{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T00:09:17Z","timestamp":1783901357445,"version":"3.55.0"},"reference-count":45,"publisher":"Walter de Gruyter GmbH","issue":"3","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Administering gadolinium-based contrast agent before electroporation allows the contrast agent to enter the cells and enables MRI assessment of reversibly electroporated regions. The aim of this study was evaluation of contrast agent entrapment in Chinese hamster ovary (CHO) cells and comparison of these results with those determined by standard\n                      <jats:italic>in vitro<\/jats:italic>\n                      methods for assessing cell membrane permeability, cell membrane integrity and cell survival following electroporation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      Cell membrane permeabilization and cell membrane integrity experiments were performed using YO-PRO-1 dye and propidium iodide, respectively. Cell survival experiments were performed by assessing metabolic activity of cells using MTS assay. The entrapment of gadolinium-based contrast agent gadobutrol inside the cells was evaluated using T\n                      <jats:sub>1<\/jats:sub>\n                      relaxometry of cell suspensions 25 min and 24 h after electroporation and confirmed by inductively coupled plasma mass spectrometry.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Contrast agent was detected 25 min and 24 h after the delivery of electric pulses in cells that were reversibly electroporated. In addition, contrast agent was present in irreversibly electroporated cells 25 min after the delivery of electric pulses but was no longer detected in irreversibly electroporated cells after 24 h. Inductively coupled plasma mass spectrometry showed a proportional decrease in gadolinium content per cell with shortening of T\n                      <jats:sub>1<\/jats:sub>\n                      relaxation time (\n                      <jats:italic>R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.88 and\n                      <jats:italic>p<\/jats:italic>\n                      = 0.0191).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      Our results demonstrate that the contrast agent is entrapped in cells exposed to reversible electroporation but exits from cells exposed to irreversible electroporation within 24 h, thus confirming the hypothesis on which detection experiments\n                      <jats:italic>in vivo<\/jats:italic>\n                      were based.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.2478\/raon-2024-0047","type":"journal-article","created":{"date-parts":[[2024,9,27]],"date-time":"2024-09-27T13:16:00Z","timestamp":1727442960000},"page":"406-415","source":"Crossref","is-referenced-by-count":1,"title":["Analysis of magnetic resonance contrast agent entrapment following reversible electroporation\n                    <i>in vitro<\/i>"],"prefix":"10.2478","volume":"58","author":[{"given":"Marko","family":"Strucic","sequence":"first","affiliation":[{"name":"Faculty of Electrical Engineering , University of Ljubljana , Ljubljana , Slovenia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damijan","family":"Miklavcic","sequence":"additional","affiliation":[{"name":"Faculty of Electrical Engineering , University of Ljubljana , Ljubljana , Slovenia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zala","family":"Vidic","sequence":"additional","affiliation":[{"name":"Faculty of Electrical Engineering , University of Ljubljana , Ljubljana , Slovenia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Scuderi","sequence":"additional","affiliation":[{"name":"Faculty of Electrical Engineering , University of Ljubljana , Ljubljana , Slovenia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Igor","family":"Sersa","sequence":"additional","affiliation":[{"name":"Jo\u017eef Stefan Institute , Ljubljana , Slovenia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matej","family":"Kranjc","sequence":"additional","affiliation":[{"name":"Faculty of Electrical Engineering , University of Ljubljana , Ljubljana , Slovenia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","published-online":{"date-parts":[[2024,9,15]]},"reference":[{"key":"2026071211290142246_j_raon-2024-0047_ref_001","doi-asserted-by":"crossref","unstructured":"Kotnik T, Rems L, Tarek M, Miklav\u010di\u010d D. Membrane electroporation and electropermeabilization: Mechanisms and models. Annu Rev Biophys 2019; 48: 63\u201391. doi: 10.1146\/annurev-biophys-052118-115451","DOI":"10.1146\/annurev-biophys-052118-115451"},{"key":"2026071211290142246_j_raon-2024-0047_ref_002","doi-asserted-by":"crossref","unstructured":"Batista Napotnik T, Polaj\u017eer T, Miklav\u010di\u010d D. Cell death due to electroporation \u2013 a review. Bioelectrochemistry 2021; 141: 107871. doi: 10.1016\/j.bioelechem.2021.107871","DOI":"10.1016\/j.bioelechem.2021.107871"},{"key":"2026071211290142246_j_raon-2024-0047_ref_003","doi-asserted-by":"crossref","unstructured":"Aycock KN, Davalos RV. Irreversible electroporation: background, theory, and review of recent developments in clinical oncology. Bioelectricity. 2019; 1: 214\u201334. doi: 10.1089\/bioe.2019.0029","DOI":"10.1089\/bioe.2019.0029"},{"key":"2026071211290142246_j_raon-2024-0047_ref_004","doi-asserted-by":"crossref","unstructured":"Yarmush ML, Golberg A, Ser\u0161a G, Kotnik T, Miklav\u010di\u010d D. Electroporation-based technologies for medicine: principles, applications, and challenges. Annu Rev Biomed Eng 2014; 16: 295\u2013320. doi: 10.1146\/annurev-bioeng-071813-104622","DOI":"10.1146\/annurev-bioeng-071813-104622"},{"key":"2026071211290142246_j_raon-2024-0047_ref_005","doi-asserted-by":"crossref","unstructured":"Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, et al. Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial. Circulation 2023; 147:1422\u201332. doi: 10.1161\/CIRCULATIONAHA.123.063988","DOI":"10.1161\/CIRCULATIONAHA.123.063988"},{"key":"2026071211290142246_j_raon-2024-0047_ref_006","doi-asserted-by":"crossref","unstructured":"Geboers B, Scheffer HJ, Graybill PM, Ruarus AH, Nieuwenhuizen S, Puijk RS, et al. High-voltage electrical pulses in oncology: irreversible electroporation, electrochemotherapy, gene electrotransfer, electrofusion, and electroimmunotherapy. Radiology 2020; 295: 254\u201372. doi: 10.1148\/radiol.2020192190","DOI":"10.1148\/radiol.2020192190"},{"key":"2026071211290142246_j_raon-2024-0047_ref_007","doi-asserted-by":"crossref","unstructured":"\u010corovi\u0107 S, Mir LM, Miklav\u010di\u010d D. In vivo muscle electroporation threshold determination: Realistic numerical models and in vivo experiments. J Membrane Biol 2012; 245: 509\u201320. doi: 10.1007\/s00232-012-9432-8","DOI":"10.1007\/s00232-012-9432-8"},{"key":"2026071211290142246_j_raon-2024-0047_ref_008","doi-asserted-by":"crossref","unstructured":"Smerc R, Ramirez DA, Mahnic-Kalamiza S, Dermol-Cerne J, Sigg DC, Mattison LM, et al. A multiscale computational model of skeletal muscle electroporation validated using in situ porcine experiments. IEEE Trans Biomed Eng 2023; 70: 1\u201312. doi: 10.1109\/TBME.2022.3229560","DOI":"10.1109\/TBME.2022.3229560"},{"key":"2026071211290142246_j_raon-2024-0047_ref_009","doi-asserted-by":"crossref","unstructured":"Kos B, Mattison L, Ramirez D, Cindri\u010d H, Sigg DC, Iaizzo PA, et al. Determination of lethal electric field threshold for pulsed field ablation in ex vivo perfused porcine and human hearts. Front Cardiovasc Med 2023; 10: 1160231. doi: 10.3389\/fcvm.2023.1160231","DOI":"10.3389\/fcvm.2023.1160231"},{"key":"2026071211290142246_j_raon-2024-0047_ref_010","doi-asserted-by":"crossref","unstructured":"Cindric H, Mariappan P, Beyer L, Wiggermann P, Moche M, Miklavcic D, et al. Retrospective study for validation and improvement of numerical treatment planning of irreversible electroporation ablation for treatment of liver tumors. IEEE Trans Biomed Eng 2021; 68: 3513\u201324. doi: 10.1109\/TBME.2021.3075772","DOI":"10.1109\/TBME.2021.3075772"},{"key":"2026071211290142246_j_raon-2024-0047_ref_011","doi-asserted-by":"crossref","unstructured":"Pucihar G, Krmelj J, Reber\u0161ek M, Napotnik T, Miklav\u010di\u010d D. Equivalent pulse parameters for electroporation. IEEE Trans Biomed Eng 2011; 58: 3279\u201388. doi: 10.1109\/TBME.2011.2167232","DOI":"10.1109\/TBME.2011.2167232"},{"key":"2026071211290142246_j_raon-2024-0047_ref_012","doi-asserted-by":"crossref","unstructured":"Kotnik T, Frey W, Sack M, Haberl Megli\u010d S, Peterka M, Miklav\u010di\u010d D. Electroporation-based applications in biotechnology. Trends Biotechnol 2015; 33: 480\u20138. doi: 10.1016\/j.tibtech.2015.06.002","DOI":"10.1016\/j.tibtech.2015.06.002"},{"key":"2026071211290142246_j_raon-2024-0047_ref_013","doi-asserted-by":"crossref","unstructured":"Cemazar M, Jarm T, Miklavcic D, Macek Lebar A, Ihan A, Kopitar AN, et al. Effect of electric-field intensity on electropermeabilization and electro-sensitivity of various tumor-cell lines in vitro. Electro Magnetobiol 1998; 17: 263\u20132.","DOI":"10.3109\/15368379809022571"},{"key":"2026071211290142246_j_raon-2024-0047_ref_014","doi-asserted-by":"crossref","unstructured":"Dermol-\u010cerne J, Miklav\u010di\u010d D, Reber\u0161ek M, Meku\u010d P, Bardet SM, Burke R, et al. Plasma membrane depolarization and permeabilization due to electric pulses in cell lines of different ex-citability. Bioelectrochemistry 2018; 122: 103\u201314. doi: 10.1016\/J.BIOELECHEM.2018.03.011","DOI":"10.1016\/j.bioelechem.2018.03.011"},{"key":"2026071211290142246_j_raon-2024-0047_ref_015","doi-asserted-by":"crossref","unstructured":"Jacobs IV EJ, Campelo SN, Charlton A, Altreuter S, Davalos R V. Characterizing reversible, irreversible, and calcium electroporation to generate a burst-dependent dynamic conductivity curve. Bioelectrochemistry 2024; 155: 108580. doi: 10.1016\/j.bioelechem.2023.108580","DOI":"10.1016\/j.bioelechem.2023.108580"},{"key":"2026071211290142246_j_raon-2024-0047_ref_016","doi-asserted-by":"crossref","unstructured":"Vi\u017eintin A, Vidmar J, \u0160\u010dan\u010dar J, Miklav\u010di\u010d D. Effect of interphase and inter-pulse delay in high-frequency irreversible electroporation pulses on cell survival, membrane permeabilization and electrode material release. Bioelectrochemistry 2020; 134: 107523. doi: 10.1016\/j.bioelechem.2020.107523","DOI":"10.1016\/j.bioelechem.2020.107523"},{"key":"2026071211290142246_j_raon-2024-0047_ref_017","doi-asserted-by":"crossref","unstructured":"Vi\u017eintin A, Markovi\u0107 S, \u0160\u010dan\u010dar J, Miklav\u010di\u010d D. Electroporation with nanosecond pulses and bleomycin or cisplatin results in efficient cell kill and low metal release from electrodes. Bioelectrochemistry 2021; 140: 107798. doi: 10.1016\/j.bioelechem.2021.107798","DOI":"10.1016\/j.bioelechem.2021.107798"},{"key":"2026071211290142246_j_raon-2024-0047_ref_018","doi-asserted-by":"crossref","unstructured":"Poto\u010dnik T, Sachdev S, Polaj\u017eer T, Ma\u010dek Lebar A, Miklav\u010di\u010d D. Efficient gene transfection by electroporation\u2014In vitro and in silico study of pulse parameters. Applied Sciences 2022; 12: 168237. doi: 10.3390\/app12168237.","DOI":"10.3390\/app12168237"},{"key":"2026071211290142246_j_raon-2024-0047_ref_019","unstructured":"Jordan ET, Collins M, Terefe J, Ugozzoli L, Rubio T. Optimizing electroporation conditions in primary and other difficult-to-transfect cells. J Biomol Tech 2008; 19: 328\u201334. PMID: 19183796"},{"key":"2026071211290142246_j_raon-2024-0047_ref_020","doi-asserted-by":"crossref","unstructured":"Jiang C, Davalos R V., Bischof JC. A review of basic to clinical studies of irreversible electroporation herapy. IEEE Trans Biomed Eng 2015; 62: 4\u201320. doi: 10.1109\/TBME.2014.2367543","DOI":"10.1109\/TBME.2014.2367543"},{"key":"2026071211290142246_j_raon-2024-0047_ref_021","doi-asserted-by":"crossref","unstructured":"Pakhomov AG, Shevin R, White JA, Kolb JF, Pakhomova ON, Joshi RP, et al. Membrane permeabilization and cell damage by ultrashort electric field shocks. Arch Biochem Biophys 2007; 465: 109\u201318. doi: 10.1016\/j.abb.2007.05.003","DOI":"10.1016\/j.abb.2007.05.003"},{"key":"2026071211290142246_j_raon-2024-0047_ref_022","doi-asserted-by":"crossref","unstructured":"Sengel JT, Wallace MI. Imaging the dynamics of individual electropores. Proc Natl Acad Sci U S A 2016; 113: 5281\u20136. doi: 10.1073\/pnas.1517437113","DOI":"10.1073\/pnas.1517437113"},{"key":"2026071211290142246_j_raon-2024-0047_ref_023","doi-asserted-by":"crossref","unstructured":"Napotnik TB, Miklav\u010di\u010d D. In vitro electroporation detection methods - an overview. Bioelectrochemistry 2017; 120: 166\u201382. doi: 10.1016\/j.bioelechem.2017.12.005","DOI":"10.1016\/j.bioelechem.2017.12.005"},{"key":"2026071211290142246_j_raon-2024-0047_ref_024","doi-asserted-by":"crossref","unstructured":"Miklav\u010di\u010d D, Beravs K, \u0160emrov D, \u010cema\u017ear M, Dem\u0161ar F, Ser\u0161a G. The importance of electric field distribution for effective in vivo electroporation of tissues. Biophys J 1998; 74: 2152\u20138. doi: 10.1016\/S0006-3495(98)77924-X","DOI":"10.1016\/S0006-3495(98)77924-X"},{"key":"2026071211290142246_j_raon-2024-0047_ref_025","doi-asserted-by":"crossref","unstructured":"Ivorra A, Rubinsky B. Electric field modulation in tissue electroporation with electrolytic and non-electrolytic additives. Bioelectrochemistry 2007; 70: 551\u201360. doi: 10.1016\/j.bioelechem.2007.02.001","DOI":"10.1016\/j.bioelechem.2007.02.001"},{"key":"2026071211290142246_j_raon-2024-0047_ref_026","doi-asserted-by":"crossref","unstructured":"Miklav\u010di\u010d D, \u0160emrov D, Mekid H, Mir LM. A validated model of in vivo electric field distribution in tissues for electrochemotherapy and for DNA electrotransfer for gene therapy. Biochim Biophys Acta 2000; 1523: 73\u201383. doi: 10.1016\/S0304-4165(00)00101-X","DOI":"10.1016\/S0304-4165(00)00101-X"},{"key":"2026071211290142246_j_raon-2024-0047_ref_027","doi-asserted-by":"crossref","unstructured":"Boc N, Edhemovic I, Kos B, Music MM, Brecelj E, Trotovsek B, et al. Ultrasonographic changes in the liver tumors as indicators of adequate tumor coverage with electric field for effective electrochemotherapy. Radiol Oncol 2018; 52: 383\u201391. doi: 10.2478\/raon-2018-0041","DOI":"10.2478\/raon-2018-0041"},{"key":"2026071211290142246_j_raon-2024-0047_ref_028","doi-asserted-by":"crossref","unstructured":"Granata V, Fusco R, Setola SV, Palaia R, Albino V, Piccirillo M, et al. Diffusion kurtosis imaging and conventional diffusion weighted imaging to assess electrochemotherapy response in locally advanced pancreatic cancer. Radiol Oncol 2019; 53: 15\u201324. doi: 10.2478\/raon-2019-0004","DOI":"10.2478\/raon-2019-0004"},{"key":"2026071211290142246_j_raon-2024-0047_ref_029","doi-asserted-by":"crossref","unstructured":"Zmuc J, Gasljevic G, Sersa G, Edhemovic I, Boc N, Seliskar A, et al. Large liver blood vessels and bile ducts are not damaged by electrochemotherapy with bleomycin in pigs. Sci Rep 2019; 9: 3649. doi: 10.1038\/s41598-019-40395-y","DOI":"10.1038\/s41598-019-40395-y"},{"key":"2026071211290142246_j_raon-2024-0047_ref_030","doi-asserted-by":"crossref","unstructured":"Paturneau-Jouas M, Parzy E, Vidal G, Carlier PG, Wary C, Vilquin JT, et al. Electrotransfer at MR imaging: tool for optimization of gene transfer protocols-feasibility study in mice. Radiology 2003; 228: 768\u201375. doi: 10.1148\/RADIOL.2283020482","DOI":"10.1148\/radiol.2283020482"},{"key":"2026071211290142246_j_raon-2024-0047_ref_031","doi-asserted-by":"crossref","unstructured":"Kranjc M, Markelc B, Bajd F, \u010cema\u017ear M, Ser\u0161a I, Blagus T, et al. In situ monitoring of electric field distribution in mouse tumor during electroporation. Radiology 2015; 274: 115\u201323. doi: 10.1148\/radiol.14140311","DOI":"10.1148\/radiol.14140311"},{"key":"2026071211290142246_j_raon-2024-0047_ref_032","doi-asserted-by":"crossref","unstructured":"Leroy-Willig A, Bureau MF, Scherman D, Carlier PG. In vivo NMR imaging evaluation of efficiency and toxicity of gene electrotransfer in rat muscle. Gene Ther 2005; 12: 1434\u201343. doi: 10.1038\/sj.gt.3302541","DOI":"10.1038\/sj.gt.3302541"},{"key":"2026071211290142246_j_raon-2024-0047_ref_033","doi-asserted-by":"crossref","unstructured":"Scott LJ. Gadobutrol: a review in contrast-enhanced MRI and MRA. Clin Drug Investig 2018; 38: 773\u201384. doi: 10.1007\/s40261-018-0674-9","DOI":"10.1007\/s40261-018-0674-9"},{"key":"2026071211290142246_j_raon-2024-0047_ref_034","doi-asserted-by":"crossref","unstructured":"\u010corovi\u0107 S, \u017dupani\u010d A, Kranjc S, Al Sakere B, Leroy-Willig A, Mir LM, et al. The influence of skeletal muscle anisotropy on electroporation: in vivo study and numerical modeling. Med Biol Eng Comput 2010; 48: 637\u201348. doi: 10.1007\/s11517-010-0614-1","DOI":"10.1007\/s11517-010-0614-1"},{"key":"2026071211290142246_j_raon-2024-0047_ref_035","doi-asserted-by":"crossref","unstructured":"Peng W, Polaj\u017eer T, Yao C, Miklav\u010di\u010d D. Dynamics of cell death due to electroporation using different pulse parameters as revealed by different vi-ability assays. Ann Biomed Eng 2024; 52: 22\u201335. doi: 10.1007\/s10439-023-03309-8","DOI":"10.1007\/s10439-023-03309-8"},{"key":"2026071211290142246_j_raon-2024-0047_ref_036","doi-asserted-by":"crossref","unstructured":"Kandu\u0161er M, \u0160entjurc M, Miklav\u010di\u010d D. Cell membrane fluidity related to electroporation and resealing. Eur Biophys J 2006; 35: 196\u2013204. doi: 10.1007\/s00249-005-0021-y","DOI":"10.1007\/s00249-005-0021-y"},{"key":"2026071211290142246_j_raon-2024-0047_ref_037","doi-asserted-by":"crossref","unstructured":"Neu WK, Neu JC. Mechanism of irreversible electroporation in cells: Insight from the models. In: Rubinsky B, editor. Irreversible electroporation. Series in biomedical engineering. Berlin, Heidelberg: Springer; 2010. p. 85\u2013122.","DOI":"10.1007\/978-3-642-05420-4_4"},{"key":"2026071211290142246_j_raon-2024-0047_ref_038","doi-asserted-by":"crossref","unstructured":"Avazzadeh S, O\u2019Brien B, Coffey K, O\u2019Halloran M, Keane D, Quinlan LR. Establishing irreversible electroporation electric field potential threshold in a suspension in vitro model for cardiac and neuronal cells. J Clin Med 2021; 10: 5443. doi: 10.3390\/jcm10225443","DOI":"10.3390\/jcm10225443"},{"key":"2026071211290142246_j_raon-2024-0047_ref_039","doi-asserted-by":"crossref","unstructured":"Saulis G. Pore disappearance in a cell after electroporation: theoretical simulation and comparison with experiments. Biophys J 1997; 73: 1299\u2013309. doi: 10.1016\/S0006-3495(97)78163-3","DOI":"10.1016\/S0006-3495(97)78163-3"},{"key":"2026071211290142246_j_raon-2024-0047_ref_040","doi-asserted-by":"crossref","unstructured":"S\u00f6zer EB, Pocetti CF, Vernier PT. Transport of charged small molecules after electropermeabilization \u2014 drift and diffusion. BMC Biophys 2018; 11: 4. doi: 10.1186\/s13628-018-0044-2","DOI":"10.1186\/s13628-018-0044-2"},{"key":"2026071211290142246_j_raon-2024-0047_ref_041","doi-asserted-by":"crossref","unstructured":"Polaj\u017eer T, Miklav\u010di\u010d D. Immunogenic cell death in electroporation-based therapies depends on pulse waveform characteristics. Vaccines 2023; 11: 1036. doi: 10.3390\/vaccines11061036","DOI":"10.3390\/vaccines11061036"},{"key":"2026071211290142246_j_raon-2024-0047_ref_042","doi-asserted-by":"crossref","unstructured":"Kranjc M, Kranjc S, Bajd F, Ser\u0161a G, Ser\u0161a I, Miklav\u010di\u010d D. Predicting irreversible electroporation-induced tissue damage by means of magnetic resonance electrical impedance tomography. Sci Rep 2017; 7: 10323. doi: 10.1038\/s41598-017-10846-5","DOI":"10.1038\/s41598-017-10846-5"},{"key":"2026071211290142246_j_raon-2024-0047_ref_043","doi-asserted-by":"crossref","unstructured":"Kos B, Voigt P, Miklavcic D, Moche M. Careful treatment planning enables safe ablation of liver tumors adjacent to major blood vessels by percutaneous irreversible electroporation (IRE). Radiol Oncol 2015; 49: 234\u201341. doi: 10.1515\/raon-2015-0031","DOI":"10.1515\/raon-2015-0031"},{"key":"2026071211290142246_j_raon-2024-0047_ref_044","doi-asserted-by":"crossref","unstructured":"Pavliha D, Kos B, Mar\u010dan M, \u017dupani\u010d A, Ser\u0161a G, Miklav\u010di\u010d D. Planning of electroporation-based treatments using web-based treatment-planning software. J Membr Biol 2013; 246: 833\u201342. doi: 10.1007\/s00232-013-9567-2","DOI":"10.1007\/s00232-013-9567-2"},{"key":"2026071211290142246_j_raon-2024-0047_ref_045","doi-asserted-by":"crossref","unstructured":"Crich SG, Biancone L, Cantaluppi V, Du\u00f2 D, Esposito G, Russo S, et al. Improved route for the visualization of stem cells labeled with a Gd-\/Eu-Chelate as dual (MRI and fluorescence) agent. Magn Reson Med 2004; 51: 938\u201344. doi: 10.1002\/mrm.20072","DOI":"10.1002\/mrm.20072"}],"container-title":["Radiology and Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/reference-global.com\/pdf\/10.2478\/raon-2024-0047","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,12]],"date-time":"2026-07-12T23:39:38Z","timestamp":1783899578000},"score":1,"resource":{"primary":{"URL":"https:\/\/reference-global.com\/article\/10.2478\/raon-2024-0047"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,1]]},"references-count":45,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,9,15]]},"published-print":{"date-parts":[[2024,9,1]]}},"alternative-id":["10.2478\/raon-2024-0047"],"URL":"https:\/\/doi.org\/10.2478\/raon-2024-0047","relation":{},"ISSN":["1581-3207"],"issn-type":[{"value":"1581-3207","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,1]]}}}