{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,8]],"date-time":"2024-10-08T04:15:56Z","timestamp":1728360956816},"reference-count":7,"publisher":"American Dental Society of Anesthesiology (ADSA)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020]]},"abstract":"<jats:p>A patient undergoing a bilateral sagittal split and LeFort 1 maxillary osteotomy performed under general anesthesia required emergent intraoperative exchange of a potentially damaged nasotracheal tube. This exchange was smoothly performed under constant indirect visualization using the McGrath MAC video laryngoscopy system. After the exchange, ventilation of the patient dramatically improved. The removed endotracheal tube was torn 19 cm from the distal tip. The McGrath MAC was useful for visualizing the glottis and confirming the entire course of the tube exchange despite the patient's having a difficult airway (Cormack-Lehane grade 3).<\/jats:p>","DOI":"10.2344\/anpr-67-02-01","type":"journal-article","created":{"date-parts":[[2020,9,29]],"date-time":"2020-09-29T20:48:33Z","timestamp":1601412513000},"page":"174-176","source":"Crossref","is-referenced-by-count":2,"title":["A Case of Successful Tracheal Tube Exchange With McGrath MAC for Tube Damage During Oral Surgery"],"prefix":"10.2344","volume":"67","author":[{"given":"Yuko","family":"Koyanagi","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Nihon University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eiko","family":"Yokota","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Nihon University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marina","family":"Iwata","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Nihon University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ritsuko","family":"Shimazaki","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Nihon University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toru","family":"Misaki","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Nihon University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiyuki","family":"Oi","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Nihon University School of Dentistry, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1191","reference":[{"key":"i0003-3006-67-3-174-b01","series-title":"Masui","first-page":"1315","article-title":"A case of successful tracheal tube exchange with Airway Scope\u00ae for tube damage during maxillo-mandibular osteotomy [in Japanese]","volume":"59","author":"Nakai","year":"2010","unstructured":"Nakai\n              K,\n            \n            \n              Kitayama\n              M,\n            \n            \n              Niwa\n              H,\n            \n            \n              Hashiba\n              E,\n            \n            \n              Wada\n              M,\n            \n            \n              Hirota\n              K.\n            \n          \n          A case of successful tracheal tube exchange with Airway Scope\u00ae for tube damage during maxillo-mandibular osteotomy [in Japanese].\n\t\t\t\t\tMasui.\n\t\t\t\t\t2010;59:1315\u20131317."},{"key":"i0003-3006-67-3-174-b02","series-title":"J Jpn Dent Soc Anesthesiol","first-page":"39","article-title":"A report of a damaged endotracheal tube during oral surgery [in Japanese]","volume":"31","author":"Kita","year":"2003","unstructured":"Kita\n              F,\n            \n            \n              Miyawaki\n              T,\n            \n            \n              Kohjitani\n              A,\n            \n            et al.\n\t\t\t\t\t\n          A report of a damaged endotracheal tube during oral surgery [in Japanese].\n\t\t\t\t\tJ Jpn Dent Soc Anesthesiol.\n\t\t\t\t\t2003;31:39\u201340."},{"key":"i0003-3006-67-3-174-b03","series-title":"Anesth Prog","first-page":"247","article-title":"Intraoperative management of a partially severed endotracheal tube during orthognathic surgery","volume":"33","author":"Peskin","year":"1986","unstructured":"Peskin\n              RM,\n            \n            \n              Sachs\n              SA.\n            \n          \n          Intraoperative management of a partially severed endotracheal tube during orthognathic surgery.\n\t\t\t\t\tAnesth Prog.\n\t\t\t\t\t1986;33:247\u2013251."},{"key":"i0003-3006-67-3-174-b04","series-title":"Anesthesiology","first-page":"891","article-title":"Original method for in situ repair of damage to endotracheal tube","volume":"93","author":"Briskin","year":"2000","unstructured":"Briskin\n              A,\n            \n            \n              Drenger\n              B,\n            \n            \n              Regev\n              E,\n            \n            \n              Zeltser\n              R,\n            \n            \n              Kadari\n              A,\n            \n            \n              Gozal\n              Y.\n            \n          \n          Original method for in situ repair of damage to endotracheal tube.\n\t\t\t\t\tAnesthesiology.\n\t\t\t\t\t2000;93:891\u2013892."},{"key":"i0003-3006-67-3-174-b05","series-title":"J Jpn Soc Clin Anesth","first-page":"457","article-title":"A case of endotracheal tube damage during maxillo-mandibular osteotomy [in Japanese]","volume":"28","author":"Takagi","year":"2008","unstructured":"Takagi\n              Y,\n            \n            \n              Kurita\n              T,\n            \n            \n              Sato\n              S.\n            \n          \n          A case of endotracheal tube damage during maxillo-mandibular osteotomy [in Japanese].\n\t\t\t\t\tJ Jpn Soc Clin Anesth.\n\t\t\t\t\t2008;28:457\u2013460."},{"key":"i0003-3006-67-3-174-b06","series-title":"Masui","first-page":"990","article-title":"Use of the Pentax-AWS videolaryngoscope and an exchange catheter for tube exchange [in Japanese]","volume":"57","author":"Asai","year":"2008","unstructured":"Asai\n              T,\n            \n            \n              Shingu\n              K.\n            \n          \n          Use of the Pentax-AWS videolaryngoscope and an exchange catheter for tube exchange [in Japanese].\n\t\t\t\t\tMasui.\n\t\t\t\t\t2008;57:990\u2013992."},{"key":"i0003-3006-67-3-174-b07","series-title":"Anesth Analg","first-page":"1357","article-title":"Continuous airway access for the difficult extubation: the efficacy of the airway exchange catheter","volume":"105","author":"Mort","year":"2007","unstructured":"Mort\n              TC.\n            \n          \n          Continuous airway access for the difficult extubation: the efficacy of the airway exchange catheter.\n\t\t\t\t\tAnesth Analg.\n\t\t\t\t\t2007;105:1357\u20131362."}],"container-title":["Anesthesia Progress"],"original-title":[],"link":[{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/67\/3\/article-p174.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/anesthesia-progress\/article-pdf\/67\/3\/174\/2598072\/i0003-3006-67-3-174.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/67\/3\/article-p174.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/downloadpdf\/journals\/anpr\/67\/3\/article-p174.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T12:43:30Z","timestamp":1728305010000},"score":1,"resource":{"primary":{"URL":"https:\/\/anesthesiaprogress.kglmeridian.com\/view\/journals\/anpr\/67\/3\/article-p174.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":7,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.2344\/anpr-67-02-01","relation":{},"ISSN":["1878-7177","0003-3006"],"issn-type":[{"type":"electronic","value":"1878-7177"},{"type":"print","value":"0003-3006"}],"subject":[],"published":{"date-parts":[[2020]]}}}