{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T10:16:51Z","timestamp":1791281811469,"version":"4.1.0"},"reference-count":24,"publisher":"American Veterinary Medical Association (AVMA)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["javma"],"published-print":{"date-parts":[[2012,4,15]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:p><jats:bold>Objective<\/jats:bold>\u2014To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs.<\/jats:p>\n<jats:p><jats:bold>Design<\/jats:bold>\u2014Diagnostic test evaluation.<\/jats:p>\n<jats:p><jats:bold>Animals<\/jats:bold>\u201429 client-owned dogs.<\/jats:p>\n<jats:p><jats:bold>Procedures<\/jats:bold>\u20145 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO).<\/jats:p>\n<jats:p><jats:bold>Results<\/jats:bold>\u2014When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO).<\/jats:p>\n<jats:p><jats:bold>Conclusions and Clinical Relevance<\/jats:bold>\u2014Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.<\/jats:p>","DOI":"10.2460\/javma.240.8.962","type":"journal-article","created":{"date-parts":[[2012,4,3]],"date-time":"2012-04-03T21:33:20Z","timestamp":1333488800000},"page":"962-968","source":"Crossref","is-referenced-by-count":20,"title":["Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs"],"prefix":"10.2460","volume":"240","author":[{"given":"Morena B.","family":"Wernick","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert M.","family":"H\u00f6pfner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thierry","family":"Francey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Judith","family":"Howard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1272","reference":[{"key":"ref1","series-title":"J Vet Intern Med","first-page":"542","article-title":"Guidelines for the identification, evaluation and management of systemic hypertension in dogs and cats","volume":"21","author":"Brown","year":"2007"},{"key":"ref2","series-title":"Vet Anaesth Analg","first-page":"27","article-title":"Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs","volume":"31","author":"Sawyer","year":"2004"},{"key":"ref3","series-title":"Can J Vet Res","first-page":"211","article-title":"Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs","volume":"70","author":"Habermann","year":"2006"},{"key":"ref4","series-title":"Res Vet Sci","first-page":"17","article-title":"Comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in conscious dogs","volume":"61","author":"Bodey","year":"1996"},{"key":"ref5","series-title":"Res Vet Sci","first-page":"265","article-title":"A comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in anaesthetised dogs using tail and limb cuffs","volume":"57","author":"Bodey","year":"1994"},{"key":"ref6","series-title":"Can J Vet Res","first-page":"238","article-title":"Comparison of direct and indirect blood pressure measurements in anesthetized dogs","volume":"59","author":"Gains","year":"1995"},{"key":"ref7","series-title":"Lab Anim Sci","first-page":"134","article-title":"Comparison of direct and indirect blood pressure measurement in anesthetized dogs","volume":"41","author":"Sawyer","year":"1991"},{"key":"ref8","series-title":"J Am Vet Med Assoc","first-page":"1623","article-title":"Clinical comparison of three methods to measure blood pressure in nonsedated dogs","volume":"215","author":"Stepien","year":"1999"},{"key":"ref9","series-title":"Can J Comp Med","first-page":"419","article-title":"Evaluation of the arterial blood pressure of dogs by two noninvasive methods","volume":"49","author":"Chalifoux","year":"1985"},{"key":"ref10","series-title":"Vet Anaesth Analg","first-page":"13","article-title":"Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs","volume":"35","author":"Deflandre","year":"2008"},{"key":"ref11","series-title":"J Am Anim Hosp Assoc","first-page":"471","article-title":"Comparison of the indirect oscillometric and direct arterial methods for blood pressure measurements in anesthetized dogs","volume":"32","author":"Meurs","year":"1996"},{"key":"ref12","series-title":"Am J Vet Res","first-page":"205","article-title":"Accuracy of noninvasive oxyhemoglobin saturation, end-tidal carbon dioxide concentration, and blood pressure monitoring during experimentally induced hypoxemia, hypotension, or hypertension in anesthetized dogs","volume":"59","author":"Grosenbaugh","year":"1998"},{"key":"ref13","series-title":"Am J Vet Res","first-page":"1271","article-title":"Noninvasive measurement of systemic arterial pressure in dogs by automatic sphygmomanometry","volume":"43","author":"Hamlin","year":"1982"},{"key":"ref14","series-title":"J Small Anim Pract","first-page":"318","article-title":"Evaluation of high-definition and conventional oscilometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines","volume":"91","author":"Wernick","year":"2010"},{"key":"ref15","series-title":"Res Vet Sci","first-page":"15","article-title":"Longitudinal studies of reproducibility and variability of indirect (oscillometric) blood pressure measurement in dogs: evidence from tracking","volume":"63","author":"Bodey","year":"1997"},{"key":"ref16","series-title":"J Vet Med Sci","first-page":"449","article-title":"Indirect measurement of systemic blood pressure in conscious dogs in a clinical setting","volume":"70","author":"Hsiang","year":"2008"},{"key":"ref17","series-title":"Am J Vet Res","first-page":"766","article-title":"Comparison of Doppler ultrasonography and high-definition oscillometry for blood pressure measurements in healthy awake dogs","volume":"71","author":"Chetboul","year":"2010"},{"key":"ref18","series-title":"Am J Physiol Heart Circ Physiol","first-page":"H664","article-title":"Indirect mean arterial pressure in the anesthetized dog","volume":"238","author":"Geddes","year":"1980"},{"key":"ref19","series-title":"J Vet Intern Med","first-page":"65","article-title":"Comparative diagnostic test characteristics of oscillometric and Doppler ultrasonographic methods in the detection of systolic hypertension in dogs","volume":"17","author":"Stepien","year":"2003"},{"key":"ref20","series-title":"Am J Vet Res","first-page":"1541","article-title":"Accuracy of an ocsillometric blood pressure monitor during phenylephrine-induced hypertension in dogs","volume":"67","author":"McMurphy","year":"2006"},{"key":"ref21","series-title":"J Vet Med Sci","first-page":"989","article-title":"A clinical evaluation of blood pressure through non-invasive measurement using the oscillometric procedure in conscious dogs","volume":"59","author":"Mishina","year":"1997"},{"key":"ref22","series-title":"ANSI\/AAMI\/ISO 81060\u20131: 2007: non-invasive sphygmomanometers\u2014part 1: requirements and test methods for non-automated measurement type","year":"2008"},{"key":"ref23","series-title":"Statist Med","first-page":"1603","article-title":"Methods for assessing reliability and validity for a measurement tool: a case study and critique using the WHO haemoglobin colour scale","volume":"23","author":"White","year":"2004"},{"key":"ref24","series-title":"Practical statistics for medical research","first-page":"403","article-title":"Inter-rater agreement","author":"Altman","year":"1991"}],"container-title":["Journal of the American Veterinary Medical Association"],"original-title":[],"link":[{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/javma\/240\/8\/javma.240.8.962.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/javma\/240\/8\/javma.240.8.962.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/avmajournals.avma.org\/downloadpdf\/journals\/javma\/240\/8\/javma.240.8.962.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T13:13:22Z","timestamp":1741353202000},"score":1,"resource":{"primary":{"URL":"https:\/\/avmajournals.avma.org\/view\/journals\/javma\/240\/8\/javma.240.8.962.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,4,15]]},"references-count":24,"journal-issue":{"issue":"8"},"URL":"https:\/\/doi.org\/10.2460\/javma.240.8.962","relation":{},"ISSN":["0003-1488"],"issn-type":[{"value":"0003-1488","type":"print"}],"subject":[],"published":{"date-parts":[[2012,4,15]]}}}