{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T13:48:56Z","timestamp":1775742536162,"version":"3.50.1"},"reference-count":42,"publisher":"American Veterinary Medical Association (AVMA)","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["ajvr"],"published-print":{"date-parts":[[2008,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:p><jats:bold>Objective<\/jats:bold>\u2014To design and manufacture custom titanium bone plates and a custom cutting and drill guide by use of free-form fabrication methods and to compare variables and mechanical properties of 2 canine tibial plateau leveling methods with each other and with historical control values.<\/jats:p>\n<jats:p><jats:bold>Sample Population<\/jats:bold>\u201410 canine tibial replicas created by rapid prototyping methods.<\/jats:p>\n<jats:p><jats:bold>Procedures<\/jats:bold>\u2014Application time, accuracy of correction of the tibial plateau slope (TPS), presence and magnitude of rotational and angular deformation, and replica axial stiffness for 2 chevron wedge osteotomy (CWO) methods were assessed. One involved use of freehand CWO (FHCWO) and screw hole drilling, whereas the other used jig-guided CWO (JGCWO) and screw hole drilling.<\/jats:p>\n<jats:p><jats:bold>Results<\/jats:bold>\u2014Replicas used for FHCWO and JGCWO methods had similar stiffness. Although JGCWO and FHCWO did not weaken the replicas, mean axial stiffness of replicas after JGCWO was higher than after FHCWO. The JGCWO method was faster than the FHCWO method. Mean \u00b1 SD TPS after osteotomy was lower for FHCWO (4.4 \u00b1 1.1\u00b0) than for JGCWO (9.5 \u00b1 0.4\u00b0), and JGCWO was more accurate (target TPS, 8.9\u00b0). Slight varus was evident after FHCWO but not after JGCWO. Mean postoperative rotation after JGCWO and FHCWO did not differ from the target value or between methods.<\/jats:p>\n<jats:p><jats:bold>Conclusions and Clinical Relevance<\/jats:bold>\u2014The JGCWO method was more accurate and more rapid and resulted in more stability than the FHCWO method. Use of custom drill guides could enhance the speed, accuracy, and stability of corrective osteotomies in dogs.<\/jats:p>","DOI":"10.2460\/ajvr.69.7.961","type":"journal-article","created":{"date-parts":[[2008,7,1]],"date-time":"2008-07-01T13:34:11Z","timestamp":1214919251000},"page":"961-966","source":"Crossref","is-referenced-by-count":21,"title":["In vitro evaluation of a custom cutting jig and custom plate for canine tibial plateau leveling"],"prefix":"10.2460","volume":"69","author":[{"given":"Denis J.","family":"Marcellin-Little","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ola L. A.","family":"Harrysson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Omer","family":"Cansizoglu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1272","reference":[{"key":"ref1","series-title":"Sports Med Arthrosc","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1097\/JSA.0b013e3180310a89","article-title":"The role of the high tibial osteotomy in the unstable knee","volume":"15","author":"Giffin","year":"2007"},{"key":"ref2","series-title":"J Am Anim Hosp Assoc","doi-asserted-by":"publisher","first-page":"44","DOI":"10.5326\/0420044","article-title":"Complications associated with 696 tibial plateau leveling osteotomies (2001\u20132003)","volume":"42","author":"Stauffer","year":"2006"},{"key":"ref3","series-title":"Clin Orthop Relat Res","first-page":"19","article-title":"Distraction osteogenesis. A comparison of corticotomy techniques","volume":"301","author":"Frierson","year":"1994"},{"key":"ref4","series-title":"J Long Term Eff Med Implants","first-page":"255","article-title":"A technique for quantifying the performance of oscillating bone saw blades","volume":"7","author":"Ark","year":"1997"},{"key":"ref5","series-title":"Orthopedics","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.3928\/0147-7447-20021101-18","article-title":"Closed-wedge tibial osteotomy: conventional technique versus a new system of compression-dynamic fixation","volume":"25","author":"Tigani","year":"2002"},{"key":"ref6","series-title":"J Formos Med Assoc","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/S0929-6646(09)60308-9","article-title":"Dome-shaped high tibial osteotomy: a long-term follow-up study","volume":"105","author":"Chiang","year":"2006"},{"key":"ref7","series-title":"J Arthroplasty","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/j.arth.2007.01.010","article-title":"Minimally invasive total knee arthroplasty surgery through navigated freehand bone cutting","volume":"22","author":"Haider","year":"2007"},{"key":"ref8","series-title":"Int J Periodontics Restorative Dent","first-page":"493","article-title":"Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 3: stereolithographic drilling guides that do not require bone exposure and the immediate delivery of teeth","volume":"26","author":"Rosenfeld","year":"2006"},{"key":"ref9","series-title":"Int J Periodontics Restorative Dent","first-page":"347","article-title":"Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: rapid-prototype medical modeling and stereolithographic drilling guides requiring bone exposure","volume":"26","author":"Rosenfeld","year":"2006"},{"key":"ref10","series-title":"Clin Oral Implants Res","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1034\/j.1600-0501.2003.140118.x","article-title":"Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers","volume":"14","author":"Van Steenberghe","year":"2003"},{"key":"ref11","series-title":"J Periodontol","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1902\/jop.2005.76.4.503","article-title":"Clinical application of stereolithographic surgical guides for implant placement: preliminary results","volume":"76","author":"Di Giacomo","year":"2005"},{"key":"ref12","series-title":"Int J Oral Maxillofac Implants","first-page":"571","article-title":"Accuracy of implant placement with a stereolithographic surgical guide","volume":"18","author":"Sarment","year":"2003"},{"key":"ref13","series-title":"Int J Periodontics Restorative Dent","first-page":"141","article-title":"Computer-assisted implant placement: scan template, simplant, surgiguide, and SAFE system","volume":"27","author":"Tardieu","year":"2007"},{"key":"ref14","series-title":"Foot Ankle Int","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1177\/107110079601700603","article-title":"Prospective, randomized comparison of proximal crescentic and proximal chevron osteotomies for correction of hallux valgus deformity","volume":"17","author":"Easley","year":"1996"},{"key":"ref15","series-title":"Am J Vet Res","doi-asserted-by":"publisher","first-page":"693","DOI":"10.2460\/ajvr.67.4.693","article-title":"In vitro evaluation of five canine tibial plateau leveling methods","volume":"67","author":"Hildreth","year":"2006"},{"key":"ref16","series-title":"Conf Proc IEEE Eng Med Biol Soc","first-page":"6188","article-title":"Design and biomechanical evaluation of a custom lateral mandible titanium prosthesis","volume":"6","author":"Dongmei","year":"2005"},{"key":"ref17","series-title":"J Craniofac Surg","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1097\/00001665-200209000-00011","article-title":"Craniofacial reconstruction with computer-generated HTR patient-matched implants: use in primary bony tumor excision","volume":"13","author":"Eppley","year":"2002"},{"key":"ref18","series-title":"Advanced manufacturing technology for medical applications","first-page":"193","article-title":"Direct fabrication of custom orthopedic implants using electron beam melting technology","author":"Harrysson","year":"2006"},{"key":"ref19","series-title":"Am J Vet Res","doi-asserted-by":"publisher","first-page":"586","DOI":"10.2460\/ajvr.2003.64.586","article-title":"Comparison of radiographic assessments of the tibial plateau slope in dogs","volume":"64","author":"Baroni","year":"2003"},{"key":"ref20","series-title":"Am J Vet Res","first-page":"915","article-title":"Force plate analysis of the walking gait in healthy dogs","volume":"48","author":"Budsberg","year":"1987"},{"key":"ref21","series-title":"Threaded fasteners material and design","first-page":"153","article-title":"Formulas for torque and preload","author":"Blake","year":"1986"},{"key":"ref22","series-title":"Statistical methods","first-page":"463","article-title":"Appendix A1","author":"Snedecor","year":"1980"},{"key":"ref23","series-title":"Stud Health Technol Inform","first-page":"7","article-title":"New tools for sculpting cranial implants in a shared haptic augmented reality environment","volume":"119","author":"Ai","year":"2006"},{"key":"ref24","series-title":"Stud Health Technol Inform","first-page":"7","article-title":"Cranial implant design using augmented reality immersive system","volume":"125","author":"Ai","year":"2007"},{"key":"ref25","series-title":"J Prosthodont","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1111\/j.1532-849X.2006.00084.x","article-title":"Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report","volume":"15","author":"Lal","year":"2006"},{"key":"ref26","series-title":"J Prosthodont","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1111\/j.1532-849X.2006.00069.x","article-title":"Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept","volume":"15","author":"Lal","year":"2006"},{"key":"ref27","series-title":"ASAIO J","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1097\/00002480-200201000-00004","article-title":"Application of stereolithography for scaffold fabrication for tissue engineered heart valves","volume":"48","author":"Sodian","year":"2002"},{"key":"ref28","series-title":"J Biomed Mater Res","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1002\/jbm.1268","article-title":"Soft and hard tissue response to photocrosslinked poly(propylene fumarate) scaffolds in a rabbit model","volume":"59","author":"Fisher","year":"2002"},{"key":"ref29","series-title":"Monatsh Chem\/Chem Mon","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1007\/s00706-006-0484-2","article-title":"Photopolymers for rapid prototyping of soluble mold materials and molding of cellular biomaterials","volume":"137","author":"Schuster","year":"2006"},{"key":"ref30","series-title":"Monatsh Chem\/Chem Mon","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1007\/s00706-007-0609-2","article-title":"Evaluation of biocompatible photopolymers II: further reactive diluents","volume":"138","author":"Schuster","year":"2007"},{"key":"ref31","series-title":"Acta Orthop Scand","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1080\/00016470410001259-1","article-title":"Navigation in total-knee arthroplasty: CT-based implantation compared with the conventional technique","volume":"75","author":"Perlick","year":"2004"},{"key":"ref32","series-title":"Comput Aided Surg","doi-asserted-by":"publisher","first-page":"77","DOI":"10.3109\/10929080600578925","article-title":"Computer assistance in total knee replacement\u2014a critical assessment of current health care technology","volume":"11","author":"Luring","year":"2006"},{"key":"ref33","series-title":"Proc Inst Mech Eng [H]","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1243\/0954411971534421","article-title":"A new oscillating saw for robotic aided surgery","volume":"211","author":"Moctezuma","year":"1997"},{"key":"ref34","series-title":"J Med Eng Technol","doi-asserted-by":"publisher","first-page":"280","DOI":"10.3109\/03091909809010012","article-title":"Improving accuracy of bone resections using robotics tool holder and a high speed milling cutting tool","volume":"22","author":"Fadda","year":"1998"},{"key":"ref35","series-title":"Scand J Plast Reconstr Surg Hand Surg","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1080\/028443102321096311","article-title":"Microsurgical tissue transfer and individual computer-aided designed and manufactured prefabricated titanium implants for complex craniofacial reconstruction","volume":"36","author":"Eufinger","year":"2002"},{"key":"ref36","series-title":"Rapid Prototyping J","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1108\/13552540510589485","article-title":"Customized design and manufacturing of chin implant based on rapid prototyping","volume":"11","author":"Singare","year":"2005"},{"key":"ref37","series-title":"Rapid Prototyping J","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1108\/13552540610682705","article-title":"Custom fabrication of a composite hemiknee joint based on rapid prototyping","volume":"12","author":"He","year":"2006"},{"key":"ref38","series-title":"Technol Health Care","doi-asserted-by":"publisher","first-page":"413","DOI":"10.3233\/THC-2002-10505","article-title":"Design and manufacturing of cranioplasty implants by 3-axis CNC milling","volume":"10","author":"Hieu","year":"2002"},{"key":"ref39","series-title":"Knee","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/S0968-0160(98)00022-2","article-title":"Custom constrained condylar total knees using CAD-CAM","volume":"6","author":"Sathasivam","year":"1999"},{"key":"ref40","series-title":"Proc Inst Mech Eng [H]","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1243\/PIME_PROC_1992_206_260_02","article-title":"The CADCAM contribution to customized orthopaedic implants","volume":"206","author":"Crawford","year":"1992"},{"key":"ref41","series-title":"Clin Implant Dent Relat Res","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1111\/j.1708-8208.2000.tb00101.x","article-title":"Clinical experiences of CNC-milled titanium frameworks supported by implants in the edentulous jaw: 1year prospective study","volume":"2","author":"Ortorp","year":"2000"},{"key":"ref42","series-title":"Int J Oral Maxillofac Implants","first-page":"782","article-title":"A custom titanium implant-retained single-tooth restoration: a clinical report","volume":"11","author":"Schmitt","year":"1996"}],"container-title":["American Journal of Veterinary Research"],"original-title":[],"link":[{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/69\/7\/ajvr.69.7.961.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/69\/7\/ajvr.69.7.961.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/69\/7\/ajvr.69.7.961.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T12:47:52Z","timestamp":1741351672000},"score":1,"resource":{"primary":{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/69\/7\/ajvr.69.7.961.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,7]]},"references-count":42,"journal-issue":{"issue":"7"},"URL":"https:\/\/doi.org\/10.2460\/ajvr.69.7.961","relation":{},"ISSN":["0002-9645"],"issn-type":[{"value":"0002-9645","type":"print"}],"subject":[],"published":{"date-parts":[[2008,7]]}}}