{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T23:06:31Z","timestamp":1768518391767,"version":"3.49.0"},"reference-count":23,"publisher":"National Institute of Industrial Health","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ind Health"],"published-print":{"date-parts":[[2012]]},"DOI":"10.2486\/indhealth.ms1326","type":"journal-article","created":{"date-parts":[[2012,2,1]],"date-time":"2012-02-01T00:55:08Z","timestamp":1328057708000},"page":"103-114","source":"Crossref","is-referenced-by-count":8,"title":["Flow and Containment Characteristics of an Air-curtain Fume Hood Operated at High Temperatures"],"prefix":"10.2486","volume":"50","author":[{"given":"Jia-Kun","family":"CHEN","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong Fung","family":"HUANG","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pei-Yi","family":"HSIN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ching Min","family":"HSU","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chun-Wann","family":"CHEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1332","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1080\/15459620802399989"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1202\/1542-8125(2003)64<251:LCHAHP>2.0.CO;2"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1202\/0002-8894(1989)050<0275:ANMFQI>2.0.CO;2"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1093\/annhyg\/36.3.239"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1093\/annhyg\/36.4.395"},{"key":"6","unstructured":"6) Saunders T (1993) Laboratory Fume Hoods: A User&rsquo;s Manual, 56&ndash;81, John Wiley &amp; Sons, New York."},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Volin CE, Joao RV, Reiman JS, Party E, Gershey EL (1998) Fume hood performance: face velocity variability inconsistent air volume systems. Appl Occup Environ Hyg 13, 656&ndash;62.","DOI":"10.1080\/1047322X.1998.10390134"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1080\/15428119891010398"},{"key":"9","unstructured":"9) Ekberg LE, Melin J (2000) Required response time for variable air volume fume hood controller. Ann Occup Hyg 44, 143&ndash;50."},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4878(94)00112-E"},{"key":"11","unstructured":"11) Guffey SE, Flanagan ME, van Belle G (2001) Air sampling at the chest and ear as representative of the breathing zone. Am Ind Hyg Assoc J 62, 416&ndash;27."},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1080\/15459620601015695"},{"key":"13","unstructured":"13) Tseng LC, Huang RF, Chen CC, Chang CP (2007) Aerodynamics and performance verifications of test methods for laboratory fume cupboards. Ann Occup Hyg 51, 173&ndash;87."},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Bennett JS, Crouch KG, Shulman SA (2003) Control of wake-induced exposure using an interrupted oscillating jet. Am Ind Hyg Assoc J 64, 24&ndash;9.","DOI":"10.1080\/15428110308984779"},{"key":"15","unstructured":"15) Ekberg LE, Melin J (2000) Required response time for variable air volume fume hood controllers. Ann Occup Hyg 44, 143&ndash;50."},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1093\/annhyg\/mel051"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.2486\/indhealth.45.804"},{"key":"18","unstructured":"18) Huang RF, Lin SY, Jan SY, Hsieh RH, Chen YK, Chen CW, The WY, Chang CP, Shih TS, Chen CC (2005) Aerodynamic characteristics and design guidelines of push-pull ventilation systems. Ann Occup Hyg 49, 1&ndash;15."},{"key":"19","unstructured":"19) European Committee for Standardization (2003) EN: 14175-3: 2003 Fume cupboards-Parts 3: type test methods. European Committee for Standardization, Brussels."},{"key":"20","unstructured":"20) American Society of Heating, Refrigeration and Air Conditioning Engineers Inc (1995) ANSI\/ASHRAE Standard 110&ndash;1995: Method of testing performance of laboratory fume hoods. American Society of Heating, Refrigeration and Air Conditioning Engineers Inc. Atlanta."},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1093\/annhyg\/mep074"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1007\/s11051-008-9459-z"},{"key":"23","unstructured":"23) Flagan RC, Seinfeld JH (1988) Fundamentals of Air Pollution Engineering, 290&ndash;357, Prentice Hall, Englewood Cliffs, New Jersey."}],"container-title":["Industrial Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/indhealth\/50\/2\/50_MS1326\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,22]],"date-time":"2019-06-22T23:38:14Z","timestamp":1561246694000},"score":1,"resource":{"primary":{"URL":"http:\/\/joi.jlc.jst.go.jp\/JST.JSTAGE\/indhealth\/MS1326?from=CrossRef"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.2486\/indhealth.ms1326","relation":{},"ISSN":["0019-8366","1880-8026"],"issn-type":[{"value":"0019-8366","type":"print"},{"value":"1880-8026","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012]]}}}