{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T05:21:09Z","timestamp":1769923269294,"version":"3.49.0"},"reference-count":26,"publisher":"American Veterinary Medical Association (AVMA)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["ajvr"],"published-print":{"date-parts":[[2022,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:sec>\n<jats:title>OBJECTIVE<\/jats:title>\n<jats:p>To perform qualitative and quantitative analysis of positron emission tomography (PET)\/CT images using spontaneous ventilation (SV) and positive-pressure breath-hold (PPBH) techniques in order to demonstrate the feasibility of PPBH PET\/CT to decrease respiration-induced artifacts.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>ANIMALS<\/jats:title>\n<jats:p>5 healthy female mixed-breed dogs.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>PROCEDURES<\/jats:title>\n<jats:p>2-([18F]fluoro)-2-deoxy-D-glucose (was administered to each anesthetized dog. An SV PET\/CT scan was performed from the head to the femur using 8 bed positions (3 min\/bed) followed by a PPBH scan centered over the diaphragm with a single bed position (1.5 min\/bed). PET image quality, the misalignment of organs between PET and CT images, and standardized uptake values (SUVs) of liver adjacent to diaphragm were compared between SV and PPBH.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>RESULTS<\/jats:title>\n<jats:p>Overall image quality and conspicuity of anatomic structures were superior in PPBH than in SV PET images. PPBH induced significantly less misalignment of the liver and diaphragm in all planes compared to SV. For the gall bladder, PPBH showed significantly less misalignment than SV only in the transverse plane. The maximum SUV in all of the liver areas was significantly higher with PPBH compared to SV. PPBH exhibited significantly higher mean SUV in the liver adjacent to the left diaphragmatic dome and left lateral border and higher minimum SUV only in the liver adjacent to the left diaphragmatic dome.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>CLINICAL RELEVANCE<\/jats:title>\n<jats:p>PPBH was demonstrated to be a feasible PET\/CT protocol with higher PET image quality, less organ misalignment on fused PET\/CT, and more accurate SUVs of the liver compared to SV PET\/CT in healthy dogs.<\/jats:p>\n<\/jats:sec>","DOI":"10.2460\/ajvr.21.08.0102","type":"journal-article","created":{"date-parts":[[2022,5,8]],"date-time":"2022-05-08T15:44:06Z","timestamp":1652024646000},"page":"405-411","source":"Crossref","is-referenced-by-count":2,"title":["Positive-pressure breath-hold positron emission tomography\/computed tomography is feasible for respiratory-induced artifact reduction in healthy dogs"],"prefix":"10.2460","volume":"83","author":[{"given":"Sangkyung","family":"Choen","sequence":"first","affiliation":[{"name":"Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ehren M.","family":"McLarty","sequence":"additional","affiliation":[{"name":"Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Pascoe","sequence":"additional","affiliation":[{"name":"Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allison L.","family":"Zwingenberger","sequence":"additional","affiliation":[{"name":"Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1272","reference":[{"issue":"2","key":"ref1","series-title":"PLoS One","first-page":"e0172651","article-title":"Evaluation of 18-F-fluoro-2-deoxyglucose (FDG) positron emission tomography\/computed tomography (PET\/CT) as a staging and monitoring tool for dogs with stage-2 splenic hemangiosarcoma\u2014a pilot study","volume":"12","author":"Borgatti A","year":"2017","unstructured":"Borgatti A, Winter AL, Stuebner K,  Evaluation of 18-F-fluoro-2-deoxyglucose (FDG) positron emission tomography\/computed tomography (PET\/CT) as a staging and monitoring tool for dogs with stage-2 splenic hemangiosarcoma\u2014a pilot study. PLoS One. 2017;12(2):e0172651. doi:10.1371\/journal.pone.0172651"},{"issue":"2","key":"ref2","series-title":"Nucl Med Commun","first-page":"113","article-title":"Management of respiratory motion in PET\/computed tomography: the state of the art","volume":"35","author":"P\u00e9pin A","year":"2014","unstructured":"P\u00e9pin A, Daouk J, Bailly P, Hapdey S, Meyer ME. Management of respiratory motion in PET\/computed tomography: the state of the art. Nucl Med Commun. 2014;35(2):113\u2013122."},{"issue":"4","key":"ref3","series-title":"J Nucl Med Technol","first-page":"269","article-title":"Comparison of a free-breathing CT and an expiratory breath-hold CT with regard to spatial alignment of amplitude-based respiratory-gated PET and CT images","volume":"42","author":"van der Vos CS","year":"2014","unstructured":"van der Vos CS, Grootjans W, Meeuwis APW,  Comparison of a free-breathing CT and an expiratory breath-hold CT with regard to spatial alignment of amplitude-based respiratory-gated PET and CT images. J Nucl Med Technol. 2014;42(4):269\u2013273."},{"issue":"3","key":"ref4","series-title":"J Nucl Med Technol","first-page":"156","article-title":"PET\/CT imaging artifacts","volume":"33","author":"Sureshbabu W","year":"2005","unstructured":"Sureshbabu W, Mawlawi O. PET\/CT imaging artifacts. J Nucl Med Technol 2005;33(3):156\u2013162."},{"issue":"1","key":"ref5","series-title":"Quant Imaging Med Surg","first-page":"46","article-title":"Techniques for respiration-induced artifacts reductions in thoracic PET\/CT","volume":"2","author":"Sun T","year":"2012","unstructured":"Sun T, Mok GSP. Techniques for respiration-induced artifacts reductions in thoracic PET\/CT. Quant Imaging Med Surg. 2012;2(1):46\u201352."},{"issue":"5","key":"ref6","series-title":"Nucl Med Commun","first-page":"326","article-title":"Usefulness of a deep-inspiration breath-hold 18F-FDG PET\/CT technique in diagnosing liver, bile duct, and pancreas tumors","volume":"30","author":"Nagamachi S","year":"2009","unstructured":"Nagamachi S, Wakamatsu H, Kiyohara S,  Usefulness of a deep-inspiration breath-hold 18F-FDG PET\/CT technique in diagnosing liver, bile duct, and pancreas tumors. Nucl Med Commun. 2009;30(5):326\u2013332."},{"issue":"2","key":"ref7","series-title":"Medicine (Baltimore)","first-page":"e5882","article-title":"Breath-hold and free-breathing F-18-FDG-PET\/CT in malignant melanoma\u2014detection of additional tumoral foci and effects on quantitative parameters","volume":"96","author":"B\u00e4rwolf R","year":"2017","unstructured":"B\u00e4rwolf R, Zirnsak M, Freesmeyer M. Breath-hold and free-breathing F-18-FDG-PET\/CT in malignant melanoma\u2014detection of additional tumoral foci and effects on quantitative parameters. Medicine (Baltimore). 2017;96(2):e5882. doi:10.1097\/MD.0000000000005882"},{"issue":"24","key":"ref8","series-title":"Phys Med Biol","first-page":"7345","article-title":"The impact of respiratory motion on tumor quantification and delineation in static PET\/CT imaging","volume":"54","author":"Liu C","year":"2009","unstructured":"Liu C, Pierce LA II, Alessio AM, Kinahan PE. The impact of respiratory motion on tumor quantification and delineation in static PET\/CT imaging. Phys Med Biol. 2009;54(24):7345\u20137362."},{"issue":"9","key":"ref9","series-title":"J Vasc Interv Radiol","first-page":"1287","article-title":"Minimizing image misregistration during PET\/CT-guided percutaneous interventions with monitored breath-hold PET and CT acquisitions","volume":"22","author":"Shyn PB","year":"2011","unstructured":"Shyn PB, Tatli S, Sainani NI,  Minimizing image misregistration during PET\/CT-guided percutaneous interventions with monitored breath-hold PET and CT acquisitions. J Vasc Interv Radiol. 2011;22(9):1287\u20131292."},{"issue":"5","key":"ref10","series-title":"AJR J Roentgenol","first-page":"1357","article-title":"Optimal CT breathing protocol for combined thoracic PET\/CT","volume":"187","author":"Gilman MD","year":"2006","unstructured":"Gilman MD, Fischman AJ, Krishnasetty V, Halpern EF, Aquino SL. Optimal CT breathing protocol for combined thoracic PET\/CT. AJR J Roentgenol. 2006;187(5):1357\u20131360."},{"issue":"6","key":"ref11","series-title":"Eur Radiol","first-page":"1118","article-title":"Clinical evaluation of a breathing protocol for PET\/CT","volume":"14","author":"de Juan R","year":"2004","unstructured":"de Juan R, Seifert B, Berthold T, von Schulthess GK, Goerres GW. Clinical evaluation of a breathing protocol for PET\/CT. Eur Radiol. 2004;14(6):1118\u20131123."},{"issue":"2","key":"ref12","series-title":"Vet Radiol Ultrasound","first-page":"117","article-title":"Dual-phase CT angiography of the normal canine portal and hepatic vasculature","volume":"45","author":"Zwingenberger AL","year":"2004","unstructured":"Zwingenberger AL, Schwarz T. Dual-phase CT angiography of the normal canine portal and hepatic vasculature. Vet Radiol Ultrasound. 2004;45(2):117\u2013124."},{"issue":"2","key":"ref13","series-title":"Vet Radiol Ultrasound","first-page":"213","article-title":"Physiologic variants, benign processes, and artifacts from 106 canine and feline FDG-PET\/computed tomography scans","volume":"55","author":"Randall E","year":"2014","unstructured":"Randall E, Loeber S, Kraft S. Physiologic variants, benign processes, and artifacts from 106 canine and feline FDG-PET\/computed tomography scans. Vet Radiol Ultrasound. 2014;55(2):213\u2013226."},{"issue":"1","key":"ref14","series-title":"Vet Radiol Ultrasound","first-page":"102","article-title":"Evaluation of diaphragmatic motion in normal and diaphragmatic paralyzed dogs using M-mode ultrasonography","volume":"55","author":"Choi M","year":"2014","unstructured":"Choi M, Lee N, Kim A,  Evaluation of diaphragmatic motion in normal and diaphragmatic paralyzed dogs using M-mode ultrasonography. Vet Radiol Ultrasound. 2014;55(1):102\u2013108."},{"issue":"2","key":"ref15","series-title":"Vet Radiol Ultrasound","first-page":"133","article-title":"Assessment of respiration-induced displacement of canine abdominal organs in dorsal and ventral recumbency using multislice computed tomography","volume":"56","author":"Oliveira CR","year":"2015","unstructured":"Oliveira CR, Henzler MA, Johnson RA, Drees R. Assessment of respiration-induced displacement of canine abdominal organs in dorsal and ventral recumbency using multislice computed tomography. Vet Radiol Ultrasound. 2015;56(2):133\u2013143."},{"issue":"6","key":"ref16","series-title":"Can Vet J","first-page":"642","article-title":"Hypoglycemia in dogs: causes, management, and diagnosis","volume":"59","author":"Idowu O","year":"2018","unstructured":"Idowu O, Heading K. Hypoglycemia in dogs: causes, management, and diagnosis. Can Vet J. 2018;59(6):642\u2013649."},{"issue":"3","key":"ref17","series-title":"Ann Nucl Med","first-page":"171","article-title":"The reproducibility of deep-inspiration breath-hold 18F-FDG PET\/CT technique in diagnosing various cancers affected by respiratory motion","volume":"24","author":"Nagamachi S","year":"2010","unstructured":"Nagamachi S, Wakamatsu H, Kiyohara S,  The reproducibility of deep-inspiration breath-hold 18F-FDG PET\/CT technique in diagnosing various cancers affected by respiratory motion. Ann Nucl Med. 2010;24(3):171\u2013178."},{"issue":"5","key":"ref18","series-title":"J Nucl Med","first-page":"712","article-title":"Deep-inspiration breath-hold PET\/CT: clinical findings with a new technique for detection and characterization of thoracic lesions","volume":"48","author":"Meirelles GSP","year":"2007","unstructured":"Meirelles GSP, Erdi YE, Nehmeh SA,  Deep-inspiration breath-hold PET\/CT: clinical findings with a new technique for detection and characterization of thoracic lesions. J Nucl Med. 2007;48(5):712\u2013719."},{"issue":"11","key":"ref19","series-title":"Eur J Nucl Med Mol Imaging","first-page":"2507","article-title":"The image quality, lesion detectability, and acquisition time of 18F-FDG total-body PET\/CT in oncological patients","volume":"47","author":"Zhang Y-Q","year":"2020","unstructured":"Zhang Y-Q, Hu P-C, Wu R-Z,  The image quality, lesion detectability, and acquisition time of 18F-FDG total-body PET\/CT in oncological patients. Eur J Nucl Med Mol Imaging. 2020;47(11):2507\u20132515."},{"issue":"4","key":"ref20","series-title":"J Nucl Med Technol","first-page":"255","article-title":"The impact of acquisition time on image quality in whole-body 18F-FDG PET\/CT for cancer staging","volume":"40","author":"Hausmann D","year":"2012","unstructured":"Hausmann D, Dinter DJ, Sadick M, Brade J, Schoenberg SO, B\u00fcsing K. The impact of acquisition time on image quality in whole-body 18F-FDG PET\/CT for cancer staging. J Nucl Med Technol. 2012;40(4):255\u2013258."},{"issue":"1","key":"ref21","series-title":"Ann Nucl Med","first-page":"1","article-title":"Feasibility of deep-inspiration breath-hold PET\/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET\/CT","volume":"28","author":"Yamashita S","year":"2014","unstructured":"Yamashita S, Yokoyama K, Onoguchi M,  Feasibility of deep-inspiration breath-hold PET\/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET\/CT. Ann Nucl Med. 2014;28(1):1\u201310. doi:10.1007\/s12149-013-0774-9"},{"issue":"9","key":"ref22","series-title":"Am J Vet Res","first-page":"1043","article-title":"Fluoroscopic evaluation of diaphragmatic excursion during spontaneous breathing in healthy Beagles","volume":"78","author":"Moon S","year":"2017","unstructured":"Moon S, Park S, Lee SK, Cheon B, Choi J. Fluoroscopic evaluation of diaphragmatic excursion during spontaneous breathing in healthy Beagles. Am J Vet Res. 2017;78(9):1043\u20131048."},{"issue":"6","key":"ref23","series-title":"J Nucl Med","first-page":"910","article-title":"Evaluation of image registration in PET\/CT of the liver and recommendations for optimized imaging","volume":"48","author":"Vogel WV","year":"2007","unstructured":"Vogel WV, van Dalen JA, Wiering B,  Evaluation of image registration in PET\/CT of the liver and recommendations for optimized imaging. J Nucl Med. 2007;48(6):910\u2013919."},{"issue":"2","key":"ref24","series-title":"Vet Radiol Ultrasound","first-page":"182","article-title":"Thoracic and abdominal organ uptake of 2-deoxy-2-[18F]fluoro-d-glucose (18FDG) with positron emission tomography in the normal dog","volume":"49","author":"LeBanc AK","year":"2008","unstructured":"LeBanc AK, Jakoby B, Townsend DW, Daniel GB. Thoracic and abdominal organ uptake of 2-deoxy-2-[18F]fluoro-d-glucose (18FDG) with positron emission tomography in the normal dog. Vet Radiol Ultrasound. 2008;49(2):182\u2013188."},{"issue":"5","key":"ref25","series-title":"Vet Radiol Ultrasound","first-page":"475","article-title":"Which airway pressure should be applied during breath-hold in dogs undergoing thoracic computed tomography","volume":"57","author":"Guarracino A","year":"2016","unstructured":"Guarracino A, Lacitignola L, Auriemma E,  Which airway pressure should be applied during breath-hold in dogs undergoing thoracic computed tomography? Vet Radiol Ultrasound. 2016;57(5):475\u2013481."},{"issue":"8","key":"ref26","series-title":"Am J Vet Res","first-page":"756","article-title":"Effects of airway pressure on contrast enhancement and diameter of the pulmonary artery in healthy dogs as determined by use of computed tomography angiography","volume":"80","author":"Choen S","year":"2019","unstructured":"Choen S, Kim K, Kang K,  Effects of airway pressure on contrast enhancement and diameter of the pulmonary artery in healthy dogs as determined by use of computed tomography angiography. Am J Vet Res. 2019;80(8):756\u2013763."}],"container-title":["American Journal of Veterinary Research"],"original-title":[],"link":[{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/83\/5\/ajvr.21.08.0102.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/83\/5\/ajvr.21.08.0102.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/83\/5\/ajvr.21.08.0102.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T04:37:32Z","timestamp":1749616652000},"score":1,"resource":{"primary":{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/83\/5\/ajvr.21.08.0102.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,1]]},"references-count":26,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.2460\/ajvr.21.08.0102","relation":{},"ISSN":["0002-9645"],"issn-type":[{"value":"0002-9645","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5,1]]}}}