{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T01:10:16Z","timestamp":1733274616706,"version":"3.30.1"},"reference-count":19,"publisher":"American Dental Society of Anesthesiology (ADSA)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:sec>\n<jats:title>Objective<\/jats:title>\n<jats:p>Previous studies have reported that the noise generated by dental equipment can interfere with the auscultation of respiratory sounds during sedation. Therefore, this study aimed to identify whether positing the acoustic sensor on the chest or cervical position would be least susceptible to interference from dental suction device noise, a prominent noise noted during respiratory sound monitoring during dental sedation.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>This prospective cohort study was conducted with 30 students. Sound intensity (dB) and frequency (kHz) levels from the dental suction were recorded from the cervical and chest regions under both oral and nasal breathing conditions and analyzed.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The mean intensity of dental suction sounds was significantly lower in the chest region compared with the cervical region, regardless of the breathing condition (<jats:italic>P<\/jats:italic> &lt; .001). Furthermore, in the chest region, the mean sound frequency during oral breathing was significantly lower than that during nasal breathing (<jats:italic>P<\/jats:italic> &lt; .01).<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Our study suggests that monitoring respiratory sounds in the chest region can significantly reduce interference from noise generated by dental suction devices compared with monitoring at the cervical region.<\/jats:p>\n<\/jats:sec>","DOI":"10.2344\/23-00017","type":"journal-article","created":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T00:30:31Z","timestamp":1733272231000},"page":"171-175","source":"Crossref","is-referenced-by-count":0,"title":["Dental Suction Interference and Acoustic Respiratory Monitoring"],"prefix":"10.2344","volume":"71","author":[{"given":"Eimi","family":"Tabata","sequence":"first","affiliation":[{"name":"School of Dentistry, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshitaka","family":"Shimizu","sequence":"additional","affiliation":[{"name":"Department of Dental Anesthesiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kana","family":"Oue","sequence":"additional","affiliation":[{"name":"Section of Dental Anesthesiology, Department of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noboru","family":"Saeki","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care, Hiroshima University, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichiro","family":"Ohshimo","sequence":"additional","affiliation":[{"name":"Department of Emergency and Critical Care Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akari","family":"Mukai","sequence":"additional","affiliation":[{"name":"Department of Dental Anesthesiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hitomi","family":"Ishikawa","sequence":"additional","affiliation":[{"name":"Section of Dental Anesthesiology, Department of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hisanobu","family":"Kamio","sequence":"additional","affiliation":[{"name":"Section of Dental Anesthesiology, Department of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsuhiro","family":"Yoshida","sequence":"additional","affiliation":[{"name":"Section of Dental Anesthesiology, Department of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuaki","family":"Shime","sequence":"additional","affiliation":[{"name":"Department of Emergency and Critical Care Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1191","reference":[{"key":"i1878-7177-71-4-171-b01","series-title":"Anesthesiology","first-page":"437","article-title":"Practice guidelines for moderate procedural sedation and analgesia 2018: a report by the American Society of Anesthesiologists Task Force on Moderate Procedural Sedation and Analgesia, the American Association of Oral and Maxillofacial Surgeons, American College of Radiology, American Dental Association, American Society of Dentist Anesthesiologists, and Society of Interventional Radiology","volume":"128","year":"2018","unstructured":"Practice guidelines for moderate procedural sedation and analgesia 2018: a report by the American Society of Anesthesiologists Task Force on Moderate Procedural Sedation and Analgesia, the American Association of Oral and Maxillofacial Surgeons, American College of Radiology, American Dental Association, American Society of Dentist Anesthesiologists, and Society of Interventional Radiology. Anesthesiology. 2018;128:437\u2013479."},{"key":"i1878-7177-71-4-171-b02","series-title":"Anesth Prog","first-page":"e1","article-title":"Practice guidelines for intravenous conscious sedation in dentistry (Second Edition, 2017)","volume":"65","author":"Working Group on Guidelines Development for Intravenous Sedation in Dentistry, the Japanese Dental Society of Anesthesiology","year":"2018","unstructured":"Working Group on Guidelines Development for Intravenous Sedation in Dentistry, the Japanese Dental Society of Anesthesiology. Practice guidelines for intravenous conscious sedation in dentistry (Second Edition, 2017). Anesth Prog. 2018;65:e1\u2013e18."},{"key":"i1878-7177-71-4-171-b03","series-title":"Can J Anaesth","first-page":"1372","article-title":"Procedural sedation: a position paper of the Canadian Anesthesiologists\u2019 Society","volume":"65","author":"Dobson G,","year":"2018","unstructured":"Dobson G,\nChong MA,\nChow L, et al. Procedural sedation: a position paper of the Canadian Anesthesiologists\u2019 Society. Can J Anaesth. 2018;65:1372\u20131384."},{"key":"i1878-7177-71-4-171-b04","series-title":"Eur J Anaesthesiol","first-page":"6","article-title":"European Society of Anesthesiology and European Board of Anesthesiology guidelines for procedural sedation and analgesia in adults","volume":"35","author":"Hinkelbein J,","year":"2018","unstructured":"Hinkelbein J,\nLamperti M,\nAkeson J, et al. European Society of Anesthesiology and European Board of Anesthesiology guidelines for procedural sedation and analgesia in adults. Eur J Anaesthesiol. 2018;35:6\u201324."},{"key":"i1878-7177-71-4-171-b05","series-title":"Pediatrics","first-page":"293","article-title":"Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients","volume":"122","author":"Keidan I,","year":"2008","unstructured":"Keidan I,\nGravenstein D,\nBerkenstadt H,\nZiv A,\nShavit I,\nSidi A. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008;122:293\u2013298."},{"key":"i1878-7177-71-4-171-b06","series-title":"Pediatr Anesth","first-page":"604","article-title":"The utility of the pretracheal stethoscope in detecting ventilatory abnormalities during propofol sedation in children","volume":"29","author":"Boriosi JP,","year":"2019","unstructured":"Boriosi JP,\nZhao Q,\nPreston A,\nHollman GA,\nVeyckemans F. The utility of the pretracheal stethoscope in detecting ventilatory abnormalities during propofol sedation in children. Pediatr Anesth. 2019;29:604\u2013610."},{"key":"i1878-7177-71-4-171-b07","series-title":"J Oral Maxillofac Surg","first-page":"1400","article-title":"How much noise is an oral and maxillofacial surgeon exposed to","volume":"76","author":"Kulkarni E,","year":"2018","unstructured":"Kulkarni E,\nAbdallah Y,\nHanseman D,\nKrishnan DG. How much noise is an oral and maxillofacial surgeon exposed to? J Oral Maxillofac Surg. 2018;76:1400\u20131403."},{"key":"i1878-7177-71-4-171-b08","series-title":"J Oral Maxillofac Surg","first-page":"70","article-title":"Are wireless electronic stethoscopes useful for respiratory rate monitoring during intravenous sedation","volume":"76","author":"Morimoto K,","year":"2018","unstructured":"Morimoto K,\nTsutsui Y,\nOgura S,\nSunda K. Are wireless electronic stethoscopes useful for respiratory rate monitoring during intravenous sedation? J Oral Maxillofac Surg. 2018;76:70."},{"key":"i1878-7177-71-4-171-b09","series-title":"Br J Anaesth","first-page":"872","article-title":"Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anesthesia","volume":"108","author":"Mimoz O,","year":"2012","unstructured":"Mimoz O,\nBenard T,\nGaucher A,\nFrasca D,\nDebaene B. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anesthesia. Br J Anaesth. 2012;108:872\u2013875."},{"key":"i1878-7177-71-4-171-b10","series-title":"Anesth Analg","first-page":"69","article-title":"The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic method monitoring and capnometry","volume":"117","author":"Ramsay MA,","year":"2013","unstructured":"Ramsay MA,\nUsman M,\nLagow E,\nMendoza M,\nUntalan E,\nDe Vol E. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic method monitoring and capnometry. Anesth Analg. 2013;117:69\u201375."},{"key":"i1878-7177-71-4-171-b11","series-title":"J Dent Anesth Pain Med","first-page":"97","article-title":"The effect of dental scaling noise during intravenous sedation on acoustic respiration rate (RRa\u2122)","volume":"18","author":"Kim JH,","year":"2018","unstructured":"Kim JH,\nChi SI,\nKim HJ,\nSeo KS. The effect of dental scaling noise during intravenous sedation on acoustic respiration rate (RRa\u2122). J Dent Anesth Pain Med. 2018;18:97\u2013103."},{"key":"i1878-7177-71-4-171-b12","series-title":"Medicine (Baltimore)","first-page":"e24738","article-title":"A machine-learning based approach to quantify fine crackles in the diagnosis of interstitial pneumonia: a proof-of-concept study","volume":"19","author":"Horimasu Y,","year":"2021","unstructured":"Horimasu Y,\nOhshimo S,\nYamaguchi K, et al. A machine-learning based approach to quantify fine crackles in the diagnosis of interstitial pneumonia: a proof-of-concept study. Medicine (Baltimore). 2021;19:e24738."},{"key":"i1878-7177-71-4-171-b13","series-title":"PLoS One","first-page":"e0231262","article-title":"The effect of nasal and oral breathing on airway collapsibility in patients with obstructive sleep apnea: computational fluid dynamics analyses","volume":"15","author":"Suzuki M,","year":"2020","unstructured":"Suzuki M,\nTanuma T. The effect of nasal and oral breathing on airway collapsibility in patients with obstructive sleep apnea: computational fluid dynamics analyses. PLoS One. 2020;15:e0231262."},{"key":"i1878-7177-71-4-171-b14","series-title":"Acta Otolaryngol Suppl","first-page":"228","article-title":"Relationship between oral breathing and nasal obstruction in patients with obstructive sleep apnea","volume":"523","author":"Ohki M,","year":"1996","unstructured":"Ohki M,\nUsui N,\nKanazawa H,\nHara I,\nKawano K. Relationship between oral breathing and nasal obstruction in patients with obstructive sleep apnea. Acta Otolaryngol Suppl. 1996;523:228\u2013230."},{"key":"i1878-7177-71-4-171-b15","series-title":"Br J Anaesth","first-page":"316","article-title":"Accuracy of respiratory rate monitoring by capnometry using the Capnomask(R) in extubated patients receiving supplemental oxygen after surgery","volume":"108","author":"Gaucher A,","year":"2012","unstructured":"Gaucher A,\nFrasca D,\nMimoz O,\nDebaene B. Accuracy of respiratory rate monitoring by capnometry using the Capnomask(R) in extubated patients receiving supplemental oxygen after surgery. Br J Anaesth. 2012;108:316\u2013320."},{"key":"i1878-7177-71-4-171-b16","series-title":"Br J Anaesth","first-page":"195","article-title":"Evaluation of acoustic method respiration rate monitoring after extubation in intensive care unit patients","volume":"113","author":"Autet LM,","year":"2014","unstructured":"Autet LM,\nFrasca D,\nPinsard M, et al. Evaluation of acoustic method respiration rate monitoring after extubation in intensive care unit patients. Br J Anaesth. 2014;113:195\u2013197."},{"key":"i1878-7177-71-4-171-b17","series-title":"Sci Rep","first-page":"21196","article-title":"New acoustic monitoring system quantifying aspiration risk during monitored anaesthesia care","volume":"13","author":"Shimizu Y,","year":"2023","unstructured":"Shimizu Y,\nOhshimo S,\nSaeki N, et al. New acoustic monitoring system quantifying aspiration risk during monitored anaesthesia care. Sci Rep. 2023;13:21196."},{"key":"i1878-7177-71-4-171-b18","series-title":"J Med Invest","first-page":"430","article-title":"Usefulness of new acoustic respiratory sound monitoring with artificial intelligence for upper airway assessment in obese patients during monitored anesthesia care","volume":"70","author":"Shimizu Y,","year":"2023","unstructured":"Shimizu Y,\nSaeki N,\nOhshimo S, et al. Usefulness of new acoustic respiratory sound monitoring with artificial intelligence for upper airway assessment in obese patients during monitored anesthesia care. J Med Invest. 2023;70:430\u2013435."},{"key":"i1878-7177-71-4-171-b19","series-title":"J Family Med Prim Care","first-page":"2987","article-title":"Noise intensities encountered in university dental clinics during different specialty treatments","volume":"10","author":"Baseer MA,","year":"2021","unstructured":"Baseer MA,\nAl Saffan A,\nAlMasoud SM, et al. Noise intensities encountered in university dental clinics during different specialty treatments. J Family Med Prim Care. 2021;10:2987\u20132992."}],"container-title":["Anesthesia Progress"],"original-title":[],"link":[{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/71\/4\/article-p171.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/71\/4\/article-p171.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/71\/4\/article-p171.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T00:30:38Z","timestamp":1733272238000},"score":1,"resource":{"primary":{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/71\/4\/article-p171.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":19,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.2344\/23-00017","relation":{},"ISSN":["1878-7177","0003-3006"],"issn-type":[{"value":"1878-7177","type":"electronic"},{"value":"0003-3006","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]}}}