{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T08:10:58Z","timestamp":1747210258328,"version":"3.40.5"},"reference-count":38,"publisher":"American Veterinary Medical Association (AVMA)","issue":"9","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["ajvr"],"published-print":{"date-parts":[[2024,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:sec id=\"sc_a1\">\n<jats:title>OBJECTIVE<\/jats:title>\n<jats:p>To develop an innovative process for stereotactic brain biopsies in dogs and cats that would provide a definitive diagnosis and optimize the management of patients with brain lesions.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sc_a2\">\n<jats:title>ANIMALS<\/jats:title>\n<jats:p>4 dogs and 1 cat diagnosed with 1 or more brain lesion(s) underwent brain biopsies between March 24, 2023, and October 25, 2023.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sc_a3\">\n<jats:title>METHODS<\/jats:title>\n<jats:p>Based on trajectories selected on images of MRI and CT scan performed on each patient, a computerized software program was used to design a 3-D\u2013printed patient-specific device with maxillary dental impression located on a baseplate to secure the patient's head and with insertion ports for the biopsy instrumentations located on a C-arm. As proof of concept, the device was successfully used in 2 cadavers before being used on clinical patients. All biopsy samples were submitted for histopathological examination.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sc_a4\">\n<jats:title>RESULTS<\/jats:title>\n<jats:p>Histological diagnosis was obtained in 80% (4\/5) of the cases (choroid plexus tumor, astrocytoma, meningioma, and chronic meningoencephalitis of unknown origin). In 1 patient, the results of biopsy were nondiagnostic; postmortem diagnosis was consistent with a low-grade oligodendroglioma. All the patients were discharged within 24 hours after the procedure without complications. This novel stereotactic system allows the surgeon to perform safe, easy-to-use, inexpensive, and minimally invasive precise brain biopsies in dogs and cats, without complications.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"sc_a5\">\n<jats:title>CLINICAL RELEVANCE<\/jats:title>\n<jats:p>This unique technique could be applied to any size and type of skull and for any type of brain lesions and would provide diagnostic information that would be valuable for future treatment planning and prognosis.<\/jats:p>\n<\/jats:sec>","DOI":"10.2460\/ajvr.24.04.0122","type":"journal-article","created":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T16:43:27Z","timestamp":1719938607000},"source":"Crossref","is-referenced-by-count":0,"title":["Using a three-dimensional\u2013printed device with the patient's maxillary dental impression allows to perform minimally invasive brain biopsies in dogs and cats: a preliminary study"],"prefix":"10.2460","volume":"85","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2396-1301","authenticated-orcid":true,"given":"Sabrina","family":"Fert","sequence":"first","affiliation":[{"name":"Neurology Department, Centre Hospitalier V\u00e9t\u00e9rinaire Fr\u00e9gis IVC Evidensia, Gentilly, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hadrien","family":"Frankar","sequence":"additional","affiliation":[{"name":"Neurology Department, Centre Hospitalier V\u00e9t\u00e9rinaire Fr\u00e9gis IVC Evidensia, Gentilly, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alice","family":"Dussaux","sequence":"additional","affiliation":[{"name":"Neurology Department, Centre Hospitalier V\u00e9t\u00e9rinaire Fr\u00e9gis IVC Evidensia, Gentilly, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cl\u00e9mence","family":"Berthom\u00e9","sequence":"additional","affiliation":[{"name":"Neurology Department, Centre Hospitalier V\u00e9t\u00e9rinaire Fr\u00e9gis IVC Evidensia, Gentilly, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steeve","family":"Chantrel","sequence":"additional","affiliation":[{"name":"INFINEIS, 3D-Printed Medical Equipment Manufacturing Company, Nice, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laurent","family":"Cauzinille","sequence":"additional","affiliation":[{"name":"Neurology Department, Centre Hospitalier V\u00e9t\u00e9rinaire Fr\u00e9gis IVC Evidensia, Gentilly, France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1272","reference":[{"issue":"1","key":"B1","series-title":"Vet Radiol Ultrasound","first-page":"33","article-title":"Comparative magnetic resonance imaging findings between gliomas and presumed cerebrovascular accidents in dogs","volume":"52","author":"Cervera V","year":"2011","unstructured":"Cervera V, Mai W, Vite CH, Johnson V, Dayrell-Hart B, Seiler GS. Comparative magnetic resonance imaging findings between gliomas and presumed cerebrovascular accidents in dogs. Vet Radiol Ultrasound. 2011;52(1):33\u201340. doi:10.1111\/j.1740-8261.2010.01749.x"},{"issue":"5","key":"B2","series-title":"Vet Radiol Ultrasound","first-page":"384","article-title":"Utility of magnetic resonance imaging for distinguishing neoplastic from non-neoplastic brain lesions in dogs and cats","volume":"46","author":"Cherubini GB","year":"2005","unstructured":"Cherubini GB, Mantis P, Martinez TA, Lamb CR, Cappello R. Utility of magnetic resonance imaging for distinguishing neoplastic from non-neoplastic brain lesions in dogs and cats. Vet Radiol Ultrasound. 2005;46(5):384\u2013387. doi:10.1111\/j.1740-8261.2005.00069.x"},{"issue":"3","key":"B3","series-title":"J Vet Intern Med","first-page":"589","article-title":"Magnetic resonance imaging for the differentiation of neoplastic, inflammatory, and cerebrovascular brain disease in dogs","volume":"26","author":"Wolff CA","year":"2012","unstructured":"Wolff CA, Holmes SP, Young BD, et al. Magnetic resonance imaging for the differentiation of neoplastic, inflammatory, and cerebrovascular brain disease in dogs. J Vet Intern Med. 2012;26(3):589\u2013597. doi:10.1111\/j.1939-1676.2012.00899.x"},{"issue":"3","key":"B4","series-title":"J Neurooncol","first-page":"553","article-title":"Readmission risk of malignant brain tumor patients undergoing laser interstitial thermal therapy (LITT) and stereotactic needle biopsy (SNB): a covariate balancing weights analysis of the National Readmissions Database (NRD)","volume":"159","author":"Do TH","year":"2022","unstructured":"Do TH, Howard MA, Palzer EF, et al. Readmission risk of malignant brain tumor patients undergoing laser interstitial thermal therapy (LITT) and stereotactic needle biopsy (SNB): a covariate balancing weights analysis of the National Readmissions Database (NRD). J Neurooncol. 2022;159(3):553\u2013561. doi:10.1007\/s11060-022-04093-6"},{"issue":"1","key":"B5","series-title":"Neurosurg Rev","first-page":"5","article-title":"Advances, technological innovations, and future prospects in stereotactic brain biopsies","volume":"46","author":"Bex A","year":"2022","unstructured":"Bex A, Mathon B. Advances, technological innovations, and future prospects in stereotactic brain biopsies. Neurosurg Rev. 2022;46(1):5. doi:10.1007\/s10143-022-01918-w"},{"issue":"1","key":"B6","series-title":"Neurosurg Rev","first-page":"661","article-title":"Outpatient stereotactic brain biopsies","volume":"45","author":"Mathon B","year":"2022","unstructured":"Mathon B, Marijon P, Riche M, Degos V, Carpentier A; PSL BRAIN-BIOPSY STUDY GROUP. Outpatient stereotactic brain biopsies. Neurosurg Rev. 2022;45(1):661\u2013671. doi:10.1007\/s10143-021-01593-3"},{"issue":"5","key":"B7","series-title":"J Comput Assist Tomogr","first-page":"1036","article-title":"Three-dimensional CT scanning of the dog brain","volume":"6","author":"Ostertag CB","year":"1982","unstructured":"Ostertag CB, Weigel K. Three-dimensional CT scanning of the dog brain. J Comput Assist Tomogr. 1982;6(5):1036\u20131037. doi:10.1097\/00004728-198210000-00035"},{"issue":"1-6","key":"B8","series-title":"Appl Neurophysiol","first-page":"81","article-title":"Animal research stereotactic instrument modified for computed tomographic guidance","volume":"50","author":"Coffey RJ","year":"1987","unstructured":"Coffey RJ, Lundsford LD. Animal research stereotactic instrument modified for computed tomographic guidance. Appl Neurophysiol. 1987;50(1-6):81\u201386. doi:10.1159\/000100689"},{"key":"B9","series-title":"Prog Vet Neu-Rol","first-page":"41","article-title":"Computed tomographic-guided, free-hand needle biopsy of brain tumors in dogs","volume":"4","author":"Harari J","year":"1994","unstructured":"Harari J, Moore MM, Leathers CW, et al. Computed tomographic-guided, free-hand needle biopsy of brain tumors in dogs. Prog Vet Neu-Rol. 1994;4:41\u201344."},{"issue":"5","key":"B10","series-title":"Vet Radiol Ultrasound","first-page":"424","article-title":"Modification and application of a pelorus mark III stereotactic system for CT-guided brain biopsy in 50 dogs","volume":"40","author":"Koblik PD","year":"1999","unstructured":"Koblik PD, LeCouteur RA, Higgins RJ, et al. Modification and application of a pelorus mark III stereotactic system for CT-guided brain biopsy in 50 dogs. Vet Radiol Ultrasound. 1999;40(5):424\u2013433. doi:10.1111\/j.1740-8261.1999.tb00370.x"},{"issue":"5","key":"B11","series-title":"Vet Radiol Ultrasound","first-page":"434","article-title":"CT-guided brain biopsy using a modified pelorus mark III stereotactic system: experience with 50 dogs","volume":"40","author":"Koblik PD","year":"1999","unstructured":"Koblik PD, LeCouteur RA, Higgins RJ, et al. CT-guided brain biopsy using a modified pelorus mark III stereotactic system: experience with 50 dogs. Vet Radiol Ultrasound. 1999;40(5):434\u2013440. doi:10.1111\/j.1740-8261.1999.tb00371.x"},{"issue":"3","key":"B12","series-title":"Res Vet Sci","first-page":"243","article-title":"Accuracy testing of a new stereotactic CT-guided brain biopsy device in the dog","volume":"68","author":"Moissonnier P","year":"2000","unstructured":"Moissonnier P, Bordeau W, Delisle F, Devauchelle P. Accuracy testing of a new stereotactic CT-guided brain biopsy device in the dog. Res Vet Sci. 2000;68(3):243\u2013247. doi:10.1053\/rvsc.1999.0370"},{"issue":"5","key":"B13","series-title":"Vet Radiol Ultrasound","first-page":"229","article-title":"A new device for stereotactic CT-guided biopsy of the canine brain: design, construction, and needle placement accuracy","volume":"43","author":"Giroux A","year":"2002","unstructured":"Giroux A, Jones JC, Bohn JH, Duncan RB, Waldron DR, Inzana K. A new device for stereotactic CT-guided biopsy of the canine brain: design, construction, and needle placement accuracy. Vet Radiol Ultrasound. 2002;43(5):229\u2013236. doi:10.1111\/j.1740-8261.2002.tb00995.x"},{"issue":"7","key":"B14","series-title":"AJNR Am J Neuroradiol","first-page":"1160","article-title":"Use of a disposable real-time CT stereotactic navigator device for minimally invasive dog brain biopsy through a mini-burr hole","volume":"23","author":"Flegel T","year":"2002","unstructured":"Flegel T, Podell M, March PA, Chakeres DW. Use of a disposable real-time CT stereotactic navigator device for minimally invasive dog brain biopsy through a mini-burr hole. AJNR Am J Neuroradiol. 2002;23(7):1160\u20131163."},{"issue":"4","key":"B15","series-title":"J Vet Intern Med","first-page":"969","article-title":"Diagnostic yield and adverse effects of MRI-guided free-hand brain biopsies through a mini-burr hole in dogs with encephalitis","volume":"26","author":"Flegel T","year":"2012","unstructured":"Flegel T, Oevermann A, Oechtering G, Matiasek K. Diagnostic yield and adverse effects of MRI-guided free-hand brain biopsies through a mini-burr hole in dogs with encephalitis. J Vet Intern Med. 2012;26(4):969\u2013976. doi:10.1111\/j.1939-1676.2012.00961.x"},{"issue":"3","key":"B16","series-title":"J Small Anim Pract","first-page":"115","article-title":"Stereotactic CT-guided brain biopsy in the dog","volume":"43","author":"Moissonnier P","year":"2002","unstructured":"Moissonnier P, Blot S, Devauchelle P, et al. Stereotactic CT-guided brain biopsy in the dog. J Small Anim Pract. 2002;43(3):115\u2013123. doi:10.1111\/j.1748-5827.2002.tb00041.x"},{"key":"B17","first-page":"420","article-title":"Frameless stereotactic CT-guided needle brain biopsy in dogs","volume":"19","author":"Adamo PF","year":"2005","unstructured":"Adamo PF, Lang AS. Frameless stereotactic CT-guided needle brain biopsy in dogs. In: Proceedings of the American College of Veterinary Internal Medicine Forum. American College of Veterinary Internal Medicine; 2005;19:420. doi:10.1111\/j.1939-1676.2005.tb02714.x"},{"issue":"5","key":"B18","series-title":"Vet Radiol Ultrasound","first-page":"438","article-title":"CT-guided stereotactic brain biopsy using the Kopf stereotactic system","volume":"49","author":"Troxel MT","year":"2008","unstructured":"Troxel MT, Vite CH. CT-guided stereotactic brain biopsy using the Kopf stereotactic system. Vet Radiol Ultrasound. 2008;49(5):438\u2013443. doi:10.1111\/j.1740-8261.2008.00403.x"},{"issue":"1","key":"B19","series-title":"Am J Vet Res","first-page":"109","article-title":"Evaluation of minimally invasive excisional brain biopsy and intracranial brachytherapy catheter placement in dogs","volume":"72","author":"Packer RA","year":"2011","unstructured":"Packer RA, Freeman LJ, Miller MA, Fauber AE, Morrison WB. Evaluation of minimally invasive excisional brain biopsy and intracranial brachytherapy catheter placement in dogs. Am J Vet Res. 2011;72(1):109\u2013121. doi:10.2460\/ajvr.72.1.10d"},{"issue":"2","key":"B20","series-title":"Vet Radiol Ultrasound","first-page":"150","article-title":"Description and validation of a magnetic resonance imaging-guided stereotactic brain biopsy device in the dog","volume":"53","author":"Chen AV","year":"2012","unstructured":"Chen AV, Wininger FA, Frey S, et al. Description and validation of a magnetic resonance imaging-guided stereotactic brain biopsy device in the dog. Vet Radiol Ultrasound. 2012;53(2):150\u2013156. doi:10.1111\/j.1740-8261.2011.01889.x"},{"issue":"4","key":"B21","series-title":"Vet Radiol Ultrasound","first-page":"332","article-title":"Application and machine accuracy of a new frameless computed-tomography-guided stereotactic system in dogs","volume":"54","author":"Taylor AR","year":"2013","unstructured":"Taylor AR, Cohen ND, Fletcher S, Griffin JF, Levine JM. Application and machine accuracy of a new frameless computed-tomography-guided stereotactic system in dogs. Vet Radiol Ultrasound. 2013;54(4):332\u2013342. doi:10.1111\/vru.12025"},{"key":"B22","series-title":"J Med Eng","first-page":"139535","article-title":"A simple and inexpensive stereotactic guidance frame for MRI-guided brain biopsy in canines","volume":"2014","author":"Squires AD","year":"2014","unstructured":"Squires AD, Gao Y, Taylor SF, Kent M, Tse ZTH. A simple and inexpensive stereotactic guidance frame for MRI-guided brain biopsy in canines. J Med Eng. 2014;2014:139535. doi:10.1155\/2014\/139535"},{"key":"B23","series-title":"Front Vet Sci","first-page":"20","article-title":"Frame-based stereotactic biopsy of canine brain masses: technique and clinical results in 26 cases","volume":"2","author":"Rossmeisl JH","year":"2015","unstructured":"Rossmeisl JH, Andriani RT, Cecere TE, et al. Frame-based stereotactic biopsy of canine brain masses: technique and clinical results in 26 cases. Front Vet Sci. 2015;2:20. doi:10.3389\/fvets.2015.00020"},{"issue":"5","key":"B24","series-title":"Vet Surg","first-page":"621","article-title":"An easy to produce and economical three-dimensional brain phantom for stereotactic computed tomographic-guided brain biopsy training in the dog","volume":"46","author":"Sidhu DS","year":"2017","unstructured":"Sidhu DS, Ruth JD, Lambert G, Rossmeisl JH. An easy to produce and economical three-dimensional brain phantom for stereotactic computed tomographic-guided brain biopsy training in the dog. Vet Surg. 2017;46(5):621\u2013630. doi:10.1111\/vsu.12657"},{"issue":"11","key":"B25","series-title":"J Small Anim Pract","first-page":"615","article-title":"Novel MRI and CT compatible stereotactic brain biopsy system in dogs using patient-specific facemasks","volume":"58","author":"James MD","year":"2017","unstructured":"James MD, Bova FJ, Rajon DA, Carrera-Justiz S, Clemmons RM. Novel MRI and CT compatible stereotactic brain biopsy system in dogs using patient-specific facemasks. J Small Anim Pract. 2017;58(11):615\u2013621. doi:10.1111\/jsap.12705"},{"issue":"2","key":"B26","series-title":"J Vet Intern Med","first-page":"844","article-title":"Accuracy of a magnetic resonance imaging-based 3D printed stereotactic brain biopsy device in dogs","volume":"34","author":"Gutmann S","year":"2020","unstructured":"Gutmann S, Winkler D, M\u00fcller M, et al. Accuracy of a magnetic resonance imaging-based 3D printed stereotactic brain biopsy device in dogs. J Vet Intern Med. 2020;34(2):844\u2013851. doi:10.1111\/jvim.15739"},{"issue":"3","key":"B27","series-title":"J Vet Intern Med","first-page":"1384","article-title":"Diagnostic accuracy of stereotactic brain biopsy for intracranial neoplasia in dogs: comparison of biopsy, surgical resection, and necropsy specimens","volume":"33","author":"Kani Y","year":"2019","unstructured":"Kani Y, Cecere TE, Lahmers K, et al. Diagnostic accuracy of stereotactic brain biopsy for intracranial neoplasia in dogs: comparison of biopsy, surgical resection, and necropsy specimens. J Vet Intern Med. 2019;33(3):1384\u20131391. doi:10.1111\/jvim.15500"},{"issue":"5","key":"B28","series-title":"Vet Surg","first-page":"933","article-title":"Feasibility and accuracy of 3D printed patient-specific skull contoured brain biopsy guides","volume":"50","author":"Shinn R","year":"2021","unstructured":"Shinn R, Park C, DeBose K, Hsu FC, Cecere T, Rossmeisl J. Feasibility and accuracy of 3D printed patient-specific skull contoured brain biopsy guides. Vet Surg. 2021;50(5):933\u2013943. doi:10.1111\/vsu.13641"},{"key":"B29","series-title":"Front Vet Sci","first-page":"876741","article-title":"Case report: clinical use of a patient-individual magnetic resonance imaging-based stereotactic navigation device for brain biopsies in three dogs","volume":"9","author":"Gutmann S","year":"2022","unstructured":"Gutmann S, Flegel T, M\u00fcller M, et al. Case report: clinical use of a patient-individual magnetic resonance imaging-based stereotactic navigation device for brain biopsies in three dogs. Front Vet Sci. 2022;9:876741. doi:10.3389\/fvets.2022.876741"},{"issue":"3","key":"B30","series-title":"Neuropathology","first-page":"207","article-title":"Accuracy and diagnostic yield of stereotactic biopsy in the diagnosis of brain masses: comparison of results of biopsy and resected surgical specimens","volume":"25","author":"Aker FV","year":"2005","unstructured":"Aker FV, Hakan T, Karadereler S, Erkan M. Accuracy and diagnostic yield of stereotactic biopsy in the diagnosis of brain masses: comparison of results of biopsy and resected surgical specimens. Neuropathology. 2005;25(3):207\u2013213. doi:10.1111\/j.1440-1789.2005.00634.x"},{"issue":"1","key":"B31","series-title":"J Neurooncol","first-page":"139","article-title":"Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle","volume":"93","author":"Owen CM","year":"2009","unstructured":"Owen CM, Linskey ME. Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle. J Neurooncol. 2009;93(1):139\u2013149. doi:10.1007\/s11060-009-9871-y"},{"issue":"4","key":"B32","series-title":"Neurol Res","first-page":"358","article-title":"Accuracy of frameless and frame-based image-guided stereotactic brain biopsy in the diagnosis of glioma: comparison of biopsy and open resection specimen","volume":"27","author":"Woodworth G","year":"2005","unstructured":"Woodworth G, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD. Accuracy of frameless and frame-based image-guided stereotactic brain biopsy in the diagnosis of glioma: comparison of biopsy and open resection specimen. Neurol Res. 2005;27(4):358\u2013362. doi:10.1179\/016164105x40057"},{"key":"B33","series-title":"Clin Neurol Neurosurg","first-page":"101","article-title":"How is stereotactic brain biopsy evolving? A multicentric analysis of a series of 421 cases treated in Rome over the last sixteen years","volume":"174","author":"Callovini GM","year":"2018","unstructured":"Callovini GM, Telera S, Sherkat S, Sperduti I, Callovini T, Carapella CM. How is stereotactic brain biopsy evolving? A multicentric analysis of a series of 421 cases treated in Rome over the last sixteen years. Clin Neurol Neurosurg. 2018;174:101\u2013107. doi:10.1016\/j.clineuro.2018.09.020"},{"issue":"2","key":"B34","series-title":"Neurosurgery","first-page":"160","article-title":"Stereotactic biopsy in the diagnosis of brain masses: comparison of results of biopsy and resected surgical specimen","volume":"24","author":"Chandrasoma PT","year":"1989","unstructured":"Chandrasoma PT, Smith MM, Apuzzo ML. Stereotactic biopsy in the diagnosis of brain masses: comparison of results of biopsy and resected surgical specimen. Neurosurgery. 1989;24(2):160\u2013165. doi:10.1227\/00006123-198902000-00002"},{"issue":"2-4","key":"B35","series-title":"Stereotact Funct Neurosurg","first-page":"136","article-title":"The relationship of imaging techniques to the accuracy of frameless stereotaxy","volume":"72","author":"Schulder M","year":"1999","unstructured":"Schulder M, Fontana P, Lavenhar MA, Carmel PW. The relationship of imaging techniques to the accuracy of frameless stereotaxy. Stereotact Funct Neurosurg. 1999;72(2-4):136\u2013141. doi:10.1159\/000029713"},{"key":"B36","series-title":"In Pract","first-page":"546","article-title":"CT and MRI in veterinary patients: an update on recent advances","volume":"35","author":"Labruy\u00e8re J","year":"2013","unstructured":"Labruy\u00e8re J, Schwarz T. CT and MRI in veterinary patients: an update on recent advances. In Pract. 2013;35:546\u2013563. doi:10.1136\/inp.f6720"},{"issue":"5","key":"B37","series-title":"J Vet Intern Med","first-page":"2021","article-title":"Risk factors for adverse events occurring after recovery from stereotactic brain biopsy in dogs with primary intracranial neoplasia","volume":"34","author":"Shinn RL","year":"2020","unstructured":"Shinn RL, Kani Y, Hsu FC, Rossmeisl JH. Risk factors for adverse events occurring after recovery from stereotactic brain biopsy in dogs with primary intracranial neoplasia. J Vet Intern Med. 2020;34(5):2021\u20132028. doi:10.1111\/jvim.15885"},{"issue":"6","key":"B38","series-title":"J Neurosurg","first-page":"892","article-title":"Clinical and economic consequences of early discharge of patients following supratentorial stereotactic brain biopsy","volume":"94","author":"Kaakaji W","year":"2001","unstructured":"Kaakaji W, Barnett GH, Bernhard D, Warbel A, Valaitis K, Stamp S. Clinical and economic consequences of early discharge of patients following supratentorial stereotactic brain biopsy. J Neurosurg. 2001;94(6):892\u2013898. doi:10.3171\/jns.2001.94.6.0892"}],"container-title":["American Journal of Veterinary Research"],"original-title":[],"link":[{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/85\/9\/ajvr.24.04.0122.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/85\/9\/ajvr.24.04.0122.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/85\/9\/ajvr.24.04.0122.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T17:25:49Z","timestamp":1727803549000},"score":1,"resource":{"primary":{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/85\/9\/ajvr.24.04.0122.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,1]]},"references-count":38,"journal-issue":{"issue":"9"},"URL":"https:\/\/doi.org\/10.2460\/ajvr.24.04.0122","relation":{},"ISSN":["0002-9645","1943-5681"],"issn-type":[{"type":"print","value":"0002-9645"},{"type":"electronic","value":"1943-5681"}],"subject":[],"published":{"date-parts":[[2024,9,1]]}}}