{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T02:37:10Z","timestamp":1770172630141,"version":"3.49.0"},"reference-count":46,"publisher":"American Veterinary Medical Association (AVMA)","issue":"2","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["ajvr"],"published-print":{"date-parts":[[2026,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec id=\"sc_a1\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the agreement between linear deflection oscillometry (LDO) and Doppler ultrasonography (DU) for measuring systolic arterial pressure (SAP) in nonsedated dogs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sc_a2\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Prospective, cross-sectional study, conducted at 2 veterinary teaching hospitals. The study included nonsedated, hospitalized dogs classified by DU SAP as normotensive (90 to 160 mm Hg), hypotensive (&lt; 90 mm Hg), or hypertensive (&gt; 160 mm Hg). The SAP was measured using both DU and LDO.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sc_a3\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      60 dogs were included (29 normotensive, 17 hypotensive, 14 hypertensive). Passing-Bablok regression demonstrated a significant systematic (intercept, 17.6; 95% CI, 7.4 to 29.7;\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .01) and proportional bias (slope, 0.81; 95% CI, 0.71 to 0.92;\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .01), indicating progressively larger differences between DU and LDO at higher SAP values. Bland-Altman analysis showed a bias of \u22123.0 \u00b1 8.49 mm Hg (limits of agreement [LoA], \u221219.66 to 13.64) in hypotensive dogs, 1.66 \u00b1 11.96 mm Hg (LoA, \u221221.8 to 25.1) in normotensive dogs, and 26.7 \u00b1 26.17 mm Hg (LoA, \u221224.77 to 78.2) in hypertensive. Receiver operating characteristic analysis suggested LDO thresholds of 93 mm Hg for DU SAP &lt; 90 mm Hg (AUC, 0.994;\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .0001) and 143 mm Hg for DU SAP &gt; 160 mm Hg (AUC, 0.891;\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .0001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sc_a4\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>LDO and DU demonstrated acceptable agreement in normotensive and hypotensive dogs but weak concordance in hypertensive.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"sc_a5\">\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>LDO may be a practical alternative to DU in normotensive and hypotensive states, but caution is warranted in hypertensive patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.2460\/ajvr.25.07.0234","type":"journal-article","created":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T14:30:35Z","timestamp":1761661835000},"source":"Crossref","is-referenced-by-count":0,"title":["Concordance between linear deflection oscillometry and Doppler decreases as systolic arterial pressure increases in conscious dogs"],"prefix":"10.2460","volume":"87","author":[{"given":"Matheus M.","family":"Mantovani","sequence":"first","affiliation":[{"name":"Faculty of Veterinary Medicine and Animal Science, Federal University of Uberl\u00e2ndia, Uberl\u00e2ndia, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juliana A.","family":"Favato","sequence":"additional","affiliation":[{"name":"School of Veterinary Medicine, Federal University of Minas Gerais, Belo Horizonte, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Any C. A.","family":"Costa","sequence":"additional","affiliation":[{"name":"Faculty of Veterinary Medicine and Animal Science, Federal University of Uberl\u00e2ndia, Uberl\u00e2ndia, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suzana A.","family":"Tsuruta","sequence":"additional","affiliation":[{"name":"Faculty of Veterinary Medicine and Animal Science, Federal University of Uberl\u00e2ndia, Uberl\u00e2ndia, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eduardo M.","family":"Vilela","sequence":"additional","affiliation":[{"name":"Faculty of Veterinary Medicine and Animal Science, Federal University of Uberl\u00e2ndia, Uberl\u00e2ndia, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denise T.","family":"Fantoni","sequence":"additional","affiliation":[{"name":"Faculty of Veterinary Medicine and Animal Science, University of S\u00e3o Paulo, S\u00e3o Paulo, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9964-9242","authenticated-orcid":true,"given":"Luis","family":"Dos Santos","sequence":"additional","affiliation":[{"name":"College of Veterinary Medicine, Purdue University, West Lafayette, IN"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1272","reference":[{"issue":"6","key":"B1","series-title":"J Small Anim Pract","first-page":"318","article-title":"Evaluation of high-definition and conventional oscilometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines","volume":"51","author":"Wernick M","year":"2010","unstructured":"Wernick M, Doherr M, Howard J. Evaluation of high-definition and conventional oscilometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines. J Small Anim Pract. 2010;51(6):318\u2013324. doi:10.1111\/j.1748-5827.2010.00938.x"},{"issue":"3","key":"B2","series-title":"J Vet Intern Med","first-page":"542","article-title":"Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats","volume":"21","author":"Brown S","year":"2007","unstructured":"Brown S, Atkins C, Bagley R, et al. Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats. J Vet Intern Med. 2007;21(3):542\u2013558. doi:10.1111\/j.1939-1676.2007.tb03005.x"},{"key":"B3","series-title":"Res Vet Sci","first-page":"162","article-title":"Evaluation of an oscillometric blood pressure monitor in anesthetized dogs: agreement with direct measurements and ability to detect hypotension","volume":"135","author":"Sedgwick S","year":"2021","unstructured":"Sedgwick S, Lorenzutti AM, Araos JB, Gleed RD, Martin-Flores M. Evaluation of an oscillometric blood pressure monitor in anesthetized dogs: agreement with direct measurements and ability to detect hypotension. Res Vet Sci. 2021;135:162\u2013166. doi:10.1016\/j.rvsc.2021.01.016"},{"issue":"10","key":"B4","series-title":"J Feline Med Surg","first-page":"731","article-title":"Comparison of high definition oscillometric and doppler ultrasonic devices for measuring blood pressure in anaesthetised cats","volume":"12","author":"Petri\u010d AD","year":"2010","unstructured":"Petri\u010d AD, Petra Z, Jerneja S, et al. Comparison of high definition oscillometric and doppler ultrasonic devices for measuring blood pressure in anaesthetised cats. J Feline Med Surg. 2010;12(10):731\u2013737. doi:10.1016\/j.jfms.2010.04.007"},{"key":"B5","series-title":"J Vet Intern Med","first-page":"1803","article-title":"ACVIM consensus statement: guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats","volume":"6","author":"Acierno MJ","year":"2018","unstructured":"Acierno MJ, Brown S, Coleman AE, et al. ACVIM consensus statement: guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats. J Vet Intern Med. 2018;6:1803\u20131822."},{"issue":"2","key":"B6","series-title":"J Feline Med Surg","first-page":"121","article-title":"Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats","volume":"23","author":"Cerna P","year":"2021","unstructured":"Cerna P, Archontakis PE, Cheuk HO, Gunn-Moore DA. Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats. J Feline Med Surg. 2021;23(2):121\u2013130. doi:10.1177\/1098612X20932407"},{"issue":"8","key":"B7","series-title":"J Am Vet Med Assoc","first-page":"962","article-title":"Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs","volume":"240","author":"Wernick MB","year":"2012","unstructured":"Wernick MB, H\u00f6pfner RM, Francey T, Howard J. Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs. J Am Vet Med Assoc. 2012;240(8):962\u2013968. doi:10.2460\/javma.240.8.962"},{"issue":"3","key":"B8","series-title":"Can J Vet Res","first-page":"211","article-title":"Evaluation of oscillometric and doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs","volume":"70","author":"Habermann C","year":"2006","unstructured":"Habermann C, Kang C, Morgan J, Brown SA. Evaluation of oscillometric and doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs. Can J Vet Res. 2006;70(3):211\u2013217."},{"issue":"7","key":"B9","series-title":"Am J Vet Res","first-page":"766","article-title":"Comparison of Doppler ultrasonography and high-definition oscillometry for blood pressure measurements in healthy awake dogs","volume":"71","author":"Chetboul V","year":"2010","unstructured":"Chetboul V, Tissier R, Gouni V, et al. Comparison of Doppler ultrasonography and high-definition oscillometry for blood pressure measurements in healthy awake dogs. Am J Vet Res. 2010;71(7):766\u2013772. doi:10.2460\/ajvr.71.7.766"},{"issue":"5","key":"B10","series-title":"J Am Anim Hosp Assoc","first-page":"300","article-title":"Agreement between Doppler and invasive blood pressure monitoring in anesthetized dogs weighing <5 kg","volume":"51","author":"Kennedy MJ","year":"2015","unstructured":"Kennedy MJ, Barletta M. Agreement between Doppler and invasive blood pressure monitoring in anesthetized dogs weighing <5 kg. J Am Anim Hosp Assoc. 2015;51(5):300\u2013305. doi:10.5326\/JAAHA-MS-6163"},{"issue":"2","key":"B11","series-title":"Vet Anaesth Analg","first-page":"135","article-title":"Validity and reliability of Doppler ultrasonography and direct arterial blood pressure measurements in anaesthetized dogs weighing less than 5 kg","volume":"45","author":"Moll X","year":"2018","unstructured":"Moll X, Aguilar A, Garc\u00eda F, et al. Validity and reliability of Doppler ultrasonography and direct arterial blood pressure measurements in anaesthetized dogs weighing less than 5 kg. Vet Anaesth Analg. 2018;45(2):135\u2013144. doi:10.1016\/j.vaa.2017.08.006"},{"key":"B12","series-title":"Principles of Safety Pharmacology","first-page":"243","article-title":"High definition oscillometry: non-invasive blood pressure measurement and pulse wave analysis","author":"Egner B","year":"2015","unstructured":"Egner B. High definition oscillometry: non-invasive blood pressure measurement and pulse wave analysis. In: Pugsley MK, Curtis MJ, eds. Principles of Safety Pharmacology. Springer Berlin Heidelberg; 2015:243\u2013264."},{"key":"B13","series-title":"Kleintier Konkret\u2013J Small Anim Practitioner","first-page":"18","article-title":"Blood pressure measurement: technology and avoidance of measurement error","volume":"4","author":"Egner B","year":"2006","unstructured":"Egner B. Blood pressure measurement: technology and avoidance of measurement error. Kleintier Konkret\u2013J Small Anim Practitioner. 2006;4:18\u201323."},{"issue":"1","key":"B14","series-title":"Vet Anaesth Analg","first-page":"21","article-title":"Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs","volume":"40","author":"Seli\u0161kar A","year":"2013","unstructured":"Seli\u0161kar A, Zrim\u0161ek P, Sreden\u0161ek J, Petri\u010d AD. Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs. Vet Anaesth Analg. 2013;40(1):21\u201327. doi:10.1111\/j.1467-2995.2012.00774.x"},{"issue":"4","key":"B15","series-title":"J Vet Emerg Crit Care (San Antonio)","first-page":"409","article-title":"Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats","volume":"27","author":"Cerejo SA","year":"2017","unstructured":"Cerejo SA, Teixeira-Neto FJ, Garofalo NA, Rodrigues JC, Celeita-Rodr\u00edguez N, Lagos-Carvajal AP. Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats. J Vet Emerg Crit Care (San Antonio). 2017;27(4):409\u2013418. doi:10.1111\/vec.12623"},{"issue":"1","key":"B16","series-title":"BMC Vet Res","first-page":"52","article-title":"Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits","volume":"14","author":"Bellini L","year":"2018","unstructured":"Bellini L, Veladiano IA, Schrank M, Candaten M, Mollo A. Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits. BMC Vet Res. 2018;14(1):52. doi:10.1186\/s12917-018-1369-4"},{"issue":"2","key":"B17","series-title":"Vet Sci","first-page":"116","article-title":"Agreement and diagnostic accuracy of new linear deflection oscillometry and doppler devices for hypotension detection compared to invasive blood pressure in anesthetized dogs","volume":"12","author":"Mantovani MM","year":"2025","unstructured":"Mantovani MM, Costa AC, de Lima MT, et al. Agreement and diagnostic accuracy of new linear deflection oscillometry and doppler devices for hypotension detection compared to invasive blood pressure in anesthetized dogs. Vet Sci. 2025;12(2):116. doi:10.3390\/vetsci12020116"},{"issue":"2","key":"B18","series-title":"Stat Methods Med Res","first-page":"135","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland JM","year":"1999","unstructured":"Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8(2):135\u2013160. doi:10.1177\/096228029900800204"},{"issue":"3","key":"B19","series-title":"Biometrics","first-page":"837","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong ER","year":"1988","unstructured":"DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988;44(3):837\u2013845. doi:10.2307\/2531595"},{"issue":"4","key":"B20","series-title":"Vet Sci","first-page":"349","article-title":"Evaluation of two veterinary oscillometric noninvasive blood pressure (NIBP) measurement devices (petMAP graphic II and high-definition oscillometry) in dogs","volume":"12","author":"Walter H","year":"2025","unstructured":"Walter H, K\u00e4stner SBR, Amon T, T\u00fcnsmeyer JMA. Evaluation of two veterinary oscillometric noninvasive blood pressure (NIBP) measurement devices (petMAP graphic II and high-definition oscillometry) in dogs. Vet Sci. 2025;12(4):349. doi:10.3390\/vetsci12040349"},{"issue":"2","key":"B21","series-title":"Am J Vet Res","first-page":"205","article-title":"Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs","volume":"59","author":"Grosenbaugh D","year":"1998","unstructured":"Grosenbaugh D, Muir W III. Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs. Am J Vet Res. 1998;59(2):205\u2013212. doi:10.2460\/ajvr.1998.59.02.205"},{"issue":"1","key":"B22","series-title":"Vet Anaesth Analg","first-page":"13","article-title":"Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs","volume":"35","author":"Deflandre CJ","year":"2008","unstructured":"Deflandre CJ, Hellebrekers LJ. Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs. Vet Anaesth Analg. 2008;35(1):13\u201321. doi:10.1111\/j.1467-2995.2007.00346.x"},{"issue":"5","key":"B23","series-title":"J Am Vet Med Assoc","first-page":"651","article-title":"Comparison of blood pressure measurements obtained in dogs by use of indirect oscillometry in a veterinary clinic versus at home","volume":"210","author":"Kallet AJ","year":"1997","unstructured":"Kallet AJ, Cowgill LD, Kass PH. Comparison of blood pressure measurements obtained in dogs by use of indirect oscillometry in a veterinary clinic versus at home. J Am Vet Med Assoc. 1997;210(5):651\u2013654. doi:10.2460\/javma.1997.210.05.651"},{"issue":"6","key":"B1","series-title":"J Small Anim Pract","first-page":"318","article-title":"Evaluation of high-definition and conventional oscilometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines","volume":"51","author":"Wernick M","year":"2010","unstructured":"Wernick M, Doherr M, Howard J. Evaluation of high-definition and conventional oscilometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines. J Small Anim Pract. 2010;51(6):318\u2013324. doi:10.1111\/j.1748-5827.2010.00938.x"},{"issue":"3","key":"B2","series-title":"J Vet Intern Med","first-page":"542","article-title":"Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats","volume":"21","author":"Brown S","year":"2007","unstructured":"Brown S, Atkins C, Bagley R, et al. Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats. J Vet Intern Med. 2007;21(3):542\u2013558. doi:10.1111\/j.1939-1676.2007.tb03005.x"},{"key":"B3","series-title":"Res Vet Sci","first-page":"162","article-title":"Evaluation of an oscillometric blood pressure monitor in anesthetized dogs: agreement with direct measurements and ability to detect hypotension","volume":"135","author":"Sedgwick S","year":"2021","unstructured":"Sedgwick S, Lorenzutti AM, Araos JB, Gleed RD, Martin-Flores M. Evaluation of an oscillometric blood pressure monitor in anesthetized dogs: agreement with direct measurements and ability to detect hypotension. Res Vet Sci. 2021;135:162\u2013166. doi:10.1016\/j.rvsc.2021.01.016"},{"issue":"10","key":"B4","series-title":"J Feline Med Surg","first-page":"731","article-title":"Comparison of high definition oscillometric and doppler ultrasonic devices for measuring blood pressure in anaesthetised cats","volume":"12","author":"Petri\u010d AD","year":"2010","unstructured":"Petri\u010d AD, Petra Z, Jerneja S, et al. Comparison of high definition oscillometric and doppler ultrasonic devices for measuring blood pressure in anaesthetised cats. J Feline Med Surg. 2010;12(10):731\u2013737. doi:10.1016\/j.jfms.2010.04.007"},{"key":"B5","series-title":"J Vet Intern Med","first-page":"1803","article-title":"ACVIM consensus statement: guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats","volume":"6","author":"Acierno MJ","year":"2018","unstructured":"Acierno MJ, Brown S, Coleman AE, et al. ACVIM consensus statement: guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats. J Vet Intern Med. 2018;6:1803\u20131822."},{"issue":"2","key":"B6","series-title":"J Feline Med Surg","first-page":"121","article-title":"Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats","volume":"23","author":"Cerna P","year":"2021","unstructured":"Cerna P, Archontakis PE, Cheuk HO, Gunn-Moore DA. Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats. J Feline Med Surg. 2021;23(2):121\u2013130. doi:10.1177\/1098612X20932407"},{"issue":"8","key":"B7","series-title":"J Am Vet Med Assoc","first-page":"962","article-title":"Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs","volume":"240","author":"Wernick MB","year":"2012","unstructured":"Wernick MB, H\u00f6pfner RM, Francey T, Howard J. Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs. J Am Vet Med Assoc. 2012;240(8):962\u2013968. doi:10.2460\/javma.240.8.962"},{"issue":"3","key":"B8","series-title":"Can J Vet Res","first-page":"211","article-title":"Evaluation of oscillometric and doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs","volume":"70","author":"Habermann C","year":"2006","unstructured":"Habermann C, Kang C, Morgan J, Brown SA. Evaluation of oscillometric and doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs. Can J Vet Res. 2006;70(3):211\u2013217."},{"issue":"7","key":"B9","series-title":"Am J Vet Res","first-page":"766","article-title":"Comparison of Doppler ultrasonography and high-definition oscillometry for blood pressure measurements in healthy awake dogs","volume":"71","author":"Chetboul V","year":"2010","unstructured":"Chetboul V, Tissier R, Gouni V, et al. Comparison of Doppler ultrasonography and high-definition oscillometry for blood pressure measurements in healthy awake dogs. Am J Vet Res. 2010;71(7):766\u2013772. doi:10.2460\/ajvr.71.7.766"},{"issue":"5","key":"B10","series-title":"J Am Anim Hosp Assoc","first-page":"300","article-title":"Agreement between Doppler and invasive blood pressure monitoring in anesthetized dogs weighing <5 kg","volume":"51","author":"Kennedy MJ","year":"2015","unstructured":"Kennedy MJ, Barletta M. Agreement between Doppler and invasive blood pressure monitoring in anesthetized dogs weighing <5 kg. J Am Anim Hosp Assoc. 2015;51(5):300\u2013305. doi:10.5326\/JAAHA-MS-6163"},{"issue":"2","key":"B11","series-title":"Vet Anaesth Analg","first-page":"135","article-title":"Validity and reliability of Doppler ultrasonography and direct arterial blood pressure measurements in anaesthetized dogs weighing less than 5 kg","volume":"45","author":"Moll X","year":"2018","unstructured":"Moll X, Aguilar A, Garc\u00eda F, et al. Validity and reliability of Doppler ultrasonography and direct arterial blood pressure measurements in anaesthetized dogs weighing less than 5 kg. Vet Anaesth Analg. 2018;45(2):135\u2013144. doi:10.1016\/j.vaa.2017.08.006"},{"key":"B12","series-title":"Principles of Safety Pharmacology","first-page":"243","article-title":"High definition oscillometry: non-invasive blood pressure measurement and pulse wave analysis","author":"Egner B","year":"2015","unstructured":"Egner B. High definition oscillometry: non-invasive blood pressure measurement and pulse wave analysis. In: Pugsley MK, Curtis MJ, eds. Principles of Safety Pharmacology. Springer Berlin Heidelberg; 2015:243\u2013264."},{"key":"B13","series-title":"Kleintier Konkret\u2013J Small Anim Practitioner","first-page":"18","article-title":"Blood pressure measurement: technology and avoidance of measurement error","volume":"4","author":"Egner B","year":"2006","unstructured":"Egner B. Blood pressure measurement: technology and avoidance of measurement error. Kleintier Konkret\u2013J Small Anim Practitioner. 2006;4:18\u201323."},{"issue":"1","key":"B14","series-title":"Vet Anaesth Analg","first-page":"21","article-title":"Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs","volume":"40","author":"Seli\u0161kar A","year":"2013","unstructured":"Seli\u0161kar A, Zrim\u0161ek P, Sreden\u0161ek J, Petri\u010d AD. Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs. Vet Anaesth Analg. 2013;40(1):21\u201327. doi:10.1111\/j.1467-2995.2012.00774.x"},{"issue":"4","key":"B15","series-title":"J Vet Emerg Crit Care (San Antonio)","first-page":"409","article-title":"Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats","volume":"27","author":"Cerejo SA","year":"2017","unstructured":"Cerejo SA, Teixeira-Neto FJ, Garofalo NA, Rodrigues JC, Celeita-Rodr\u00edguez N, Lagos-Carvajal AP. Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats. J Vet Emerg Crit Care (San Antonio). 2017;27(4):409\u2013418. doi:10.1111\/vec.12623"},{"issue":"1","key":"B16","series-title":"BMC Vet Res","first-page":"52","article-title":"Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits","volume":"14","author":"Bellini L","year":"2018","unstructured":"Bellini L, Veladiano IA, Schrank M, Candaten M, Mollo A. Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits. BMC Vet Res. 2018;14(1):52. doi:10.1186\/s12917-018-1369-4"},{"issue":"2","key":"B17","series-title":"Vet Sci","first-page":"116","article-title":"Agreement and diagnostic accuracy of new linear deflection oscillometry and doppler devices for hypotension detection compared to invasive blood pressure in anesthetized dogs","volume":"12","author":"Mantovani MM","year":"2025","unstructured":"Mantovani MM, Costa AC, de Lima MT, et al. Agreement and diagnostic accuracy of new linear deflection oscillometry and doppler devices for hypotension detection compared to invasive blood pressure in anesthetized dogs. Vet Sci. 2025;12(2):116. doi:10.3390\/vetsci12020116"},{"issue":"2","key":"B18","series-title":"Stat Methods Med Res","first-page":"135","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland JM","year":"1999","unstructured":"Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8(2):135\u2013160. doi:10.1177\/096228029900800204"},{"issue":"3","key":"B19","series-title":"Biometrics","first-page":"837","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong ER","year":"1988","unstructured":"DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988;44(3):837\u2013845. doi:10.2307\/2531595"},{"issue":"4","key":"B20","series-title":"Vet Sci","first-page":"349","article-title":"Evaluation of two veterinary oscillometric noninvasive blood pressure (NIBP) measurement devices (petMAP graphic II and high-definition oscillometry) in dogs","volume":"12","author":"Walter H","year":"2025","unstructured":"Walter H, K\u00e4stner SBR, Amon T, T\u00fcnsmeyer JMA. Evaluation of two veterinary oscillometric noninvasive blood pressure (NIBP) measurement devices (petMAP graphic II and high-definition oscillometry) in dogs. Vet Sci. 2025;12(4):349. doi:10.3390\/vetsci12040349"},{"issue":"2","key":"B21","series-title":"Am J Vet Res","first-page":"205","article-title":"Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs","volume":"59","author":"Grosenbaugh D","year":"1998","unstructured":"Grosenbaugh D, Muir W III. Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs. Am J Vet Res. 1998;59(2):205\u2013212. doi:10.2460\/ajvr.1998.59.02.205"},{"issue":"1","key":"B22","series-title":"Vet Anaesth Analg","first-page":"13","article-title":"Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs","volume":"35","author":"Deflandre CJ","year":"2008","unstructured":"Deflandre CJ, Hellebrekers LJ. Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs. Vet Anaesth Analg. 2008;35(1):13\u201321. doi:10.1111\/j.1467-2995.2007.00346.x"},{"issue":"5","key":"B23","series-title":"J Am Vet Med Assoc","first-page":"651","article-title":"Comparison of blood pressure measurements obtained in dogs by use of indirect oscillometry in a veterinary clinic versus at home","volume":"210","author":"Kallet AJ","year":"1997","unstructured":"Kallet AJ, Cowgill LD, Kass PH. Comparison of blood pressure measurements obtained in dogs by use of indirect oscillometry in a veterinary clinic versus at home. J Am Vet Med Assoc. 1997;210(5):651\u2013654. doi:10.2460\/javma.1997.210.05.651"}],"container-title":["American Journal of Veterinary Research"],"original-title":[],"link":[{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/87\/2\/ajvr.25.07.0234.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/87\/2\/ajvr.25.07.0234.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/87\/2\/ajvr.25.07.0234.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T13:27:06Z","timestamp":1770125226000},"score":1,"resource":{"primary":{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/87\/2\/ajvr.25.07.0234.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,1]]},"references-count":46,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.2460\/ajvr.25.07.0234","relation":{},"ISSN":["0002-9645","1943-5681"],"issn-type":[{"value":"0002-9645","type":"print"},{"value":"1943-5681","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,1]]}}}