{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T06:30:19Z","timestamp":1760596219263},"reference-count":40,"publisher":"Walter de Gruyter GmbH","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2010,1,1]]},"DOI":"10.2478\/v10048-010-0029-z","type":"journal-article","created":{"date-parts":[[2010,12,22]],"date-time":"2010-12-22T02:29:47Z","timestamp":1292984987000},"source":"Crossref","is-referenced-by-count":15,"title":["Non-Intrusive Device for Real-Time Circulatory System Assessment with Advanced Signal Processing Capabilities"],"prefix":"10.2478","volume":"10","author":[{"given":"E.","family":"Pinheiro","sequence":"first","affiliation":[]},{"given":"O.","family":"Postolache","sequence":"additional","affiliation":[]},{"given":"P.","family":"Gir\u00e3o","sequence":"additional","affiliation":[]}],"member":"374","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. (1996). Heart rate variability - standards of measurement, physiological interpretation, and clinical use. <i>Circulation<\/i>, 93 (5), 1043-1065.","DOI":"10.1161\/01.CIR.93.5.1043"},{"key":"2","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1161\/01.HYP.25.6.1276","article-title":"Spectral analysis of blood pressure and heart rate variability in evaluating cardiovascular regulation: a critical appraisal","volume":"25","author":"G. Parati","year":"1995","journal-title":"Hypertension"},{"issue":"1","key":"3","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1111\/j.1469-8986.1994.tb01024.x","article-title":"Autonomic space and psychophysiological response","volume":"31","author":"G. Berntson","year":"1994","journal-title":"Psychophysiology"},{"key":"4","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1161\/01.STR.31.2.463","article-title":"Which parameters of beat-to-beat blood pressure and variability best predict early outcome after acute ischemic stroke?","volume":"31","author":"S. Dawson","year":"2000","journal-title":"Stroke"},{"key":"5","doi-asserted-by":"crossref","unstructured":"American College of Cardiology Cardiovascular Technology Assessment Committee. (1993). Heart rate variability for risk stratification of life-threatening arrhythmias. <i>J. Am. Coll. Cardiology<\/i>, 22, 948-950.","DOI":"10.1016\/0735-1097(93)90217-O"},{"key":"6","first-page":"876","article-title":"New approach on cardiac autonomic control estimation based on BCG processing","author":"O. Postolache","year":"2007"},{"key":"7","first-page":"1","article-title":"New device for assessment of autonomous nervous system functioning in psychophysiology","author":"O. Postolache","year":"2007"},{"key":"8","first-page":"79","article-title":"Heart rate variability virtual sensor application in blood pressure assessment system","author":"E. Pinheiro","year":"2008"},{"key":"9","first-page":"378","article-title":"Wearable body sensor network for continuous context-related pulse arrival time monitoring","author":"J. Muehslteff","year":"2008"},{"key":"10","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1007\/BF02442787","article-title":"Pulse arrival time as a method of obtaining systolic and diastolic blood pressure indirectly","volume":"19","author":"L. Geddes","year":"1981","journal-title":"Med. Biol. Eng. Comput"},{"key":"11","first-page":"996","article-title":"A correlation study on the variabilities in pulse transit time, blood pressure, and heart rate recorded simultaneously from healthy subjects","author":"T. Ma","year":"2005"},{"issue":"5","key":"12","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1007\/BF02345755","article-title":"Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration","volume":"38","author":"W. Chen","year":"2000","journal-title":"Med. Biol. Eng. Comput"},{"key":"13","first-page":"222","article-title":"Comparison of the relationship between blood pressure and pulse wave transit times at different sites","author":"Y. Sugo","year":"1999"},{"issue":"5","key":"14","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1111\/j.1469-8986.1976.tb00866.x","article-title":"Pulse wave velocity and blood pressure change: calibration and applications","volume":"13","author":"A. Steptoe","year":"1976","journal-title":"Psychophysiology"},{"issue":"1","key":"15","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1111\/j.1469-8986.1976.tb03344.x","article-title":"Pulse wave velocity as a measure of blood pressure change","volume":"13","author":"B. Gribbin","year":"1976","journal-title":"Psychophysiology"},{"key":"16","first-page":"11","article-title":"Wireless body sensor network for continuous cuff-less blood pressure monitoring","author":"J. Espina","year":"2006"},{"key":"17","first-page":"132","article-title":"Pulse arrival time and ballistocardiogram application to blood pressure variability estimation","author":"E. Pinheiro","year":"2009"},{"key":"18","first-page":"1308","article-title":"A hydrostatic calibration method for the design of wearable PAT-based blood pressure monitoring devices","author":"Y. Kiu","year":"2008"},{"issue":"2","key":"19","doi-asserted-by":"crossref","first-page":"549","DOI":"10.2147\/TCRM.S2521","article-title":"Nonlinear analysis of the heartbeats in public patient ECGs using an automated PD2i algorithm for risk stratification of arrhythmic death","volume":"4","author":"J. Skinner","year":"2008","journal-title":"Ther. Clin. Risk Manag"},{"issue":"6","key":"20","first-page":"2429","article-title":"Fractal dimension of heart rate time series: an effective measure of autonomic function","volume":"75","author":"V. Yeragani","year":"1993","journal-title":"J. Appl. Phys"},{"issue":"3","key":"21","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/0002-8703(93)90165-6","article-title":"A reduction in the correlation dimension of heartbeat intervals precedes imminent ventricular fibrillation in human subjects","volume":"125","author":"J. Skinner","year":"1993","journal-title":"Am. Heart J"},{"key":"22","first-page":"257","volume-title":"Computers in Cardiology","author":"T. Vybiral","year":"1993"},{"issue":"4","key":"23","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1007\/BF02688699","article-title":"Approximate entropy and point correlation dimension of heart rate variability in healthy subjects","volume":"33","author":"R. Storella","year":"1998","journal-title":"Integr. Physiol. Behav. Sci"},{"issue":"3","key":"24","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1042\/CS19970268","article-title":"Fractal dimension and approximate entropy of heart period and heart rate: awake versus sleep differences and methodological issues","volume":"95","author":"V. Yeragani","year":"1998","journal-title":"Clin. Sci"},{"issue":"2-3","key":"25","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1081\/CEH-48742","article-title":"Fractal and complexity measures of heart rate variability","volume":"27","author":"J. Perki\u00f6m\u00e4ki","year":"2005","journal-title":"Clin. Exp. Hypertens"},{"issue":"6","key":"26","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1152\/ajpheart.2000.278.6.H2039","article-title":"Physiological time-series analysis using approximate entropy and sample entropy","volume":"278","author":"J. Richman","year":"2000","journal-title":"Am. J. Physiol. Heart Circ. Physiol"},{"issue":"2","key":"27","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.jneumeth.2005.10.009","article-title":"EEG analysis using wavelet-based information tools","volume":"153","author":"O. Rosso","year":"2006","journal-title":"J. Neurosci. Methods"},{"key":"28","unstructured":"Lunak, D. R., Bryngelson, R. S. (2006). <i>Noninvasive Blood Pressure Monitor Having Automatic High Motion Tolerance.<\/i> U. S. Patent No. 7,052,465. Washington, D. C.: U. S. Patent and Trademark Office."},{"issue":"2","key":"29","doi-asserted-by":"crossref","first-page":"97","DOI":"10.3233\/THC-2006-14205","article-title":"Pulse transit time as an indirect marker for variations in cardiovascular related reactivity","volume":"14","author":"J. Foo","year":"2006","journal-title":"Technol. Health Care"},{"key":"30","first-page":"5088","article-title":"Cuffless estimation of systolic blood pressure for short effort bicycle tests: the prominent role of the pre-ejection period","author":"J. Muehlsteff","year":"2006"},{"key":"31","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1152\/japplphysiol.00657.2005","article-title":"Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure","volume":"100","author":"R. Payne","year":"2006","journal-title":"J. Appl. Physiol"},{"key":"32","doi-asserted-by":"crossref","first-page":"201","DOI":"10.2174\/1874120701004010201","article-title":"Theory and developments in an unobtrusive cardiovascular system representation: Ballistocardiography","volume":"4","author":"E. Pinheiro","year":"2010","journal-title":"Open Biomed. Engin. J"},{"key":"33","volume-title":"Fractals, Chaos, Power Laws: Minutes from an Infinite Paradise","author":"M. Schroeder","year":"1991"},{"issue":"6","key":"34","doi-asserted-by":"crossref","first-page":"021906","DOI":"10.1103\/PhysRevLett.89.068102","article-title":"Multiscale entropy analysis of complex physiologic time series","volume":"89","author":"M. Costa","year":"2002","journal-title":"Phys. Rev. Lett"},{"key":"35","doi-asserted-by":"crossref","first-page":"2297","DOI":"10.1073\/pnas.88.6.2297","article-title":"Approximate entropy as a measure of system complexity","volume":"88","author":"S. Pincus","year":"1991","journal-title":"Proc. Natl. Acad. Sci. USA"},{"issue":"6","key":"36","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1152\/ajpheart.2000.278.6.H2039","article-title":"Physiological time-series analysis using approximate entropy and sample entropy","volume":"278","author":"J. Richman","year":"2000","journal-title":"Am. J. Physiol. Heart Circ. Physiol"},{"issue":"1","key":"37","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/S0197-4580(01)00266-4","article-title":"What is physiologic complexity and how does it change with aging and disease?","volume":"23","author":"A. Goldberger","year":"2002","journal-title":"Neurobiol. Aging"},{"key":"38","first-page":"743","article-title":"EMFi - new electret material for sensors and actuators","author":"J. Lekkala","year":"1999"},{"key":"39","volume-title":"Biophysical Measurements","author":"P. Strong","year":"1970"},{"key":"40","first-page":"602","article-title":"Automatic wavelet detrending benefits to the analysis of cardiac signals acquired in a moving wheelchair","author":"E. Pinheiro","year":"2010"}],"container-title":["Measurement Science Review"],"original-title":[],"link":[{"URL":"https:\/\/www.degruyter.com\/view\/j\/msr.2010.10.issue-5\/v10048-010-0029-z\/v10048-010-0029-z.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,14]],"date-time":"2020-06-14T22:24:06Z","timestamp":1592173446000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/doi\/10.2478\/v10048-010-0029-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1,1]]},"references-count":40,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.2478\/v10048-010-0029-z","relation":{},"ISSN":["1335-8871"],"issn-type":[{"value":"1335-8871","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1,1]]}}}