{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,8]],"date-time":"2024-10-08T04:16:20Z","timestamp":1728360980902},"reference-count":17,"publisher":"American Dental Society of Anesthesiology (ADSA)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"abstract":"<jats:p>An estimation of the appropriate tubing depth for fixation is helpful to prevent inadvertent endobronchial intubation and prolapse of cuff from the vocal cord. A feasible estimation formula should be established. We measured the anatomical length of the upper-airway tract through the oral and nasal pathways on cephalometric radiographs and tried to establish the estimation formula from the height of the patient. The oral upper-airway tract was measured from the tip of the incisor to the vocal cord. The nasal upper-airway tract was measured from the tip of the nostril to the vocal cord. The tracts were smoothly traced by using software. The length of the oral upper-airway tract was 13.2 \u00b1 0.8 cm, and the nasal upper-airway tract was 16.1 \u00b1 0.9 cm. We found no gender difference (<jats:italic>p<\/jats:italic> &gt; .05). The correlations between the patients' height and the length of the oral and nasal upper-airway tracts were 0.692 and 0.760, respectively. We found that the formulas (height\/10) \u2212 3 (in cm) for oral upper-airway and (height\/10) + 1 (in cm) for nasal upper-airway tract are the simple fit estimation formulas. The average error and standard deviation of the estimated values from the measured values were 0.50 \u00b1 0.66 cm for the oral tract and 0.39 \u00b1 0.63 cm for the nasal tract. Thus, considering the length of the intubation marker of each product (DM), we would like to propose the length of tube fixation as (height\/10) + 1 + DM for nasal intubation and (height\/10) \u2212 3 + DM for oral intubation. In conclusion, the estimation formulas of (height\/10) \u2212 3 + DM and (height\/10) + 1 + DM for oral and nasal intubation, respectively, are within almost 1 cm error in most cases.<\/jats:p>","DOI":"10.2344\/anpr-65-04-04","type":"journal-article","created":{"date-parts":[[2019,3,18]],"date-time":"2019-03-18T16:51:23Z","timestamp":1552927883000},"page":"8-13","source":"Crossref","is-referenced-by-count":5,"title":["A Formula for Estimating the Appropriate Tube Depth for Intubation"],"prefix":"10.2344","volume":"66","author":[{"given":"Keiko","family":"Yao","sequence":"first","affiliation":[{"name":"Department of Perioperative Medicine, Division of Anesthesiology, Showa University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kinuko","family":"Goto","sequence":"additional","affiliation":[{"name":"Department of Perioperative Medicine, Division of Anesthesiology, Showa University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akiko","family":"Nishimura","sequence":"additional","affiliation":[{"name":"Department of Perioperative Medicine, Division of Anesthesiology, Showa University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Reina","family":"Shimazu","sequence":"additional","affiliation":[{"name":"Department of Perioperative Medicine, Division of Anesthesiology, Showa University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Tachikawa","sequence":"additional","affiliation":[{"name":"Department of Perioperative Medicine, Division of Anesthesiology, Showa University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takehiko","family":"Iijima","sequence":"additional","affiliation":[{"name":"Department of Perioperative Medicine, Division of Anesthesiology, Showa University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1191","reference":[{"key":"i0003-3006-66-1-8-b01","series-title":"Anesthesiology","first-page":"828","article-title":"Adverse respiratory events in anesthesia: a closed claims analysis","volume":"72","author":"Caplan \n              RA,","year":"1990","unstructured":"Caplan \n              RA, \n            \n            \n              Posner \n              KL, \n            \n            \n              Ward \n              RJ, \n            \n            \n              Cheney \n              FW. \n            \n          \n          Adverse respiratory events in anesthesia: a closed claims analysis. Anesthesiology. 1990;72:828\u2013833."},{"key":"i0003-3006-66-1-8-b02","series-title":"Anesth Prog","first-page":"66","article-title":"Inadvertent endobronchial intubation in a patient with a short neck length","volume":"62","author":"Cornelius \n              B,","year":"2015","unstructured":"Cornelius \n              B, \n            \n            \n              Sakai \n              T. \n            \n          \n          Inadvertent endobronchial intubation in a patient with a short neck length. Anesth Prog. 2015;62:66\u201370."},{"key":"i0003-3006-66-1-8-b03","series-title":"Anesthesiology","first-page":"1012","article-title":"Auscultation versus point-of-care ultrasound to determine endotracheal versus bronchial intubation: a diagnostic accuracy study","volume":"124","author":"Ramsingh \n              D,","year":"2016","unstructured":"Ramsingh \n              D, \n            \n            \n              Frank \n              E, \n            \n            \n              Haughton \n              R, \n            \n            et al. \n          Auscultation versus point-of-care ultrasound to determine endotracheal versus bronchial intubation: a diagnostic accuracy study. Anesthesiology. 2016;124:1012\u20131020."},{"key":"i0003-3006-66-1-8-b04","series-title":"BMJ","article-title":"Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial","author":"Sitzwohl \n              C,","year":"2010","unstructured":"Sitzwohl \n              C, \n            \n            \n              Langheinrich \n              A, \n            \n            \n              Schober \n              A, \n            \n            et al. \n          Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial. BMJ. 2010;341:c5943."},{"key":"i0003-3006-66-1-8-b05","series-title":"Ann Emerg Med","first-page":"116","article-title":"Endotracheal tip position in the arrested patient","volume":"11","author":"Dronen \n              S,","year":"1982","unstructured":"Dronen \n              S, \n            \n            \n              Chadwick \n              O, \n            \n            \n              Nowak \n              R. \n            \n          \n          Endotracheal tip position in the arrested patient. Ann Emerg Med. 1982;11:116\u2013117."},{"key":"i0003-3006-66-1-8-b06","series-title":"Anesthesiology","first-page":"461","article-title":"A comparison of pediatric and adult anesthesia closed malpractice claims","volume":"78","author":"Morray \n              JP,","year":"1993","unstructured":"Morray \n              JP, \n            \n            \n              Geiduschek \n              JM, \n            \n            \n              Caplan \n              RA, \n            \n            \n              Posner \n              KL, \n            \n            \n              Gild \n              WM, \n            \n            \n              Cheney \n              FW. \n            \n          \n          A comparison of pediatric and adult anesthesia closed malpractice claims. Anesthesiology. 1993;78:461\u2013467."},{"key":"i0003-3006-66-1-8-b07","series-title":"Anaesthesist","first-page":"115","article-title":"Estimation of the optimal tube length: systematic review article on published formulae for infants and children","volume":"65","author":"Boensch \n              M,","year":"2016","unstructured":"Boensch \n              M, \n            \n            \n              Schick \n              V, \n            \n            \n              Spelten \n              O, \n            \n            \n              Hinkelbein \n              J. \n            \n          \n          Estimation of the optimal tube length: systematic review article on published formulae for infants and children. Anaesthesist. 2016;65:115\u2013121."},{"issue":"12","key":"i0003-3006-66-1-8-b08","series-title":"Paediatr Anaesth","first-page":"1238","article-title":"New formulae for predicting tracheal tube length","volume":"16","author":"Lau \n              N,","year":"2006","unstructured":"Lau \n              N, \n            \n            \n              Playfor \n              SD, \n            \n            \n              Rashid \n              A, \n            \n            \n              Dhanarass \n              M. \n            \n          \n          New formulae for predicting tracheal tube length. Paediatr Anaesth. 2006;16(12):1238\u20131243."},{"key":"i0003-3006-66-1-8-b09","series-title":"Korean J Anesthesiol","first-page":"249","article-title":"Assessment of airway length of Korean adults and children for otolaryngology and ophthalmic surgery using a fiberoptic bronchoscope","volume":"59","author":"Pak \n              HJ,","year":"2010","unstructured":"Pak \n              HJ, \n            \n            \n              Hong \n              BH, \n            \n            \n              Lee \n              WH. \n            \n          \n          Assessment of airway length of Korean adults and children for otolaryngology and ophthalmic surgery using a fiberoptic bronchoscope. Korean J Anesthesiol. 2010;59:249\u2013255."},{"key":"i0003-3006-66-1-8-b10","series-title":"J Med Assoc Thai","first-page":"173","article-title":"Estimation of the proper length of nasotracheal intubation by Chula formula","volume":"91","author":"Techanivate \n              A,","year":"2008","unstructured":"Techanivate \n              A, \n            \n            \n              Kumwilaisak \n              K, \n            \n            \n              Worasawate \n              W, \n            \n            \n              Tanyong \n              A. \n            \n          \n          Estimation of the proper length of nasotracheal intubation by Chula formula. J Med Assoc Thai. 2008;91:173\u2013180."},{"key":"i0003-3006-66-1-8-b11","series-title":"Indian J Anaesth","first-page":"488","article-title":"Appropriate depth of placement of oral endotracheal tube and its possible determinants in Indian adult patients","volume":"55","author":"Varshney \n              M,","year":"2011","unstructured":"Varshney \n              M, \n            \n            \n              Sharma \n              K, \n            \n            \n              Kumar \n              R, \n            \n            \n              Varshney \n              PG. \n            \n          \n          Appropriate depth of placement of oral endotracheal tube and its possible determinants in Indian adult patients. Indian J Anaesth. 2011;55:488\u2013493."},{"key":"i0003-3006-66-1-8-b12","series-title":"Br J Anaesth","first-page":"489","article-title":"The clinical implication of the vocal cords-carina distance in anaesthetized Chinese adults during orotracheal intubation","volume":"97","author":"Chong \n              DY,","year":"2006","unstructured":"Chong \n              DY, \n            \n            \n              Greenland \n              KB, \n            \n            \n              Tan \n              ST, \n            \n            \n              Irwin \n              MG, \n            \n            \n              Hung \n              CT. \n            \n          \n          The clinical implication of the vocal cords-carina distance in anaesthetized Chinese adults during orotracheal intubation. Br J Anaesth. 2006;97:489\u2013495."},{"key":"i0003-3006-66-1-8-b13","series-title":"Anaesth Intensive Care","first-page":"156","article-title":"The relationship between a person's height and appropriate endotracheal tube length","volume":"20","author":"Eagle \n              CC.","year":"1992","unstructured":"Eagle \n              CC. \n            \n          \n          The relationship between a person's height and appropriate endotracheal tube length. Anaesth Intensive Care. 1992;20:156\u2013160."},{"issue":"8476","key":"i0003-3006-66-1-8-b14","series-title":"Lancet","first-page":"307","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland \n              JM,","year":"1986","unstructured":"Bland \n              JM, \n            \n            \n              Altman \n              DG. \n            \n          \n          Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307\u2013310."},{"article-title":"How can I decide the sample size for a study of agreement between two methods of measurement?","author":"Bland \n              M.","key":"i0003-3006-66-1-8-b15","unstructured":"Bland \n              M. \n            \n          \n          How can I decide the sample size for a study of agreement between two methods of measurement?\n          Available at: https:\/\/www-users.york.ac.uk\/\u223cmb55\/meas\/sizemeth.htm. Accessed January 11, 2018."},{"key":"i0003-3006-66-1-8-b16","series-title":"J Med Assoc Thai","first-page":"775","article-title":"Depth of endotracheal tubes in Thai adult patients","volume":"88","author":"Techanivate \n              A,","year":"2005","unstructured":"Techanivate \n              A, \n            \n            \n              Rodanant \n              O, \n            \n            \n              Charoenraj \n              P, \n            \n            \n              Kumwilaisak \n              K. \n            \n          \n          Depth of endotracheal tubes in Thai adult patients. J Med Assoc Thai. 2005;88:775\u2013781."},{"key":"i0003-3006-66-1-8-b17","series-title":"Br J Anaesth","first-page":"269","article-title":"Pathways through the nose for nasal intubation: a comparison of three endotracheal tubes","volume":"100","author":"Ahmed-Nusrath \n              A,","year":"2008","unstructured":"Ahmed-Nusrath \n              A, \n            \n            \n              Tong \n              JL, \n            \n            \n              Smith \n              JE. \n            \n          \n          Pathways through the nose for nasal intubation: a comparison of three endotracheal tubes. Br J Anaesth. 2008;100:269\u2013274."}],"container-title":["Anesthesia Progress"],"original-title":[],"link":[{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/66\/1\/article-p8.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/anesthesia-progress\/article-pdf\/66\/1\/8\/2416649\/anpr-65-04-04.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/66\/1\/article-p8.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/66\/1\/article-p8.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T12:43:52Z","timestamp":1728305032000},"score":1,"resource":{"primary":{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/66\/1\/article-p8.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"references-count":17,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.2344\/anpr-65-04-04","relation":{},"ISSN":["0003-3006","1878-7177"],"issn-type":[{"type":"print","value":"0003-3006"},{"type":"electronic","value":"1878-7177"}],"subject":[],"published":{"date-parts":[[2019]]}}}