{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T18:12:45Z","timestamp":1792606365563,"version":"4.5.0"},"reference-count":68,"publisher":"American Diabetes Association","issue":"3","license":[{"start":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:00:00Z","timestamp":1755216000000},"content-version":"vor","delay-in-days":14,"URL":"https:\/\/www.diabetesjournals.org\/journals\/pages\/license"}],"content-domain":{"domain":["diabetesjournals.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,8,1]]},"abstract":"<jats:p>Advancements in automated insulin delivery (AID) systems have transformed type 1 diabetes management, making AID the most effective technology for improving metabolic outcomes and quality of life in individuals with the disease. In this article, we review the available AID systems and their key features through case vignettes that illustrate their real-world applications in type 1 diabetes management. We then examine existing gaps in technology and explore future advancements to further enhance AID functionality and adoption.<\/jats:p>","DOI":"10.2337\/dsi25-0003","type":"journal-article","created":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T19:02:08Z","timestamp":1755284528000},"page":"217-227","update-policy":"https:\/\/doi.org\/10.2337\/ada-journal-policies","source":"Crossref","is-referenced-by-count":6,"title":["Automated Insulin Delivery for Type 1 Diabetes: Present and Future"],"prefix":"10.2337","volume":"38","author":[{"given":"Tugce","family":"Akcan","sequence":"first","affiliation":[{"name":"Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University 1 , Stanford, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming Yeh","family":"Lee","sequence":"additional","affiliation":[{"name":"Division of Pediatric Endocrinology, Department of Pediatrics, Stanford University 2 , Stanford, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leor","family":"Needleman","sequence":"additional","affiliation":[{"name":"Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University 1 , Stanford, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8055-944X","authenticated-orcid":false,"given":"Rayhan A.","family":"Lal","sequence":"additional","affiliation":[{"name":"Division of Endocrinology, Gerontology and Metabolism, Department of Medicine, Stanford University 1 , Stanford, CA"},{"name":"Division of Pediatric Endocrinology, Department of Pediatrics, Stanford University 2 , Stanford, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1167","published-online":{"date-parts":[[2025,8,15]]},"reference":[{"key":"2026061813515794000_B1","doi-asserted-by":"crossref","first-page":"17016","DOI":"10.1038\/nrdp.2017.16","article-title":"Type 1 diabetes mellitus","volume":"3","author":"Katsarou","year":"2017","journal-title":"Nat Rev Dis Primers"},{"key":"2026061813515794000_B2","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1056\/NEJM199309303291401","article-title":"The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus","volume":"329","author":"DCCT Research Group","year":"1993","journal-title":"N Engl J Med"},{"key":"2026061813515794000_B3","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1089\/dia.2018.0384","article-title":"State of type 1 diabetes management and outcomes from the T1D Exchange in 2016\u20132018","volume":"21","author":"Foster","year":"2019","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B4","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1210\/endrev\/bnac022","article-title":"Consensus recommendations for the use of automated insulin delivery technologies in clinical practice","volume":"44","author":"Phillip","year":"2023","journal-title":"Endocr Rev"},{"key":"2026061813515794000_B5","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/S2213-8587(17)30167-5","article-title":"Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials","volume":"5","author":"Weisman","year":"2017","journal-title":"Lancet Diabetes Endocrinol"},{"key":"2026061813515794000_B6","doi-asserted-by":"crossref","first-page":"k1310","DOI":"10.1136\/bmj.k1310","article-title":"Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis","volume":"361","author":"Bekiari","year":"2018","journal-title":"BMJ"},{"key":"2026061813515794000_B7","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1056\/NEJMoa1907863","article-title":"Six-month randomized, multicenter trial of closed-loop control in type 1 diabetes","volume":"381","author":"Brown","year":"2019","journal-title":"N Engl J Med"},{"key":"2026061813515794000_B8","doi-asserted-by":"crossref","first-page":"1831","DOI":"10.2337\/dc23-0635","article-title":"Hybrid closed-loop therapy in adults with type 1 diabetes and above-target HbA1c: a real-world observational study","volume":"46","author":"Crabtree","year":"2023","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B9","doi-asserted-by":"crossref","first-page":"2300","DOI":"10.2337\/dc23-0504","article-title":"Automated insulin delivery systems in children and adolescents with type 1 diabetes: a systematic review and meta-analysis of outpatient randomized controlled trials","volume":"46","author":"Zeng","year":"2023","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B10","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1056\/NEJMoa2210834","article-title":"Trial of hybrid closed-loop control in young children with type 1 diabetes","volume":"388","author":"Wadwa","year":"2023","journal-title":"N Engl J Med"},{"key":"2026061813515794000_B11","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1007\/s00125-024-06155-y","article-title":"Comparison between a tubeless, on-body automated insulin delivery system and a tubeless, on-body sensor-augmented pump in type 1 diabetes: a multicentre randomised controlled trial","volume":"67","author":"Kim","year":"2024","journal-title":"Diabetologia"},{"key":"2026061813515794000_B12","doi-asserted-by":"crossref","first-page":"2180","DOI":"10.2337\/dc23-0685","article-title":"Safety and efficacy of sustained automated insulin delivery compared with sensor and pump therapy in adults with type 1 diabetes at high risk for hypoglycemia: a randomized controlled trial","volume":"46","author":"Renard","year":"2023","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B13","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1056\/NEJMoa2303911","article-title":"Automated insulin delivery in women with pregnancy complicated by type 1 diabetes","volume":"389","author":"Lee","year":"2023","journal-title":"N Engl J Med"},{"key":"2026061813515794000_B14","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1080\/17434440.2022.2142556","article-title":"Closed-loop insulin delivery: update on the state of the field and emerging technologies","volume":"19","author":"Ware","year":"2022","journal-title":"Expert Rev Med Devices"},{"key":"2026061813515794000_B15","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1089\/dia.2021.0514","article-title":"Current status and emerging options for automated insulin delivery systems","volume":"24","author":"Forlenza","year":"2022","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B16","doi-asserted-by":"crossref","first-page":"S146","DOI":"10.2337\/dc25-S007","article-title":"7. Diabetes technology: Standards of Care in Diabetes\u20142025","volume":"48","author":"American Diabetes Association Professional Practice Committee","year":"2025","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B17","doi-asserted-by":"crossref","first-page":"1406","DOI":"10.1111\/pedi.13421","article-title":"ISPAD clinical practice consensus guidelines 2022: diabetes technologies: insulin delivery","volume":"23","author":"Sherr","year":"2022","journal-title":"Pediatr Diabetes"},{"key":"2026061813515794000_B18","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1056\/NEJMoa2203913","article-title":"Open-source automated insulin delivery in type 1 diabetes","volume":"387","author":"Burnside","year":"2022","journal-title":"N Engl J Med"},{"key":"2026061813515794000_B19","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1089\/dia.2019.0486","article-title":"All insulin pumps are not equivalent: a bench test assessment for several basal rates","volume":"22","author":"Girardot","year":"2020","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B20","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1007\/s00125-024-06308-z","article-title":"The use of automated insulin delivery around physical activity and exercise in type 1 diabetes: a position statement of the European Association for the Study of Diabetes (EASD) and the International Society for Pediatric and Adolescent Diabetes (ISPAD)","volume":"68","author":"Moser","year":"2025","journal-title":"Diabetologia"},{"key":"2026061813515794000_B21","doi-asserted-by":"crossref","first-page":"127","DOI":"10.2337\/dsi22-0018","article-title":"Practical aspects and exercise safety benefits of automated insulin delivery systems in type 1 diabetes","volume":"36","author":"Zaharieva","year":"2023","journal-title":"Diabetes Spectr"},{"key":"2026061813515794000_B22","unstructured":"PANTHER Program\n          . Device comparison chart. Available from https:\/\/www.pantherprogram.org\/device-comparison-chart. Accessed 15 February 2025"},{"key":"2026061813515794000_B23","unstructured":"Medtronic\n          . MiniMed 780G insulin pump. Available from https:\/\/www.medtronic.com\/en-us\/healthcare-professionals\/products\/diabetes\/insulin-pumps\/minimed-780g-insulin-pump.html. Accessed 15 February 2025"},{"key":"2026061813515794000_B24","unstructured":"Tandem Diabetes Care\n          . Watertight rating on the t:slim X2 insulin pump. Available from https:\/\/www.tandemdiabetes.com\/support-center\/pumps-and-supplies\/tslimx2-insulin-pump\/article\/watertight-rating-on-tslimx2. Accessed 15 February 2025"},{"key":"2026061813515794000_B25","unstructured":"Tandem Diabetes Care\n          . Water-resistance rating on the Tandem Mobi system. Available from https:\/\/www.tandemdiabetes.com\/support-center\/pumps-and-supplies\/tandem-mobi-system\/article\/water-resistance-rating-on-tandem-mobi. Accessed 15 February 2025"},{"key":"2026061813515794000_B26","doi-asserted-by":"crossref","first-page":"e148","DOI":"10.2337\/dc23-0470","article-title":"Swimming with the Omnipod 5 automated insulin delivery system: connectivity in the water","volume":"46","author":"Hughes","year":"2023","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B27","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1089\/dia.2022.0562","article-title":"First use of open-source automated insulin delivery AndroidAPS in full closed-loop scenario: Pancreas4ALL randomized pilot study","volume":"25","author":"Petruzelkova","year":"2023","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B28","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.2337\/dci19-0028","article-title":"Clinical targets for continuous glucose monitoring data interpretation: recommendations from the International Consensus on Time in Range","volume":"42","author":"Battelino","year":"2019","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B29","unstructured":"University of Cambridge\n          . US Food and Drug Administration approves Cambridge-developed artificial pancreas. Available from: https:\/\/www.cam.ac.uk\/research\/news\/us-food-and-drug-administration-approves-cambridge-developed-artificial-pancreas. Accessed 16 February 2025"},{"key":"2026061813515794000_B30","doi-asserted-by":"crossref","DOI":"10.1007\/s00592-025-02469-4","article-title":"Case series of a hybrid closed loop therapy system used in pregnancy","author":"Brigham","year":"2025","journal-title":"Acta Diabetol."},{"key":"2026061813515794000_B31","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/S2213-8587(24)00089-5","article-title":"Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trial","volume":"12","author":"Benhalima","year":"2024","journal-title":"Lancet Diabetes Endocrinol"},{"key":"2026061813515794000_B32","doi-asserted-by":"crossref","first-page":"110","DOI":"10.17925\/EE.2024.20.2.14","article-title":"Use of automated insulin delivery in pregnancies complicated by type 1 diabetes","volume":"20","author":"Chillakanti","year":"2024","journal-title":"touchREV Endocrinol"},{"key":"2026061813515794000_B33","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/S2213-8587(23)00116-X","article-title":"Management of type 1 diabetes in pregnancy: update on lifestyle, pharmacological treatment, and novel technologies for achieving glycaemic targets","volume":"11","author":"Benhalima","year":"2023","journal-title":"Lancet Diabetes Endocrinol"},{"key":"2026061813515794000_B34","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1089\/dia.2022.0540","article-title":"Expert guidance on off-label use of hybrid closed-loop therapy in pregnancies complicated by diabetes","volume":"25","author":"Szmuilowicz","year":"2023","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B35","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1177\/193229681200600429","article-title":"Insulin infusion set: the Achilles heel of continuous subcutaneous insulin infusion","volume":"6","author":"Heinemann","year":"2012","journal-title":"J Diabetes Sci Technol"},{"key":"2026061813515794000_B36","doi-asserted-by":"crossref","unstructured":"Nguyen\n              KT\n            , XuNY, BuckinghamBA, . Improving the patient experience with longer wear infusion sets symposium report. J Diabetes Sci Technol2022;16:775\u2013782","DOI":"10.1177\/19322968221078884"},{"key":"2026061813515794000_B37","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1177\/19322968221112120","article-title":"Development of the extended infusion set and its mechanism of action","volume":"18","author":"Zhang","year":"2024","journal-title":"J Diabetes Sci Technol"},{"key":"2026061813515794000_B38","doi-asserted-by":"crossref","first-page":"1973","DOI":"10.1111\/dom.14395","article-title":"Longevity of the novel ConvaTec infusion set with Lantern technology","volume":"23","author":"Lal","year":"2021","journal-title":"Diabetes Obes Metab"},{"key":"2026061813515794000_B39","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1007\/s11892-022-01469-w","article-title":"Barriers and facilitators to diabetes device adoption for people with type 1 diabetes","volume":"22","author":"Tanenbaum","year":"2022","journal-title":"Curr Diab Rep"},{"key":"2026061813515794000_B40","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1089\/dia.2022.0201.pub","article-title":"Positive impact of the bionic pancreas on diabetes control in youth 6\u201317 years old with type 1 diabetes: a multicenter randomized trial","volume":"24","author":"Messer","year":"2022","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B41","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1089\/dia.2023.0238","article-title":"Psychosocial impact of the insulin-only iLet bionic pancreas for adults, youth, and caregivers of youth with type 1 diabetes","volume":"25","author":"Weissberg-Benchell","year":"2023","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B42","doi-asserted-by":"crossref","first-page":"2034","DOI":"10.1007\/s00125-024-06165-w","article-title":"The role of automated insulin delivery technology in diabetes","volume":"67","author":"Boughton","year":"2024","journal-title":"Diabetologia"},{"key":"2026061813515794000_B43","doi-asserted-by":"crossref","first-page":"1667","DOI":"10.1111\/dom.14737","article-title":"Smartwatch gesture-based meal reminders improve glycaemic control","volume":"24","author":"Corbett","year":"2022","journal-title":"Diabetes Obes Metab"},{"key":"2026061813515794000_B44","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1056\/NEJMoa1805233","article-title":"Closed-loop insulin delivery for glycemic control in noncritical care","volume":"379","author":"Bally","year":"2018","journal-title":"N Engl J Med"},{"key":"2026061813515794000_B45","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/S2213-8587(19)30061-0","article-title":"Fully closed-loop insulin delivery in inpatients receiving nutritional support: a two-centre, open-label, randomised controlled trial","volume":"7","author":"Boughton","year":"2019","journal-title":"Lancet Diabetes Endocrinol"},{"key":"2026061813515794000_B46","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1038\/s41591-022-02144-z","article-title":"Fully automated closed-loop insulin delivery in adults with type 2 diabetes: an open-label, single-center, randomized crossover trial","volume":"29","author":"Daly","year":"2023","journal-title":"Nat Med"},{"key":"2026061813515794000_B47","doi-asserted-by":"crossref","first-page":"1916","DOI":"10.2337\/dc23-0728","article-title":"Fully closed-loop glucose control compared with insulin pump therapy with continuous glucose monitoring in adults with type 1 diabetes and suboptimal glycemic control: a single-center, randomized, crossover study","volume":"46","author":"Boughton","year":"2023","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B48","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.2337\/dc23-0119","article-title":"Assessment of meal anticipation for improving fully automated insulin delivery in adults with type 1 diabetes","volume":"46","author":"Garcia-Tirado","year":"2023","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B49","unstructured":"Tandem Diabetes Care\n          . Tandem Diabetes Care enters multi-year research collaboration with UVA Center for Diabetes Technology for development of advanced insulin delivery systems. Available from https:\/\/investor.tandemdiabetes.com\/news-releases\/news-release-details\/tandem-diabetes-care-enters-multi-year-research-collaboration. Accessed 7 February 2025"},{"key":"2026061813515794000_B50","doi-asserted-by":"crossref","DOI":"10.1089\/dia.2023.0293","article-title":"(Hybrid) closed-loop systems: from announced to unannounced exercise","author":"Zimmer","year":"2023","journal-title":"Diabetes Technol Ther."},{"key":"2026061813515794000_B51","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.2337\/dc08-0720","article-title":"Barriers to physical activity among patients with type 1 diabetes","volume":"31","author":"Brazeau","year":"2008","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B52","doi-asserted-by":"crossref","first-page":"2045","DOI":"10.1007\/s00125-024-06229-x","article-title":"Applying technologies to simplify strategies for exercise in type 1 diabetes","volume":"67","author":"Perkins","year":"2024","journal-title":"Diabetologia"},{"key":"2026061813515794000_B53","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1177\/19322968221088327","article-title":"Strengths and challenges of closed-loop insulin delivery during exercise in people with type 1 diabetes: potential future directions","volume":"17","author":"Paldus","year":"2023","journal-title":"J Diabetes Sci Technol"},{"key":"2026061813515794000_B54","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4103\/2230-973X.176456","article-title":"Insulin delivery methods: past, present and future","volume":"6","author":"Shah","year":"2016","journal-title":"Int J Pharm Investig"},{"key":"2026061813515794000_B55","doi-asserted-by":"crossref","first-page":"691","DOI":"10.2337\/diab.25.8.691","article-title":"Comparison of peripheral and portal routes of insulin infusion by a computer-controlled insulin infusion system (artificial endocrine pancreas)","volume":"25","author":"Botz","year":"1976","journal-title":"Diabetes"},{"key":"2026061813515794000_B56","first-page":"738","article-title":"Peritoneal and subcutaneous absorption of insulin in type I diabetic subjects","volume":"77","author":"Giacca","year":"1993","journal-title":"J Clin Endocrinol Metab"},{"key":"2026061813515794000_B57","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1111\/cen.12546","article-title":"Intraperitoneal insulin infusion: treatment option for type 1 diabetes resulting in beneficial endocrine effects beyond glycaemia","volume":"81","author":"van Dijk","year":"2014","journal-title":"Clin Endocrinol (Oxf)"},{"key":"2026061813515794000_B58","first-page":"118","article-title":"Continuous intraperitoneal insulin infusion partly restores the glucagon response to hypoglycaemia in type 1 diabetic patients","volume":"26","author":"Oskarsson","year":"2000","journal-title":"Diabetes Metab"},{"key":"2026061813515794000_B59","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1053\/meta.2000.7727","article-title":"Increased responses of glucagon and glucose production to hypoglycemia with intraperitoneal versus subcutaneous insulin treatment","volume":"49","author":"Wan","year":"2000","journal-title":"Metabolism"},{"key":"2026061813515794000_B60","first-page":"491","article-title":"Metabolic and hormonal responses to exercise in type 1 diabetic patients during continuous subcutaneous, as compared to continuous intraperitoneal, insulin infusion","volume":"25","author":"Oskarsson","year":"1999","journal-title":"Diabetes Metab"},{"key":"2026061813515794000_B61","doi-asserted-by":"crossref","first-page":"53","DOI":"10.2337\/diacare.15.1.53","article-title":"Randomized comparison of metabolic control achieved by intraperitoneal insulin infusion with implantable pumps versus intensive subcutaneous insulin therapy in type I diabetic patients","volume":"15","author":"Selam","year":"1992","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B62","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.2337\/dc08-2340","article-title":"Improved glycemic control with intraperitoneal versus subcutaneous insulin in type 1 diabetes: a randomized controlled trial","volume":"32","author":"Logtenberg","year":"2009","journal-title":"Diabetes Care"},{"key":"2026061813515794000_B63","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1111\/j.1463-1326.2009.01059.x","article-title":"A reduction in severe hypoglycaemia in type 1 diabetes in a randomized crossover study of continuous intraperitoneal compared with subcutaneous insulin infusion","volume":"11","author":"Liebl","year":"2009","journal-title":"Diabetes Obes Metab"},{"key":"2026061813515794000_B64","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s00423-008-0437-9","article-title":"Surgical aspects and complications of continuous intraperitoneal insulin infusion with an implantable pump","volume":"395","author":"Haveman","year":"2010","journal-title":"Langenbecks Arch Surg"},{"key":"2026061813515794000_B65","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1056\/NEJMoa0810625","article-title":"Intensive versus conventional glucose control in critically ill patients","volume":"360","author":"NICE-SUGAR Study Investigators; Finfer","year":"2009","journal-title":"N Engl J Med"},{"key":"2026061813515794000_B66","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1001\/jama.300.8.933","article-title":"Benefits and risks of tight glucose control in critically ill adults: a meta-analysis","volume":"300","author":"Wiener","year":"2008","journal-title":"JAMA"},{"key":"2026061813515794000_B67","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1089\/dia.2023.0304","article-title":"Automated insulin delivery with remote real-time continuous glucose monitoring for hospitalized patients with diabetes: a multicenter, single-arm, feasibility trial","volume":"25","author":"Davis","year":"2023","journal-title":"Diabetes Technol Ther"},{"key":"2026061813515794000_B68","doi-asserted-by":"crossref","first-page":"742","DOI":"10.2337\/dc22-1915","article-title":"Safety and efficacy of the Omnipod 5 automated insulin delivery system in adults with type 2 diabetes: from injections to hybrid closed-loop therapy","volume":"46","author":"Davis","year":"2023","journal-title":"Diabetes Care"}],"container-title":["Diabetes Spectrum"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/diabetesjournals.org\/spectrum\/article-pdf\/38\/3\/217\/838829\/diaspectdsi250003.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/diabetesjournals.org\/spectrum\/article-pdf\/38\/3\/217\/838829\/diaspectdsi250003.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T17:52:13Z","timestamp":1781805133000},"score":1,"resource":{"primary":{"URL":"https:\/\/diabetesjournals.org\/spectrum\/article\/38\/3\/217\/163136\/Automated-Insulin-Delivery-for-Type-1-Diabetes"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,1]]},"references-count":68,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,8,15]]},"published-print":{"date-parts":[[2025,8,1]]}},"URL":"https:\/\/doi.org\/10.2337\/dsi25-0003","relation":{},"ISSN":["1040-9165","1944-7353"],"issn-type":[{"value":"1040-9165","type":"print"},{"value":"1944-7353","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,1]]}}}