{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,8]],"date-time":"2024-10-08T04:15:14Z","timestamp":1728360914197},"reference-count":8,"publisher":"American Dental Society of Anesthesiology (ADSA)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013]]},"abstract":"<jats:title>Abstract<\/jats:title>\n        <jats:p>The Parker Flex-Tip tracheal tube (PFTT, Parker Medical, Highlands Ranch, Colo) has a soft, flexible, curved tip with double Murphy eyes. Previous studies have shown that the PFTT reduces the incidence of epistaxis during nasotracheal intubation and the incidence of postintubation nasal pain, as compared to conventional tracheal tubes. Although thermosoftening is a well-known and effective technique for reducing epistaxis during nasotracheal intubation with conventional tracheal tubes, we occasionally encounter difficulties with advancing the tube through the nasal passage when the PFTT is thermosoftened prior to nasotracheal intubation. Consequently, when using the PFTT for nasotracheal intubation, the procedure of thermosoftening should be avoided.<\/jats:p>","DOI":"10.2344\/0003-3006-60.3.109","type":"journal-article","created":{"date-parts":[[2013,9,6]],"date-time":"2013-09-06T18:59:41Z","timestamp":1378493981000},"page":"109-110","source":"Crossref","is-referenced-by-count":2,"title":["Thermosoftening of the Parker Flex-TipTM Tracheal Tube in Preparation for Nasotracheal Intubation"],"prefix":"10.2344","volume":"60","author":[{"given":"Takuro","family":"Sanuki","sequence":"first","affiliation":[{"name":"Assistant Professor, Department of Anesthesiology, Osaka Dental University, Osaka, Japan and Visting Professor, Department of Anesthesiology, University of Pittsburgh, Pittsburgh, Pennsylvania"},{"name":"Professor, Department of Anesthesiology, Osaka Dental University, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junichiro","family":"Kotani","sequence":"additional","affiliation":[{"name":"Professor, Department of Anesthesiology, Osaka Dental University, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1191","reference":[{"key":"i0003-3006-60-3-109-b01","series-title":"Anaesthesia","first-page":"249","article-title":"Nasotracheal intubation for head and neck surgery","volume":"58","author":"Hall\n              CE,","year":"2003","unstructured":"Hall\n              CE, \n            \n              Shutt\n              LE. \n          \n          Nasotracheal intubation for head and neck surgery. Anaesthesia. 2003;58:249\u2013256."},{"key":"i0003-3006-60-3-109-b02","series-title":"Anesthesiology","first-page":"51","article-title":"Nasotracheal intubation: a randomized trial of two methods","volume":"96","author":"Elwood\n              T,","year":"2002","unstructured":"Elwood\n              T, \n            \n              Stillions\n              DM, \n            \n              Woo\n              DW, \n            \n              Bradford\n              HM, \n            \n              Ramamoorthy\n              C. \n          \n          Nasotracheal intubation: a randomized trial of two methods. Anesthesiology. 2002;96:51\u201353."},{"key":"i0003-3006-60-3-109-b03","series-title":"Anesth Prog","first-page":"18","article-title":"Parker flex-tip and standard-tip endotracheal tubes: a comparison during nasotracheal intubation","volume":"57","author":"Prior\n              S,","year":"2010","unstructured":"Prior\n              S, \n            \n              Heaton\n              J, \n            \n              Jatana\n              KR, \n            \n              Rashid\n              RG. \n          \n          Parker flex-tip and standard-tip endotracheal tubes: a comparison during nasotracheal intubation. Anesth Prog. 2010;57:18\u201324."},{"key":"i0003-3006-60-3-109-b04","series-title":"Anaesthesia","first-page":"8","article-title":"The Parker Flex-Tip tube for nasotracheal intubation: the influence on nasal mucosal trauma","volume":"65","author":"Sanuki\n              T,","year":"2010","unstructured":"Sanuki\n              T, \n            \n              Hirokane\n              M, \n            \n              Matsuda\n              Y, \n            \n              Sugioka\n              S, \n            \n              Kotani\n              J. \n          \n          The Parker Flex-Tip tube for nasotracheal intubation: the influence on nasal mucosal trauma. Anaesthesia. 2010;65:8\u201311."},{"key":"i0003-3006-60-3-109-b05","series-title":"Anesth Analg","first-page":"698","article-title":"Thermosoftening treatment of the nasotracheal tube before intubation can reduce epistaxis and nasal damage","volume":"91","author":"Kim\n              YC,","year":"2000","unstructured":"Kim\n              YC, \n            \n              Lee\n              SH, \n            \n              Noh\n              GJ, \n            et al\n          . Thermosoftening treatment of the nasotracheal tube before intubation can reduce epistaxis and nasal damage. Anesth Analg. 2000;91:698\u2013701."},{"key":"i0003-3006-60-3-109-b06","series-title":"Anesth Analg","first-page":"1358","article-title":"The EndoFlex tube enhances navigability through the nasal cavity during nasotracheal intubation","volume":"108","author":"Sugiyama\n              K,","year":"2009","unstructured":"Sugiyama\n              K, \n            \n              Takahashi\n              N, \n            \n              Kohjitani\n              A. \n          \n          The EndoFlex tube enhances navigability through the nasal cavity during nasotracheal intubation. Anesth Analg. 2009;108:1358\u20131359."},{"key":"i0003-3006-60-3-109-b07","series-title":"Journal of Osaka Dental University","first-page":"237","article-title":"Mechanical characteristics of bending in endotracheal tubes","volume":"45","author":"Daigo\n              E,","year":"2011","unstructured":"Daigo\n              E, \n            \n              Sakuma\n              Y, \n            \n              Kato\n              Y, \n            \n              Kotani\n              J. \n          \n          Mechanical characteristics of bending in endotracheal tubes. Journal of Osaka Dental University. 2011;45:237\u2013240."},{"key":"i0003-3006-60-3-109-b08","series-title":"Anaesthesia","first-page":"417","article-title":"The Parker Flex-Tip tube for nasotracheal intubation","volume":"65","author":"Xue\n              FS,","year":"2010","unstructured":"Xue\n              FS, \n            \n              Xiong\n              J, \n            \n              Yuan\n              YJ, \n            \n              Wang\n              Q. \n          \n          The Parker Flex-Tip tube for nasotracheal intubation. Anaesthesia. 2010;65:417."}],"container-title":["Anesthesia Progress"],"original-title":[],"link":[{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/60\/3\/article-p109.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/anesthesia-progress\/article-pdf\/60\/3\/109\/2101418\/0003-3006-60_3_109.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/60\/3\/article-p109.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/60\/3\/article-p109.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T12:24:49Z","timestamp":1728303889000},"score":1,"resource":{"primary":{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/60\/3\/article-p109.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"references-count":8,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.2344\/0003-3006-60.3.109","relation":{},"ISSN":["0003-3006","1878-7177"],"issn-type":[{"type":"print","value":"0003-3006"},{"type":"electronic","value":"1878-7177"}],"subject":[],"published":{"date-parts":[[2013]]}}}