague, Czech Republic"},{"name":"3Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lenka","family":"Nemetova","sequence":"additional","affiliation":[{"name":"1Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5322-4612","authenticated-orcid":false,"given":"Milos","family":"Mraz","sequence":"additional","affiliation":[{"name":"1Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"},{"name":"2First Faculty of Medicine, Charles University, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3930-623X","authenticated-orcid":false,"given":"Eva","family":"Kieslichova","sequence":"additional","affiliation":[{"name":"2First Faculty of Medicine, Charles University, Prague, Czech Republic"},{"name":"3Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0412-4137","authenticated-orcid":false,"given":"Eva","family":"Uchytilova","sequence":"additional","affiliation":[{"name":"2First Faculty of Medicine, Charles University, Prague, Czech Republic"},{"name":"3Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Veronika","family":"Indrova","sequence":"additional","affiliation":[{"name":"3Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Lelito","sequence":"additional","affiliation":[{"name":"3Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0944-8189","authenticated-orcid":false,"given":"Peter","family":"Girman","sequence":"additional","affiliation":[{"name":"1Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0201-6888","authenticated-orcid":false,"given":"Martin","family":"Haluz\u00edk","sequence":"additional","affiliation":[{"name":"1Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"},{"name":"2First Faculty of Medicine, Charles University, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5094-7724","authenticated-orcid":false,"given":"Janka","family":"Franekova","sequence":"additional","affiliation":[{"name":"4Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"},{"name":"7Third Faculty of Medicine, Charles University, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Veronika","family":"Svirlochova","sequence":"additional","affiliation":[{"name":"4Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6394-6862","authenticated-orcid":false,"given":"David C.","family":"Klonoff","sequence":"additional","affiliation":[{"name":"5Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5459-5044","authenticated-orcid":false,"given":"Michael A.","family":"Kohn","sequence":"additional","affiliation":[{"name":"6University of California San Francisco, San Francisco, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4144-3129","authenticated-orcid":false,"given":"Antonin","family":"Jabor","sequence":"additional","affiliation":[{"name":"4Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic"},{"name":"7Third Faculty of Medicine, Charles University, Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1167","published-online":{"date-parts":[[2024,2,27]]},"reference":[{"key":"2024052018523263100_B1","doi-asserted-by":"crossref","first-page":"108502","DOI":"10.1016\/j.diabres.2020.108502","article-title":"Continuous glucose monitoring: the achievement of 100\u00a0years of innovation in diabetes technology","volume":"170","author":"Galindo","year":"2020","journal-title":"Diabetes Res Clin Pract"},{"key":"2024052018523263100_B2","doi-asserted-by":"crossref","first-page":"S267","DOI":"10.2337\/dc23-S016","article-title":"16. Diabetes care in the hospital: Standards of Care in Diabetes\u20132023","volume":"46","author":"ElSayed","year":"2023","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B3","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1016\/j.eprac.2022.08.002","article-title":"American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan\u20132022 Update","volume":"28","author":"Blonde","year":"2022","journal-title":"Endocr Pract"},{"key":"2024052018523263100_B4","doi-asserted-by":"crossref","first-page":"2101","DOI":"10.1210\/clinem\/dgac278","article-title":"Management of hyperglycemia in hospitalized adult patients in non-critical care settings: an Endocrine Society clinical practice guideline","volume":"107","author":"Korytkowski","year":"2022","journal-title":"J Clin Endocrinol Metab"},{"key":"2024052018523263100_B5","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1177\/1932296820954163","article-title":"Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline","volume":"14","author":"Galindo","year":"2020","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B6","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1186\/s13054-017-1784-0","article-title":"Continuous glucose monitoring in the ICU: clinical considerations and consensus","volume":"21","author":"Krinsley","year":"2017","journal-title":"Crit Care"},{"key":"2024052018523263100_B7","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1177\/1932296820932903","article-title":"Implementation of continuous glucose monitoring in the hospital: emergent considerations for remote glucose monitoring during the COVID-19 pandemic","volume":"14","author":"Galindo","year":"2020","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B8","author":"U.S. Food and Drug Administration","year":"2020"},{"key":"2024052018523263100_B9","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1177\/1932296820964264","article-title":"Continuous glucose monitoring in critically ill patients with COVID-19: results of an emergent pilot study","volume":"14","author":"Sadhu","year":"2020","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B10","doi-asserted-by":"crossref","first-page":"847","DOI":"10.2337\/dc20-2219","article-title":"Continuous glucose monitoring in the intensive care unit during the COVID-19 pandemic","volume":"44","author":"Agarwal","year":"2021","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B11","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1177\/1932296820985263","article-title":"Outcomes and healthcare provider perceptions of real-time continuous glucose monitoring (rtCGM) in patients with diabetes and COVID-19 admitted to the ICU","volume":"15","author":"Chow","year":"2021","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B12","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.2337\/dc20-2085","article-title":"Remote continuous glucose monitoring with a computerized insulin infusion protocol for critically ill patients in a COVID-19 medical ICU: proof of concept","volume":"44","author":"Davis","year":"2021","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B13","doi-asserted-by":"crossref","first-page":"e4007","DOI":"10.1210\/clinem\/dgab409","article-title":"Use of continuous glucose monitor in critically ill COVID-19 patients requiring insulin infusion: an observational study","volume":"106","author":"Faulds","year":"2021","journal-title":"J Clin Endocrinol Metab"},{"key":"2024052018523263100_B14","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1177\/19322968211008446","article-title":"Use and accuracy of inpatient CGM during the COVID-19 pandemic: an observational study of general medicine and ICU patients","volume":"16","author":"Longo","year":"2022","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B15","doi-asserted-by":"crossref","first-page":"e168","DOI":"10.2337\/dc20-0670","article-title":"A pilot study of the feasibility and accuracy of inpatient continuous glucose monitoring","volume":"43","author":"Nair","year":"2020","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B16","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1111\/dom.14073","article-title":"Performance of a factory-calibrated, real-time continuous glucose monitoring system during elective abdominal surgery","volume":"22","author":"Tripyla","year":"2020","journal-title":"Diabetes Obes Metab"},{"key":"2024052018523263100_B17","doi-asserted-by":"crossref","first-page":"e50","DOI":"10.2337\/dc20-2386","article-title":"Continuous glucose monitoring in the operating room and cardiac intensive care unit","volume":"44","author":"Perez-Guzman","year":"2021","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B18"},{"key":"2024052018523263100_B19","doi-asserted-by":"crossref","first-page":"2076","DOI":"10.2337\/dc22-0438","article-title":"Perioperative fully closed-loop insulin delivery in patients undergoing elective surgery: an open-label, randomized controlled trial","volume":"45","author":"Herzig","year":"2022","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B20","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1089\/dia.2022.0400","article-title":"Fully closed-loop insulin delivery in patients undergoing pancreatic surgery","volume":"25","author":"Krutkyte","year":"2023","journal-title":"Diabetes Technol Ther"},{"key":"2024052018523263100_B21","author":"Roos","year":"2023"},{"key":"2024052018523263100_B22","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1056\/NEJMoa011300","article-title":"Intensive insulin therapy in critically ill patients","volume":"345","author":"van den Berghe","year":"2001","journal-title":"N Engl J Med"},{"key":"2024052018523263100_B23","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1056\/NEJMoa0810625","article-title":"Intensive versus conventional glucose control in critically ill patients","volume":"360","author":"Finfer","year":"2009","journal-title":"N Engl J Med"},{"key":"2024052018523263100_B24","doi-asserted-by":"crossref","first-page":"e95","DOI":"10.1002\/bjs.10424","article-title":"Meta-analysis of lower perioperative blood glucose target levels for reduction of surgical-site infection","volume":"104","author":"de Vries","year":"2017","journal-title":"Br J Surg"},{"key":"2024052018523263100_B25","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.1007\/s00134-009-1585-2","article-title":"A prospective randomised multi-centre controlled trial on tight glucose control by intensive insulin therapy in adult intensive care units: the Glucontrol study","volume":"35","author":"Preiser","year":"2009","journal-title":"Intensive Care Med"},{"key":"2024052018523263100_B26","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1177\/19322968211065065","article-title":"Interferences with CGM systems: practical relevance?","volume":"16","author":"Heinemann","year":"2022","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B27","doi-asserted-by":"crossref","first-page":"8831659","DOI":"10.1155\/2021\/8831659","article-title":"Changes in sepsis biomarkers after immunosuppressant administration in transplant patients","volume":"2021","author":"Franekov\u00e1","year":"2021","journal-title":"Mediators Inflamm"},{"key":"2024052018523263100_B28","author":"Werner","year":"2016"},{"key":"2024052018523263100_B29","doi-asserted-by":"crossref","first-page":"289","DOI":"10.4103\/joacp.JOACP_390_16","article-title":"Coagulopathy during liver transplantation","volume":"34","author":"Saracoglu","year":"2018","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"2024052018523263100_B30","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1177\/1932296818801607","article-title":"A milestone in point of care capillary blood glucose monitoring of critically ill hospitalized patients","volume":"12","author":"Klonoff","year":"2018","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B31","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1177\/1932296814539589","article-title":"The surveillance error grid","volume":"8","author":"Klonoff","year":"2014","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B32","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.2337\/diacare.23.8.1143","article-title":"A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose","volume":"23","author":"Parkes","year":"2000","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B33","doi-asserted-by":"crossref","first-page":"622","DOI":"10.2337\/diacare.10.5.622","article-title":"Evaluating clinical accuracy of systems for self-monitoring of blood glucose","volume":"10","author":"Clarke","year":"1987","journal-title":"Diabetes Care"},{"key":"2024052018523263100_B34","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1177\/1932296814539590","article-title":"Computing the surveillance error grid analysis: procedure and examples","volume":"8","author":"Kovatchev","year":"2014","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B35","author":"International Organization for Standardization"},{"key":"2024052018523263100_B36","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1177\/19322968231194643","article-title":"Alternative site of RT-CGM sensor application for abdominal surgery in the infraclavicular region","volume":"17","author":"Voglov\u00e1 Hagerf","year":"2023","journal-title":"J Diabetes Sci Technol"},{"key":"2024052018523263100_B37","author":"U.S. Food and Drug Administration. Blood glucose monitoring test systems for prescription point-of-care use guidance for industry and Food and Drug Administration staff"},{"key":"2024052018523263100_B38","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.mayocp.2017.03.009","article-title":"Blood gas analyzer accuracy of glucose measurements","volume":"92","author":"Liang","year":"2017","journal-title":"Mayo Clin Proc"}],"container-title":["Diabetes Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/47\/6\/956\/764758\/dc231663.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/diabetesjournals.org\/care\/article-pdf\/47\/6\/956\/764758\/dc231663.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,20]],"date-time":"2024-05-20T14:55:02Z","timestamp":1716216902000},"score":1,"resource":{"primary":{"URL":"https:\/\/diabetesjournals.org\/care\/article\/47\/6\/956\/154297\/Accuracy-and-Feasibility-of-Real-time-Continuous"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,27]]},"references-count":38,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,2,27]]},"published-print":{"date-parts":[[2024,6,1]]}},"URL":"https:\/\/doi.org\/10.2337\/dc23-1663","relation":{},"ISSN":["0149-5992","1935-5548"],"issn-type":[{"value":"0149-5992","type":"print"},{"value":"1935-5548","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,27]]}}}