{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T02:53:22Z","timestamp":1788576802010,"version":"build-2803163510"},"reference-count":26,"publisher":"Operative Dentistry","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008,1,1]]},"abstract":"<jats:title>Clinical Relevance<\/jats:title>\n               <jats:p>The results of this study indicate that preheating composites can improve adaptation of resin composites to tooth structure. This technique significantly reduced microleakage. However, delaying light curing of the preheated composite after placement appears to be counterproductive and diminishes the positive effects from the preheating treatment. Flowable liner was less effective than preheating the composite in reducing microleakage.<\/jats:p>","DOI":"10.2341\/07-41","type":"journal-article","created":{"date-parts":[[2008,1,10]],"date-time":"2008-01-10T12:16:22Z","timestamp":1199967382000},"page":"72-78","source":"Crossref","is-referenced-by-count":86,"title":["Effect of Pre-heating Resin Composite on Restoration Microleakage"],"prefix":"10.2341","volume":"33","author":[{"given":"W. C.","family":"Wagner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. N.","family":"Aksu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. L.","family":"Neme","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. B.","family":"Linger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F. E.","family":"Pink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Walker","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1188","published-online":{"date-parts":[[2008,1,1]]},"reference":[{"issue":"2","key":"2020060500130877600_i1559-2863-33-1-72-b1","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.prosdent.2004.11.006","article-title":"Relative wear of flowable and highly filled composite.","volume":"93","author":"Clelland","year":"2005","journal-title":"The Journal of Prosthetic Dentistry"},{"issue":"2","key":"2020060500130877600_i1559-2863-33-1-72-b2","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1007\/s00784-005-0311-x","article-title":"In vivo interfacial adaptation of Class II resin composite restorations with and without a flowable resin composite liner.","volume":"9","author":"Lindberg","year":"2005","journal-title":"Clinical Oral Investigations"},{"issue":"1","key":"2020060500130877600_i1559-2863-33-1-72-b3","first-page":"32","article-title":"Influence of flowable liner and margin location on microleakage of conventional and packable Class II resin composites.","volume":"30","author":"Tredwin","year":"2005","journal-title":"Operative Dentistry"},{"issue":"6","key":"2020060500130877600_i1559-2863-33-1-72-b4","first-page":"713","article-title":"The effect of flowable resin composite on microleakage and internal voids in Class II composite restorations.","volume":"29","author":"Olmez","year":"2004","journal-title":"Operative Dentistry"},{"issue":"1","key":"2020060500130877600_i1559-2863-33-1-72-b5","first-page":"33","article-title":"Microleakage of cervical cavities restored with flowable composites.","volume":"17","author":"Kubo","year":"2004","journal-title":"American Journal of Dentistry"},{"issue":"2","key":"2020060500130877600_i1559-2863-33-1-72-b6","first-page":"84","article-title":"Effects of lining materials on microleakage and internal voids of Class II resin-based composite restorations.","volume":"16","author":"Chuang","year":"2003","journal-title":"American Journal of Dentistry"},{"issue":"6","key":"2020060500130877600_i1559-2863-33-1-72-b7","first-page":"600","article-title":"Microleakage of Class II packable resin composites lined with flowables: An in vitro study.","volume":"27","author":"Neme","year":"2002","journal-title":"Operative Dentistry"},{"issue":"Special Issue","key":"2020060500130877600_i1559-2863-33-1-72-b8","article-title":"Composite film thickness at various temperatures.","volume":"83","author":"Holmes","year":"2004","journal-title":"Journal of Dental Research"},{"issue":"5","key":"2020060500130877600_i1559-2863-33-1-72-b9","first-page":"1","article-title":"Warming up to composites.","volume":"25","author":"Freedman","year":"2004","journal-title":"Compendium"},{"issue":"11","key":"2020060500130877600_i1559-2863-33-1-72-b10","first-page":"20","article-title":"A new technique for placement of posterior composite.","volume":"21","author":"Trushkowsky","year":"2002","journal-title":"Dentistry Today"},{"issue":"4","key":"2020060500130877600_i1559-2863-33-1-72-b11","article-title":"Effects of preheating resin composite on flowability.","author":"Broome","year":"2006","journal-title":"The Dental Advisor"},{"issue":"3","key":"2020060500130877600_i1559-2863-33-1-72-b12","first-page":"161","article-title":"Preheating composite resin: A clinical perspective.","volume":"19","author":"Deliperi","year":"2007","journal-title":"Practical Proceedings & Aesthetic Dentistry"},{"issue":"6","key":"2020060500130877600_i1559-2863-33-1-72-b13","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1111\/j.1708-8240.2006.00046.x","article-title":"Clinically relevant issues related to preheating composites.","volume":"18","author":"Daronch","year":"2006","journal-title":"Journal of Esthetic Restorative Dentistry"},{"issue":"1","key":"2020060500130877600_i1559-2863-33-1-72-b14","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/S0109-5641(01)00020-3","article-title":"Porosities and voids in Class I restorations placed by six operators using a packable or syringable composite.","volume":"18","author":"Opdam","year":"2002","journal-title":"Dental Materials"},{"issue":"4","key":"2020060500130877600_i1559-2863-33-1-72-b15","first-page":"171","article-title":"Reducing microleakage in composite resin restorations: An in vitro study.","volume":"11","author":"Unlu","year":"2003","journal-title":"European Journal of Prosthodontic Restorative Dentistry"},{"issue":"5","key":"2020060500130877600_i1559-2863-33-1-72-b16","doi-asserted-by":"crossref","first-page":"567","DOI":"10.14219\/jada.archive.1998.0274","article-title":"A characterization of first-generation flowable composites.","volume":"129","author":"Bayne","year":"1998","journal-title":"Journal of the American Dental Association"},{"issue":"6","key":"2020060500130877600_i1559-2863-33-1-72-b17","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.prosdent.2006.09.022","article-title":"Effect of temperature on unpolymerized composite resin film thickness.","volume":"96","author":"Blalock","year":"2006","journal-title":"Journal of Prosthetic Dentistry"},{"issue":"3","key":"2020060500130877600_i1559-2863-33-1-72-b18","first-page":"169","article-title":"Improving the polymerization of composite resins.","volume":"18","author":"Conditt","year":"2006","journal-title":"Practical Procedures in Aesthetic Dentistry"},{"issue":"1","key":"2020060500130877600_i1559-2863-33-1-72-b19","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1177\/154405910608500106","article-title":"Polymerization kinetic of pre-heated composite.","volume":"85","author":"Daronch","year":"2006","journal-title":"Journal of Dental Research"},{"issue":"7","key":"2020060500130877600_i1559-2863-33-1-72-b20","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1177\/154405910508400716","article-title":"Monomer conversion of pre-heated composite.","volume":"84","author":"Daronch","year":"2005","journal-title":"Journal of Dental Research"},{"issue":"Special Issue A","key":"2020060500130877600_i1559-2863-33-1-72-b21","article-title":"Curing efficiency of a direct composite at different temperatures.","volume":"82","author":"Littlejohn","year":"2003","journal-title":"Journal of Dental Research"},{"issue":"Special Issue A","key":"2020060500130877600_i1559-2863-33-1-72-b22","article-title":"Influence of initiator system and temperature on real time double bond conversion.","volume":"82","author":"Vogel","year":"2003","journal-title":"Journal of Dental Research"},{"issue":"8","key":"2020060500130877600_i1559-2863-33-1-72-b23","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.dental.2004.02.003","article-title":"Use of near-IR to monitor the influence of external heating on dental composite photopolymerization.","volume":"20","author":"Trujillo","year":"2004","journal-title":"Dental Materials"},{"issue":"Special Issue A","key":"2020060500130877600_i1559-2863-33-1-72-b24","article-title":"Effect of preheating on the hardness of two resin composite materials.","volume":"82","author":"Wagner","year":"2003","journal-title":"Journal of Dental Research"},{"issue":"Special Issue A","key":"2020060500130877600_i1559-2863-33-1-72-b25","article-title":"The effect of temperature on hardness of a light-curing composite.","volume":"82","author":"Bortolotto","year":"2003","journal-title":"Journal of Dental Research"},{"issue":"3","key":"2020060500130877600_i1559-2863-33-1-72-b26","doi-asserted-by":"crossref","first-page":"12","DOI":"10.5005\/jcdp-7-3-12","article-title":"The effects of temperature and light intensity on the polymerization shrinkage of light-cured composite filling materials.","volume":"7","author":"Elhejazi","year":"2006","journal-title":"The Journal of Contemporary Dental Practice"}],"container-title":["Operative Dentistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/meridian.allenpress.com\/operative-dentistry\/article-pdf\/33\/1\/72\/1821095\/07-41.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/meridian.allenpress.com\/operative-dentistry\/article-pdf\/33\/1\/72\/1821095\/07-41.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T13:28:03Z","timestamp":1755264483000},"score":1,"resource":{"primary":{"URL":"https:\/\/operative-dentistry.kglmeridian.com\/view\/journals\/odnt\/33\/1\/article-p72.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,1,1]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2008,1,1]]},"published-print":{"date-parts":[[2008,1,1]]}},"URL":"https:\/\/doi.org\/10.2341\/07-41","relation":{},"ISSN":["1559-2863","0361-7734"],"issn-type":[{"value":"1559-2863","type":"electronic"},{"value":"0361-7734","type":"print"}],"subject":[],"published":{"date-parts":[[2008,1,1]]}}}