{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T05:13:20Z","timestamp":1790745200162,"version":"4.1.0"},"reference-count":27,"publisher":"American Veterinary Medical Association (AVMA)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["ajvr"],"published-print":{"date-parts":[[2011,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:p><jats:bold>Objective<\/jats:bold>\u2014To compare electroencephalography (EEG) artifact associated with use of the subdermal wire electrode (SWE), gold cup electrode (GCE), and subdermal needle electrode (SNE) over an 8-hour period in sedated and awake dogs.<\/jats:p>\n<jats:p><jats:bold>Animals<\/jats:bold>\u20146 healthy dogs.<\/jats:p>\n<jats:p><jats:bold>Procedures<\/jats:bold>\u20148 EEG channels were recorded during 20-minute video-EEG recording sessions (intermittently at 0.5, 2, 4, 6, and 8 hours) with and without chlorpromazine sedation. Nonphysiologic artifacts were identified. Duration of artifact was summed for each channel. Number of unaffected channels (NUC) was determined.<\/jats:p>\n<jats:p><jats:bold>Results<\/jats:bold>\u2014NUC was significantly affected by electrode type and sedation over time; median for SWE (2.80 channels; 95% confidence interval [CI], 0.84 to 5.70 channels) was significantly different from medians for GCE (7.87 channels; 95% CI, 7.44 to 7.94 channels) and SNE (7.60 channels; 95% CI, 6.61 to 7.89 channels). After 4 hours, NUC decreased in awake dogs, regardless of electrode type. In awake dogs, duration of artifact differed significantly between SWE and GCE or SNE; medians at 8 hours were 61.55 seconds (95% CI, 21.81 to 173.65 seconds), 1.33 seconds (95% CI, 0.47 to 3.75 seconds), and 21.01 seconds (95% CI, 6.85 to 64.42 seconds), respectively.<\/jats:p>\n<jats:p><jats:bold>Conclusions and Clinical Relevance<\/jats:bold>\u2014The SWE had a significant duration of artifact during recording periods &gt; 2 hours, compared with results for the GCE and SNE, in awake dogs. The GCE, SNE, and sedation resulted in significantly more channels unaffected by artifact. For longer recordings, caution should be exercised in selecting EEG electrodes and sedation state, although differences among electrodes may not be clinically relevant.<\/jats:p>","DOI":"10.2460\/ajvr.72.3.384","type":"journal-article","created":{"date-parts":[[2011,3,2]],"date-time":"2011-03-02T05:12:31Z","timestamp":1299042751000},"page":"384-390","source":"Crossref","is-referenced-by-count":21,"title":["Investigation of the use of three electroencephalographic electrodes for long-term electroencephalographic recording in awake and sedated dogs"],"prefix":"10.2460","volume":"72","author":[{"given":"Fiona M. K.","family":"James","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dana G.","family":"Allen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexa M. E.","family":"Bersenas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. Larry","family":"Grovum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolyn L.","family":"Kerr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabrielle","family":"Monteith","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joane M.","family":"Parent","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Poma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1272","reference":[{"key":"ref1","series-title":"A glossary of terms most commonly used by clinical electroencephalographers and proposal for the report form for the EEG findings. The International Federation of Clinical Neurophysiology","first-page":"21","author":"Noachtar","year":"1999"},{"key":"ref2","series-title":"Electroencephalography: basic principles, clinical applications, and related fields","first-page":"139","article-title":"EEG recording and operation of the apparatus","author":"Reilly","year":"2004"},{"key":"ref3","series-title":"Clin Neurophysiol","doi-asserted-by":"publisher","first-page":"1870","DOI":"10.1016\/j.clinph.2006.04.010","article-title":"Electroencephalographic recording during transcranial magnetic stimulation in humans and animals","volume":"117","author":"Ives","year":"2006"},{"key":"ref4","series-title":"Clin Neurophysiol","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1016\/j.clinph.2006.02.006","article-title":"A comparison of subdermal wire electrodes with collodion-applied disk electrodes in long-term EEG recordings in ICU","volume":"117","author":"Young","year":"2006"},{"key":"ref5","series-title":"Electroencephalography: basic principles, clinical applications, and related fields","first-page":"127","article-title":"Technological basis of EEG recording","author":"Kamp","year":"2004"},{"key":"ref6","series-title":"Magn Reson Med","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1002\/mrm.20357","article-title":"Real-time display of artifact-free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy","volume":"53","author":"Mirsattari","year":"2005"},{"key":"ref7","series-title":"Vet Res Commun","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/BF00343246","article-title":"A survey of current techniques in veterinary electro-diagnostics: EEG, spinal evoked and brainstem auditory evoked potential recording","volume":"12","author":"Steiss","year":"1988"},{"issue":"suppl 3","key":"ref8","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1046\/j.1528-1157.43.s.3.7.x","article-title":"Continuous EEG monitoring in the intensive care unit","volume":"43","author":"Scheuer","year":"2002"},{"key":"ref9","series-title":"J Vet Intern Med","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1111\/j.1939-1676.2006.tb02841.x","article-title":"Use of ketamine for the management of refractory status epilepticus in a dog","volume":"20","author":"Serrano","year":"2006"},{"key":"ref10","series-title":"J Clin Neurophysiol","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1097\/01.WNP.0000152659.30753.47","article-title":"New chronic EEG electrode for critical\/intensive care unit monitoring","volume":"22","author":"Ives","year":"2005"},{"key":"ref11","series-title":"Clin Neurophysiol","doi-asserted-by":"publisher","first-page":"2175","DOI":"10.1016\/j.clinph.2004.04.011","article-title":"MRI compatible EEG electrode system for routine use in the epilepsy monitoring unit and intensive care unit","volume":"115","author":"Mirsattari","year":"2004"},{"key":"ref12","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1111\/j.1528-1167.2007.01240.x","article-title":"EEG monitoring during functional MRI in animal models","volume":"48","author":"Mirsattari","year":"2007"},{"key":"ref13","series-title":"Current practice of clinical electroencephalography","first-page":"271","article-title":"Artifacts","author":"Klem","year":"2003"},{"key":"ref14","series-title":"J Clin Neurophysiol","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1097\/00004691-199901000-00003","article-title":"EEG monitoring in the intensive care unit: pitfalls and caveats","volume":"16","author":"Young","year":"1999"},{"key":"ref15","series-title":"Electroencephalogr Clin Neurophysiol","first-page":"371","article-title":"The ten twenty electrode system of the International Federation","volume":"10","author":"Jasper","year":"1958"},{"key":"ref16","series-title":"Clin Neurophysiol","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1016\/S1388-2457(03)00347-X","article-title":"Canine electroencephalographic recording technique: findings in normal and epileptic dogs","volume":"115","author":"Pellegrino","year":"2004"},{"key":"ref17","series-title":"IEEE Trans Biomed Eng","first-page":"517","article-title":"Automatic elimination of electrode-pop artifacts in EEG's","volume":"33","author":"Barlow","year":"1986"},{"key":"ref18","series-title":"Brain Res","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.brainres.2009.05.052","article-title":"Toward a comparison of microelectrodes for acute and chronic recordings","volume":"1282","author":"Ward","year":"2009"},{"key":"ref19","series-title":"J Nippon Med Sch","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1272\/jnms.72.52","article-title":"Histopathological study of tissue reaction to pacemaker electrodes implanted in the endocardium","volume":"72","author":"Mase","year":"2005"},{"key":"ref20","series-title":"J Vet Intern Med","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1111\/j.1939-1676.2008.0096.x","article-title":"Qualitative and quantitative characteristics of the electroencephalogram in normal horses during spontaneous drowsiness and sleep","volume":"22","author":"Williams","year":"2008"},{"key":"ref21","series-title":"J Small Anim Pract","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1111\/j.1748-5827.1962.tb04189.x","article-title":"The EEG as an aid to diagnosis of nervous diseases in the dog and cat","volume":"3","author":"Croft","year":"1962"},{"key":"ref22","series-title":"J Small Anim Pract","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1111\/j.1748-5827.1967.tb04528.x","article-title":"Postnatal development of the EEG in the dog. I. Introduction and EEG techniques","volume":"8","author":"Fox","year":"1967"},{"key":"ref23","series-title":"Epilepsia","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1111\/j.1528-1157.1970.tb03892.x","article-title":"Comparative clinical and electroencephalographic studies of canine epilepsy","volume":"11","author":"Holliday","year":"1970"},{"key":"ref24","series-title":"Clin Tech Small Anim Pract","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/S1096-2867(98)80034-0","article-title":"Interictal paroxysmal discharges in the electroencephalograms of epileptic dogs","volume":"13","author":"Holliday","year":"1998"},{"key":"ref25","series-title":"Vet Neurol Neurosurg J","first-page":"1","article-title":"Clinical electroencephalography in dogs","volume":"1","author":"Holliday","year":"1999"},{"key":"ref26","series-title":"Am J Vet Res","first-page":"929","article-title":"Effect of chlorpromazine combined with intermittent light stimulation on the electroencephalogram and clinical response of the Beagle dog","volume":"34","author":"Redman","year":"1973"},{"key":"ref27","series-title":"J Small Anim Pract","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1111\/j.1748-5827.1998.tb03665.x","article-title":"Idiopathic epilepsy in 125 dogs: a long-term study. Clinical and electroencephalographic findings","volume":"39","author":"Jaggy","year":"1998"}],"container-title":["American Journal of Veterinary Research"],"original-title":[],"link":[{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/72\/3\/ajvr.72.3.384.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/72\/3\/ajvr.72.3.384.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/ajvr\/72\/3\/ajvr.72.3.384.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T12:25:47Z","timestamp":1741350347000},"score":1,"resource":{"primary":{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/ajvr\/72\/3\/ajvr.72.3.384.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3]]},"references-count":27,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.2460\/ajvr.72.3.384","relation":{},"ISSN":["0002-9645"],"issn-type":[{"value":"0002-9645","type":"print"}],"subject":[],"published":{"date-parts":[[2011,3]]}}}