{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T21:41:14Z","timestamp":1792532474716,"version":"4.5.0"},"reference-count":10,"publisher":"Walter de Gruyter GmbH","issue":"1","license":[{"start":{"date-parts":[[2018,1,19]],"date-time":"2018-01-19T00:00:00Z","timestamp":1516320000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The paper analyzes the conditions of safe use of industrial gas systems and factors influencing gas hazards. Typical gas installation and its basic features have been characterized. The results of gas threat analysis in an industrial enterprise using FTA error tree method and ETA event tree method are presented. Compares selected methods of identifying hazards gas industry with respect to the scope of their use. The paper presents an analysis of two exemplary hazards: an industrial gas catastrophe (FTA) and an explosive gas explosion (ETA). In both cases, technical risks and human errors (human factor) were taken into account. The cause-effect relationships of hazards and their causes are presented in the form of diagrams in the drawings.<\/jats:p>","DOI":"10.2478\/mspe-2018-0003","type":"journal-article","created":{"date-parts":[[2018,1,23]],"date-time":"2018-01-23T17:18:29Z","timestamp":1516727909000},"page":"23-26","source":"Crossref","is-referenced-by-count":8,"title":["Application of the FTA and ETA Method for Gas Hazard Identification for the Performance of Safety Systems in the Industrial Department"],"prefix":"10.2478","volume":"26","author":[{"given":"Jolanta","family":"Ignac-Nowicka","sequence":"first","affiliation":[{"name":"Silesian University of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","published-online":{"date-parts":[[2018,1,19]]},"reference":[{"key":"2026042823121631042_j_mspe-2018-0003_ref_001_w2aab3b7b3b1b6b1ab1ab1Aa","unstructured":"[1] K. Chmielewski, \u201eZasady stosowania stacjonarnych system\u00f3w detekcji gaz\u00f3w\u201d, Ochrona Mienia i Informacji, no. 4, pp. 69-71, 2011."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_002_w2aab3b7b3b1b6b1ab1ab2Aa","unstructured":"[2] J. Ignac-Nowicka, \u201eAir pollution monitoring at the workstand and in the ambient air\u201d, Molecular and Quantum Acoustics, vol. 22, pp. 113-121, 2001."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_003_w2aab3b7b3b1b6b1ab1ab3Aa","unstructured":"[3] J. Ignac-Nowicka, \u201eMonitorowanie mieszanin gazowych dla bezpiecze\u0144stwa procesu produkcji acetylenu\u201d, Studies & Proceedings of Polish Association for Knowledge Management, vol. 40, pp. 170-180, 2011."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_004_w2aab3b7b3b1b6b1ab1ab4Aa","unstructured":"[4] J. Ignac-Nowicka, \u201eZastosowanie sensor\u00f3w w in\u017cynierii bezpiecze\u0144stwa dla rozwoju inteligentnej specjalizacji\u201d, in Bezpiecze\u0144stwo jako determinanta doskonalenia systemu zarz\u0105dzania organizacjami, M. G\u00f3rska and E. Staniewska, Eds. Cz\u0119stochowa: Wydawnictwo Wydzia\u0142u In\u017cynierii Produkcji i Technologii Materia\u0142\u00f3w Politechniki Cz\u0119stochowskiej, 2016, pp. 80-89."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_005_w2aab3b7b3b1b6b1ab1ab5Aa","unstructured":"[5] R. Kalinowski, Monitorowanie zagro\u017ce\u0144. Siedlce: Wyd. Akademii Podlaskiej, 2003."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_006_w2aab3b7b3b1b6b1ab1ab6Aa","unstructured":"[6] PN-EN 1127-1:2001 Atmosfery wybuchowe. Zapobieganie wybuchowi i ochrona przed wybuchem. Poj\u0119cia podstawowe i metodologia, Polski Komitet Normalizacyjny, 2001."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_007_w2aab3b7b3b1b6b1ab1ab7Aa","unstructured":"[7] R. Studenski, Organizacja bezpiecznej pracy w przedsi\u0119biorstwie. Gliwice: Wydawnictwo Politechniki \u015al\u0105skiej."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_008_w2aab3b7b3b1b6b1ab1ab8Aa","unstructured":"[8] M. \u015awier\u017cewski, \u201eUrz\u0105dzenia elektryczne w przestrzeniach zagro\u017conych wybuchem\u201d, Miesi\u0119cznik Elektro. info, no. 9\/10, pp. 8-12, 2007."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_009_w2aab3b7b3b1b6b1ab1ab9Aa","unstructured":"[9] A. W\u00f3jcik, Mechaniczne i elektroniczne systemy zabez-piecze\u0144. Literatura fachowa dla firm i instytucji. Warszawa: Wydawnictwo Verlag Dashofer, 2004."},{"key":"2026042823121631042_j_mspe-2018-0003_ref_010_w2aab3b7b3b1b6b1ab1ac10Aa","unstructured":"[10] W. Nawrocki, Sensory i systemy pomiarowe. Pozna\u0144: Wydawnictwo Politechniki Pozna\u0144skiej, 2006."}],"container-title":["Management Systems in Production Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/content.sciendo.com\/view\/journals\/mspe\/26\/1\/article-p23.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/reference-global.com\/pdf\/10.2478\/mspe-2018-0003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T02:30:05Z","timestamp":1777429805000},"score":1,"resource":{"primary":{"URL":"https:\/\/reference-global.com\/article\/10.2478\/mspe-2018-0003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,19]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,1,19]]},"published-print":{"date-parts":[[2018,3,1]]}},"alternative-id":["10.2478\/mspe-2018-0003"],"URL":"https:\/\/doi.org\/10.2478\/mspe-2018-0003","relation":{},"ISSN":["2450-5781"],"issn-type":[{"value":"2450-5781","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,19]]}}}