{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T18:22:45Z","timestamp":1761675765803},"reference-count":8,"publisher":"American Dental Society of Anesthesiology (ADSA)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008]]},"abstract":"<jats:title>Abstract<\/jats:title>\n        <jats:p>The Airtraq laryngoscope is a new intubation device that provides a non\u2013line-of-sight view of the glottis. We evaluated this device by comparing the ease of nasotracheal intubation on a manikin with the use of Airtraq versus the Macintosh laryngoscope with and without Magill forceps. Nasotracheal intubation on a manikin was performed by 20 anesthesiologists and 20 residents with the Airtraq or Macintosh laryngoscope. The mean (\u00b1 SD) time required for nasotracheal intubation by the residents was significantly shorter with the Airtraq laryngoscope than with the Macintosh laryngoscope (16 \u00b1 7 sec vs 22 \u00b1 10 sec; <jats:italic>P<\/jats:italic> &lt; .001), but no difference in intubation time was observed between Airtraq (15 \u00b1 11 sec) and Macintosh (13 \u00b1 6 sec) laryngoscopy by the anesthesiologists. The Magill forceps was used more frequently to facilitate intubation with the Macintosh laryngoscope than with the Airtraq laryngoscope in both groups of operators 7(<jats:italic>P<\/jats:italic> &lt; .001). The Airtraq laryngoscope scored better on the visual analog scale than did the Macintosh laryngoscope in both groups of operators (<jats:italic>P<\/jats:italic> &lt; .05). The Airtraq laryngoscope offers potential advantages over standard direct laryngoscopy for nasotracheal intubation.<\/jats:p>","DOI":"10.2344\/0003-3006-55.3.78","type":"journal-article","created":{"date-parts":[[2010,6,11]],"date-time":"2010-06-11T19:07:33Z","timestamp":1276283253000},"page":"78-81","source":"Crossref","is-referenced-by-count":12,"title":["Nasotracheal Intubation Using the Airtraq Versus Macintosh Laryngoscope: A Manikin Study"],"prefix":"10.2344","volume":"55","author":[{"given":"Yoshihiro","family":"Hirabayashi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norimasa","family":"Seo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1191","reference":[{"key":"i0003-3006-55-3-78-Maharaj1","series-title":"Anaesthesia","first-page":"469","article-title":"Evaluation of intubation using the Airtraq\u00ae or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy\u2014a manikin study.","volume":"61","author":"Maharaj, C. H.","year":"2006","unstructured":"Maharaj, C. H., B. D.Higgins, B. H.Harte, and J. G.Laffey. Evaluation of intubation using the Airtraq\u00ae or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy\u2014a manikin study.Anaesthesia2006. 61:469\u2013477."},{"key":"i0003-3006-55-3-78-Maharaj2","series-title":"Anaesthesia","first-page":"671","article-title":"Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq\u00ae and Macintosh laryngoscope.","volume":"61","author":"Maharaj, C. H.","year":"2006","unstructured":"Maharaj, C. H., J. F.Costello, B. D.Higgins, B. H.Harte, and J. G.Laffey. Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq\u00ae and Macintosh laryngoscope.Anaesthesia2006. 61:671\u2013677."},{"key":"i0003-3006-55-3-78-Maharaj3","series-title":"Anaesthesia","first-page":"1093","article-title":"A comparison of tracheal intubation using the Airtraq\u00ae or the Macintosh laryngoscope in routine airway management: a randomized, controlled clinical trial.","volume":"61","author":"Maharaj, C. H.","year":"2006","unstructured":"Maharaj, C. H., D.O'Croinin, G.Curley, B. H.Harte, and J. G.Laffey. A comparison of tracheal intubation using the Airtraq\u00ae or the Macintosh laryngoscope in routine airway management: a randomized, controlled clinical trial.Anaesthesia2006. 61:1093\u20131099."},{"key":"i0003-3006-55-3-78-Maharaj4","series-title":"Am J Emerg Med","first-page":"769","article-title":"Tracheal intubation by inexperienced medical residents using the Airtraq and Macintosh laryngoscopes\u2014a manikin study.","volume":"24","author":"Maharaj, C. H.","year":"2006","unstructured":"Maharaj, C. H., M. N.Chonghaile, B. D.Higgins, B. H.Harte, and J. G.Laffey. Tracheal intubation by inexperienced medical residents using the Airtraq and Macintosh laryngoscopes\u2014a manikin study.Am J Emerg Med2006. 24:769\u2013774."},{"key":"i0003-3006-55-3-78-Shigematsu1","series-title":"Can J Anaesth","first-page":"798","article-title":"Nasotracheal intubation using Bullard laryngoscope.","volume":"38","author":"Shigematsu, T.","year":"1991","unstructured":"Shigematsu, T., N.Miyazawa, and T.Yorozu. Nasotracheal intubation using Bullard laryngoscope.Can J Anaesth1991. 38:798."},{"key":"i0003-3006-55-3-78-Shigematsu2","series-title":"Anesth Analg","first-page":"132","article-title":"Nasal intubation with Bullard laryngoscope: a useful approach for difficult airways.","volume":"79","author":"Shigematsu, T.","year":"1994","unstructured":"Shigematsu, T., N.Miyazawa, M.Kobayashi, T.Yorozu, Y.Toyoda, and H.Morisaki. Nasal intubation with Bullard laryngoscope: a useful approach for difficult airways.Anesth Analg1994. 79:132\u2013135."},{"key":"i0003-3006-55-3-78-Xue1","series-title":"J Clin Anesth","first-page":"611","article-title":"A clinical assessment of the Glidescope videolaryngoscope in nasotracheal intubation with general anesthesia.","volume":"8","author":"Xue, F.","year":"2006","unstructured":"Xue, F., G.Zhang, J.Liu, et al. A clinical assessment of the Glidescope videolaryngoscope in nasotracheal intubation with general anesthesia.J Clin Anesth2006. 8:611\u2013615."},{"key":"i0003-3006-55-3-78-Hirabayashi1","series-title":"Can J Anaesth","first-page":"1163","article-title":"GlideScope\u00ae videolaryngoscope facilitates nasotracheal intubation.","volume":"53","author":"Hirabayashi, Y.","year":"2006","unstructured":"Hirabayashi, Y.\n          \n          GlideScope\u00ae videolaryngoscope facilitates nasotracheal intubation.\n          Can J Anaesth\n          2006. 53:1163\u20131164."}],"container-title":["Anesthesia Progress"],"original-title":[],"link":[{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/55\/3\/article-p78.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/anesthesia-progress\/article-pdf\/55\/3\/78\/2100533\/0003-3006-55_3_78.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/55\/3\/article-p78.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/55\/3\/article-p78.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T12:19:39Z","timestamp":1728303579000},"score":1,"resource":{"primary":{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/55\/3\/article-p78.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008]]},"references-count":8,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.2344\/0003-3006-55.3.78","relation":{},"ISSN":["0003-3006","1878-7177"],"issn-type":[{"type":"print","value":"0003-3006"},{"type":"electronic","value":"1878-7177"}],"subject":[],"published":{"date-parts":[[2008]]}}}