{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T20:09:33Z","timestamp":1788898173413,"version":"build-2803163510"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Cardiac implantable electronic device (CIED) infections are associated with substantial morbidity and mortality, and early recognition with referral for device extraction is crucial for optimal outcomes. General practitioners (GPs) are essential for long-term follow-up, yet their adherence to international guidelines remains poorly defined. This survey aimed to assess GPs\u2019 levels of awareness and clinical management of CIED infections.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A nationwide survey endorsed by the Electrophysiology and Cardiac Pacing Study Group of the Italian Federation of Cardiology was sent to GPs throughout Italy. The questionnaire explored epidemiology, prognosis, clinical scenarios, preventive strategies, therapeutic pathways, and educational background regarding CIED infections.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 183 GPs from 10 Italian regions participated. Most respondents (62.8%) correctly estimated CIED infection incidence at 1\u20132%. However, two-thirds (122 GPs, 66.6%) considered conservative management to be associated with good outcomes, and only 28.4% recognized CIED infection as a condition with a poor prognosis. While 93.4% identified systemic inflammatory symptoms as warning signs, fewer than one-third would refer febrile CIED carriers to an electrophysiology specialist. Preventive strategies were heterogeneous, with more than half (54.1%) prescribing antibiotic prophylaxis before dental procedures. Only six GPs (3.8%) reported having received adequate training or dedicated education courses on CIED infections during their educational pathway.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Italian GPs demonstrate reasonable epidemiological awareness of CIED infections. However, major gaps exist in prognostic understanding, diagnostic referral, prevention, and therapeutic alignment with guidelines. These findings highlight the need for structured educational programs and shared care pathways between primary care and electrophysiology services.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2459\/jcm.0000000000001925","type":"journal-article","created":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T20:00:48Z","timestamp":1788897648000},"page":"634-640","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Cardiac implantable electronic device infection awareness and management: nationwide survey amongst general practitioners"],"prefix":"10.2459","volume":"27","author":[{"given":"Daniele","family":"Faccenda","sequence":"first","affiliation":[{"name":"Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy"},{"name":"Division of Cardiology, Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Lugano, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Santoro","sequence":"additional","affiliation":[{"name":"Department of Medical and Surgical Sciences, University of Foggia, Foggia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicol\u00f2","family":"Sisti","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Hospital of Gubbio-Gualdo Tadino, Regional Healthcare Unit, Gubbio"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfonsomaria","family":"Salucci","sequence":"additional","affiliation":[{"name":"Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Migliore","sequence":"additional","affiliation":[{"name":"Department of Cardiac, Thoracic, and Vascular Sciences and Public Health University of Padova, Padova,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Strangio","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Magna Graecia University of Catanzaro, Catanzaro"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Frontera","sequence":"additional","affiliation":[{"name":"Electrophysiology Unit, De Gasperis Cardio Center, Niguarda Hospital, Milan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucy","family":"Barone","sequence":"additional","affiliation":[{"name":"Department of Systems Medicine, Policlinico Tor Vergata: Fondazione PTV, Rome"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matteo","family":"Anselmino","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Cardiovascular and Thoracic Department, Citt\u00e0 della Salute e della Scienza di Torino Hospital, Turin \u2013 Department of Medical Sciences, University of Turin, Turin"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianfranco","family":"Mitacchione","sequence":"additional","affiliation":[{"name":"Department of Electrophysiology and Cardiac Pacing, ASST Spedali Civili, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enrico","family":"Baldi","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Cardiac Arrest and Resuscitation Research Team (RESTART), Fondazione IRCCS Policlinico San Matteo, Pavia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valerio","family":"Pergola","sequence":"additional","affiliation":[{"name":"Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Curcio","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, Rende"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teresa","family":"Strisciuglio","sequence":"additional","affiliation":[{"name":"Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Ammirati","sequence":"additional","affiliation":[{"name":"Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Mugnai","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Cardio-Thoracic Department, University Hospital of Verona, Verona"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria C.","family":"Gatto","sequence":"additional","affiliation":[{"name":"Unit of Cardiology, Emergency Department, Sant\u2019Eugenio Hospital, Rome"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Rapacciuolo","sequence":"additional","affiliation":[{"name":"Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy"},{"name":"Betania Evangelic Hospital, Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,31]]},"reference":[{"key":"R1-20260908","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1093\/eurheartj\/ehz316","article-title":"Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982\u20132018)","volume":"40","author":"Olsen","year":"2019","journal-title":"Eur Heart J"},{"key":"R2-20260908","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1093\/europace\/euz246","article-title":"European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections \u2013 endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association","volume":"22","author":"Blomstr\u00f6m-Lundqvist","year":"2020","journal-title":"EP Europace"},{"key":"R3-20260908","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1056\/NEJMoa1901111","article-title":"Antibacterial envelope to prevent cardiac implantable device infection","volume":"380","author":"Tarakji","year":"2019","journal-title":"N Engl J Med"},{"key":"R4-20260908","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"R5-20260908","first-page":"225","article-title":"Redo procedures and chronic renal dysfunction are associated with higher risk of cardiac electronic device infections","volume":"66","author":"Morani","year":"2018","journal-title":"Minerva Cardioangiol"},{"key":"R6-20260908","doi-asserted-by":"crossref","first-page":"3948","DOI":"10.1093\/eurheartj\/ehad193","article-title":"2023 ESC Guidelines for the management of endocarditis: developed by the task force on the management of endocarditis of the European Society of Cardiology (ESC) Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS) and the European Association","volume":"44","author":"Delgado","year":"2023","journal-title":"Eur Heart J"},{"key":"R7-20260908","doi-asserted-by":"crossref","first-page":"E201","DOI":"10.1161\/CIR.0000000000001187","article-title":"Update on cardiovascular implantable electronic device infections and their prevention, diagnosis, and management: a scientific statement from the American Heart Association","volume":"149","author":"Baddour","year":"2024","journal-title":"Circulation"},{"key":"R8-20260908","first-page":"328","article-title":"La gestione delle infezioni nei pazienti portatori di dispositivi impiantabili","volume":"23","author":"Nesti","year":"2022","journal-title":"G Ital Cardiol"},{"issue":"(Suppl 2)","key":"R9-20260908","doi-asserted-by":"crossref","first-page":"ii1","DOI":"10.1093\/europace\/eux258","article-title":"A decade of information on the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology Countries: 2017 report from the European Heart Rhythm Association","volume":"19","author":"Raatikainen","year":"2017","journal-title":"EP Europace"},{"key":"R10-20260908","doi-asserted-by":"crossref","first-page":"2726","DOI":"10.1016\/j.hrthm.2024.11.024","article-title":"Bloodstream infection in patients with cardiac implantable electronic devices and prosthetic heart valves: the role of PET-CT","volume":"22","author":"\u00d6zkartal","year":"2025","journal-title":"Heart Rhythm"},{"key":"R11-20260908","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1001\/jamacardio.2023.0467","article-title":"Association of the timing and extent of cardiac implantable electronic device infections with mortality","volume":"8","author":"Han","year":"2023","journal-title":"JAMA Cardiol"},{"key":"R12-20260908","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1093\/europace\/euaa367","article-title":"EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and \u2026","volume":"23","author":"Burri","year":"2021","journal-title":"EP Europace"},{"key":"R13-20260908","doi-asserted-by":"crossref","first-page":"3098","DOI":"10.1016\/j.jacc.2018.09.068","article-title":"Prevention of arrhythmia device infection trial: the PADIT Trial","volume":"72","author":"Krahn","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"R14-20260908","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1016\/j.jacc.2016.01.009","article-title":"Clinically significant pocket hematoma increases long-term risk of device infection: BRUISE CONTROL INFECTION Study","volume":"67","author":"Essebag","year":"2016","journal-title":"J Am Coll Cardiol"},{"key":"R15-20260908","doi-asserted-by":"crossref","first-page":"2195","DOI":"10.1111\/jce.15625","article-title":"Lead-related infective endocarditis with vegetations: prevalence and impact of pulmonary embolism in patients undergoing transvenous lead extraction","volume":"33","author":"Bontempi","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R16-20260908","doi-asserted-by":"crossref","first-page":"105","DOI":"10.2459\/JCM.0000000000001410","article-title":"Incidence and mortality of infective endocarditis in the last decade: a single center study","volume":"24","author":"Lisi","year":"2023","journal-title":"J Cardiovasc Med"},{"key":"R17-20260908","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1001\/jamacardio.2023.3379","article-title":"Lead extraction and mortality among patients with cardiac implanted electronic device infection","volume":"8","author":"Pokorney","year":"2023","journal-title":"JAMA Cardiol"},{"key":"R18-20260908","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1093\/europace\/euaa218","article-title":"Knowledge gaps, lack of confidence, and system barriers to guideline implementation among European physicians managing patients with CIED lead or infection complications: a European Heart Rhythm Association\/European Society of Cardiology educational need\u2026","volume":"22","author":"Rao","year":"2020","journal-title":"Europace"}],"container-title":["Journal of Cardiovascular Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.2459\/JCM.0000000000001925","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T20:00:50Z","timestamp":1788897650000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.2459\/JCM.0000000000001925"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,31]]},"references-count":18,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.2459\/jcm.0000000000001925","relation":{},"ISSN":["1558-2027","1558-2035"],"issn-type":[{"value":"1558-2027","type":"print"},{"value":"1558-2035","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,31]]},"assertion":[{"value":"2026-05-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}