{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,9,15]],"date-time":"2022-09-15T04:45:25Z","timestamp":1663217125720},"reference-count":23,"publisher":"Japanese Society for Magnetic Resonance in Medicine","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["MRMS","magn reson med sci"],"published-print":{"date-parts":[[2013]]},"DOI":"10.2463\/mrms.2013-0009","type":"journal-article","created":{"date-parts":[[2013,10,28]],"date-time":"2013-10-28T23:02:06Z","timestamp":1383001326000},"page":"249-259","source":"Crossref","is-referenced-by-count":3,"title":["Usefulness of Dual Echo Volumetric Isotropic Turbo Spin Echo Acquisition (VISTA) in MR Imaging of the Temporomandibular Joint"],"prefix":"10.2463","volume":"12","author":[{"given":"Yuko","family":"SUGIMORI","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shigeko","family":"TANAKA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuya","family":"NISHIMURA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"YAMAMOTO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoko","family":"OHFUJI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukari","family":"NAITO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasutomo","family":"KATSUMATA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukio","family":"MIKI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1295","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Westesson PL. Reliability and validity of imaging diagnosis of temporomandibular joint disorder. Adv Dent Res 1993; 7:137-151.","DOI":"10.1177\/08959374930070020401"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Tasaki MM, Westesson PL. Temporomandibular joint: diagnosing accuracy with sagittal and coronal MR imaging. Radiology 1993; 186:723-729.","DOI":"10.1148\/radiology.186.3.8430181"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Tasaki MM, Westesson PL, Isberg AM, Ren YF, Tallents RH. Classification and prevalence of temporomandibular joint disk displacement in patients and symptom-free volunteers. Am J Orthod Dentofacial Orthop 1996; 109:249-262.","DOI":"10.1016\/S0889-5406(96)70148-8"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. DaSilva AF, Shaefer J, Keith DA. The temporomandibular joint: clinical and surgical aspects. Neuroimaging Clin N Am 2003; 13:573-582.","DOI":"10.1016\/S1052-5149(03)00043-1"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Tasaki MM, Westesson PL, Raubertas RF. Observer variation in interpretation of magnetic resonance images of the temporomandibular joint. Oral Surg Oral Med Oral Pathol 1993; 76:231-234.","DOI":"10.1016\/0030-4220(93)90210-U"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Sano T, Widmalm SE, Yamamoto M, Sakuma K, Araki K, Matsuda Y, Okano T. Usefulness of proton density and T<sub>2<\/sub>-weighted vs. T<sub>1<\/sub>-weighted MRI in diagnoses of TMJ disk status. Cranio 2003; 21:253-258.","DOI":"10.1080\/08869634.2003.11746259"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Orsini MG, Kuboki T, Terada S, Matsuka Y, Yamashita A, Clark GT. Diagnostic value of 4 criteria to interpret temporomandibular joint normal disk position on magnetic resonance images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1998; 86:489-497.","DOI":"10.1016\/S1079-2104(98)90380-8"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Ahmad M, Hollender L, Anderson Q, et al. Research diagnostic criteria for temporomandibular disorders (RDC\/TMD): development of image analysis criteria and examiner reliability for image analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107:844-860.","DOI":"10.1016\/j.tripleo.2009.02.023"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Westesson PL, Brooks SL. Temporomandibular joint: relationship between MR evidence of effusion and the presence of pain and disk displacement. AJR Am J Roentgenol 1992; 159:559-563.","DOI":"10.2214\/ajr.159.3.1503025"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Hayakawa Y, Kober C, Otonari-Yamamoto M, Otonari T, Wakoh M, Sano T. An approach for three-dimensional visualization using high-resolution MRI of the temporomandibular joint. Dentomaxillofac Radiol 2007; 36:341-347.","DOI":"10.1259\/dmfr\/12894471"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Pinkert R, Wandelt T, Kittner T. Comparative study of sagittal and coronal MRI of histological disk and temporomandibular joint specimen for examining an identity of anterior disk dislocation and anterior capsular connective tissue. Mund Kiefer Gesichtschir 2000; 4:285-291. [Article in German]","DOI":"10.1007\/PL00010789"},{"key":"12","unstructured":"12. [Alm&#x103;&#x15f;an OC, Hede&#x15f;iu M, B&#x103;ciu&#x163; G, Leucu&#x163;a DC, B&#x103;ciu&#x163; M. Disk and joint morphology variations on coronal and sagittal MRI in temporomandibular joint disorders]. Clin Oral Investig 2012 Aug 7. [Epub ahead of print]"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Yamada I, Murata Y, Shibuya H, Suzuki S. Internal derangements of the temporomandibular joint: comparison of assessment with three-dimensional gradient echo and spin echo MRI. Neuroradiology 1997; 39:661-667.","DOI":"10.1007\/s002340050487"},{"key":"14","unstructured":"14. Schick RM, Wismer GL, Davis KR. Magnetic susceptibility effects secondary to out-of-plane air in fast MR scanning. AJNR Am J Neuroradiol 1988; 9:439-442."},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Busse RF, Hariharan H, Vu A, Brittain JH. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magn Reson Med 2006; 55:1030-1037.","DOI":"10.1002\/mrm.20863"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Kijowski R, Davis KW, Woods MA, Lindstrom MJ, De Smet AA, Gold GE, Busse RF. Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging-diagnostic performance compared with that of conventional MR imaging at 3.0T. Radiology 2009; 252:486-495.","DOI":"10.1148\/radiol.2523090028"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Busse RF, Brau AC, Vu A, et al. Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 2008; 60:640-649.","DOI":"10.1002\/mrm.21680"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Yoneyama M, Nakamura M, Tabuchi T, Takemura A, Obara M. Optimization of 3D-variable refocusing flip angle RARE imaging for high-resolution volumetric black-blood angiography. Radiol Phys Technol 2012; 5:270-276.","DOI":"10.1007\/s12194-012-0161-6"},{"key":"19","unstructured":"19. Ertl-Wagner BB, Bruening R, Blume J, Hoffmann RT, Mueller-Schunk S, Snyder B, Reiser MF. Relative value of sliding-thin-slab multiplanar reformations and sliding-thin-slab maximum intensity projections as reformatting techniques in multisection CT angiography of the cervicocranial vessels. AJNR Am J Neuroradiol 2006; 27:107-113."},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Prokop M, Shin HO, Schanz A, Schaefer-Prokop CM. Use of maximum intensity projections in CT angiography: a basic review. Radiographics 1997; 17:433-451.","DOI":"10.1148\/radiographics.17.2.9084083"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. Subhas N, Kao A, Freire M, Polster JM, Obuchowski NA, Winalski CS. MRI of the knee ligaments and menisci: comparison of isotropic-resolution 3D and conventional 2D fast spin-echo sequences at 3T. AJR Am J Radiol 2011; 197:442-450.","DOI":"10.2214\/AJR.10.5709"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Henkelman RM, Hardy PA, Bishop JE, Poon CS, Plewes DB. Why fat is bright in RARE and fast spin-echo imaging. J Magn Reson Imaging 1992; 2:533-540.","DOI":"10.1002\/jmri.1880020511"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Melhem ER, Itoh R, Folkers PJ. Cervical spine: three-dimensional fast spin-echo MR imaging-improved recovery of longitudinal magnetization with driven equilibrium pulse. Radiology 2001; 218:283-288.","DOI":"10.1148\/radiology.218.1.r01ja38283"}],"container-title":["Magnetic Resonance in Medical Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/mrms\/12\/4\/12_2013-0009\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,20]],"date-time":"2021-05-20T13:39:29Z","timestamp":1621517969000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/mrms\/12\/4\/12_2013-0009\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2013]]}},"URL":"https:\/\/doi.org\/10.2463\/mrms.2013-0009","relation":{},"ISSN":["1347-3182","1880-2206"],"issn-type":[{"value":"1347-3182","type":"print"},{"value":"1880-2206","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013]]}}}