{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T00:19:10Z","timestamp":1726273150647},"reference-count":49,"publisher":"Oceanside Publications Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["allergy asthma proc"],"published-print":{"date-parts":[[2024,5,1]]},"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Concern of metal sensitization in pre- and postsurgical evaluation is growing, with the recent guidelines remaining the criterion standard for consideration of patch testing. Information remains scarce on surgical screening in the groups of patients who reported\n a history of metal sensitivity versus those with no reported history.  <jats:bold>Objective:<\/jats:bold> The objective of this study was to assess the utility of patch testing in surgical candidates based on reported metal allergy history. The secondary objective was to evaluate the utility and\n outcomes in postsurgical patch testing.  <jats:bold>Methods:<\/jats:bold> Nine hundred and thirty-one patient charts of patients with the diagnosis of \u201ccontact dermatitis\u201d who underwent an evaluation at a single allergy clinic site between January 2013 and December 2022 were identified\n and reviewed as part of a retrospective chart review study. Patients were included in subgroups based on the time of patch testing and history of reported metal allergy.  <jats:bold>Results:<\/jats:bold> In all, 67 patients underwent patch testing, 10 (14.9%) of whom were surgical candidates without\n a history of metal sensitivity, 31 (46.2%) of whom were surgical candidates with a history of metal sensitivity, and 26 (38.8%) of whom were postsurgical patients. Twenty-nine (43.3%) of patients had positive patch testing results, with only one (10%) in the presurgical group, 17 (54.8%) in\n the presurgical with a history of metal sensitivity, and 11 (42.3%) in the postsurgical group. Zero patients in our cohort without metal sensitivity who were undergoing the Nuss procedure had positive reactions on patch testing, whereas two of four (50%) with reported metal sensitivity who\n were undergoing the Nuss procedure had positive relevant metal reactions.  <jats:bold>Conclusion:<\/jats:bold> Ambiguity in the utility of patch testing for surgical decision making remains, despite common utilization. Recent guidelines along with coordination of care among the surgeon, allergist,\n and patient remains the criterion standard of care.<\/jats:p>","DOI":"10.2500\/aap.2024.45.240005","type":"journal-article","created":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T04:50:02Z","timestamp":1715921402000},"page":"186-194","source":"Crossref","is-referenced-by-count":1,"title":["Metal implant allergy: A retrospective cohort analysis at a university allergy practice"],"prefix":"10.2500","volume":"45","author":[{"given":"Mark J.","family":"Taliercio","sequence":"first","affiliation":[{"name":"From the Department of Internal Medicine, Albany Medical Center, Albany, New York"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rawaa K.","family":"Alnabulsi","sequence":"additional","affiliation":[{"name":"Division of Allergy and Immunology, Department of Internal Medicine, Albany Medical Center, Albany, New York"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Priya A.","family":"Uppal","sequence":"additional","affiliation":[{"name":"Albany Medical College, Albany, New York"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ian M.","family":"Shaw","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Albany Medical Collage, Albany, New York, and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kristy M.","family":"Semenza","sequence":"additional","affiliation":[{"name":"Department of Allergy and Immunology, Bassett Medical Center, Cooperstown, New York"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muhammad A.","family":"Pasha","sequence":"additional","affiliation":[{"name":"Division of Allergy and Immunology, Department of Internal Medicine, Albany Medical Center, Albany, New York"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1355","reference":[{"key":"B1","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/S0022-3913(08)60233-4","article-title":"Suspected association of an allergic reaction with titanium dental implants: a clinical report","volume":"100","author":"Egusa","year":"2008","journal-title":"J Prosthet Dent"},{"key":"B2","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1111\/j.1468-3083.2004.01014.x","article-title":"Nickel allergy and orthodontic treatment","volume":"18","author":"Kalimo","year":"2004","journal-title":"J Eur Acad Dermatol Venereol"},{"key":"B3","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s00264-013-2229-2","article-title":"Total knee arthroplasty in patients with hypersensitivity to metals","volume":"38","author":"Innocenti","year":"2014","journal-title":"Int Orthop"},{"key":"B4","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1302\/0301-620X.98B4.36767","article-title":"Allergy in total knee arthroplasty: a review of the facts","volume":"98-B","author":"Middleton","year":"2016","journal-title":"Bone Joint J"},{"key":"B5","first-page":"332","article-title":"Outcomes of revision joint arthroplasty due to metal allergy and hypersensitivity: a systematic review","volume":"33","author":"Jauregui","year":"2018","journal-title":"Surg Technol Int"},{"key":"B6","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s00132-007-1186-0","article-title":"Metal sensitivity in patients with joint replacement arthroplasties before and after surgery","volume":"37","author":"Rau","year":"2008","journal-title":"Orthopade"},{"key":"B7","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1007\/s00105-007-1453-3","article-title":"Orthopedic surgical implants and allergies: joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)","volume":"59","author":"Thomas","year":"2008","journal-title":"Hautarzt"},{"key":"B8","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1186\/s40792-020-00843-8","article-title":"Metallic allergy requiring removal of iliac stent: report of a case","volume":"6","author":"Guntani","year":"2020","journal-title":"Surg Case Rep"},{"key":"B9","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.carrev.2016.12.020","article-title":"Bioresorbable vascular scaffold to treat malignant in-stent restenosis in a patient with nickel allergy","volume":"18","author":"Jurado-Rom\u00e1n","year":"2017","journal-title":"Cardiovasc Revasc Med"},{"key":"B10","doi-asserted-by":"crossref","first-page":"19.091","DOI":"10.7812\/TPP\/19.091","article-title":"Incidence of metal hypersensitivity in orthopedic surgical patients who self-report hypersensitivity history","volume":"24","author":"Schultzel","year":"2020","journal-title":"Perm J"},{"key":"B11","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1111\/cod.13637","article-title":"Clinical factors before or after device implantation in predicting metal hypersensitivity reactions: a retrospective study","volume":"83","author":"Tam","year":"2020","journal-title":"Contact Dermatitis"},{"key":"B12","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1111\/cod.13032","article-title":"Metal hypersensitivity in patients with orthopaedic implant complications\u2013a retrospective clinical study","volume":"79","author":"Furrer","year":"2018","journal-title":"Contact Dermatitis"},{"key":"B13","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/S0190-9622(98)70587-0","article-title":"North American Contact Dermatitis Group patch test results for the detection of delayed-type hypersensitivity to topical allergens","volume":"38","author":"Marks","year":"1998","journal-title":"J Am Acad Dermatol"},{"key":"B14","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.jaad.2005.04.077","article-title":"Patch test results from the Mayo Clinic Contact Dermatitis Group, 1998-2000","volume":"53","author":"Wetter","year":"2005","journal-title":"J Am Acad Dermatol"},{"key":"B15","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.jaad.2008.04.022","article-title":"Delayed patch test reading after 5 days: the Mayo Clinic experience","volume":"59","author":"Davis","year":"2008","journal-title":"J Am Acad Dermatol"},{"key":"B16","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.jaip.2015.02.009","article-title":"Contact dermatitis: a practice parameter\u2013update 2015","volume":"3","author":"Fonacier","year":"2015","journal-title":"J Allergy Clin Immunol Pract"},{"key":"B17","first-page":"708","article-title":"The International Contact Dermatitis Research Group","volume":"18","author":"Calnan","year":"1976","journal-title":"Cutis"},{"key":"B18","first-page":"473","article-title":"Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery","volume":"164","author":"Thyssen","year":"2011","journal-title":"Br J Dermatol"},{"key":"B19","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.jaip.2018.05.018","article-title":"Determining the clinical relevance of positive patch testing to gold in evaluation of contact dermatitis","volume":"7","author":"Yang","year":"2019","journal-title":"J Allergy Clin Immunol Pract"},{"key":"B20","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1097\/DER.0000000000000210","article-title":"Patch testing for evaluation of hypersensitivity to implanted metal devices: a perspective from the American Contact Dermatitis Society","volume":"27","author":"Schalock","year":"2016","journal-title":"Dermatitis"},{"key":"B21","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1111\/j.1600-0536.2011.01970.x","article-title":"Metal allergy and second-generation metal-on-metal arthroplasties","volume":"66","author":"Cousen","year":"2012","journal-title":"Contact Dermatitis"},{"key":"B22","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1111\/j.1600-0536.1976.tb03044.x","article-title":"The development of metal hypersensitivity in patients with metal-to-plastic hip arthroplasties","volume":"2","author":"Nater","year":"1976","journal-title":"Contact Dermatitis"},{"key":"B23","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1111\/j.1600-0536.1985.tb02581.x","article-title":"Allergy in hip arthroplasty","volume":"13","author":"Waterman","year":"1985","journal-title":"Contact Dermatitis"},{"key":"B24","first-page":"1515","article-title":"Early osteolysis following second-generation metal-on-metal hip replacement","volume":"87","author":"Park","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"B25","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1034\/j.1600-0536.2003.480108_4.x","article-title":"Metal allergy resurfaces in failed hip endoprostheses","volume":"48","author":"Antony","year":"2003","journal-title":"Contact Dermatitis"},{"key":"B26","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1001\/archderm.144.8.999","article-title":"Retrospective evaluation of patch testing before or after metal device implantation","volume":"144","author":"Reed","year":"2008","journal-title":"Arch Dermatol"},{"key":"B27","doi-asserted-by":"crossref","first-page":"1494","DOI":"10.1016\/j.biomaterials.2007.11.038","article-title":"Sensitivity to implant materials in patients with total knee arthroplasties","volume":"29","author":"Granchi","year":"2008","journal-title":"Biomaterials"},{"key":"B28","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/DER.0000000000000341","article-title":"Patch testing for the evaluation of metal hypersensitivity in the Nuss procedure","volume":"29","author":"Selvick","year":"2018","journal-title":"Dermatitis"},{"key":"B29","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1600-0536.2011.01971.x","article-title":"Hypersensitivity reactions to metallic implants - diagnostic algorithm and suggested patch test series for clinical use","volume":"66","author":"Schalock","year":"2012","journal-title":"Contact Dermatitis"},{"key":"B30","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1111\/j.1600-0536.2011.01966.x","article-title":"Dermatitis in patients undergoing the Nuss procedure for correction of pectus excavatum","volume":"65","author":"Aneja","year":"2011","journal-title":"Contact Dermatitis"},{"key":"B31","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/DER.0000000000000149","article-title":"Patch testing for metal allergy with manufacturer-supplied materials before Nuss bar insertion","volume":"26","author":"Heitmiller","year":"2015","journal-title":"Dermatitis"},{"key":"B32","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1055\/a-1868-6224","article-title":"Preoperative metal patch testing and titanium bar use criteria in Nuss procedure: a 56-patients' cohort study","volume":"33","author":"Pereira-Nunes","year":"2023","journal-title":"Eur J Pediatr Surg"},{"key":"B33","doi-asserted-by":"crossref","first-page":"3109","DOI":"10.1016\/j.jaip.2020.12.068","article-title":"Sensitization to implant components is associated with joint replacement failure: identification and revision to nonallergenic hardware improves outcomes","volume":"9","author":"Mayer","year":"2021","journal-title":"J Allergy Clin Immunol Pract"},{"key":"B34","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1016\/j.anai.2021.02.018","article-title":"The role of metal patch testing in evaluating patients for metallic prosthetic joint failure","volume":"126","author":"Keller","year":"2021","journal-title":"Ann Allergy Asthma Immunol"},{"key":"B35","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1136\/heartjnl-2021-319940","article-title":"Nickel hypersensitivity and endovascular devices: a systematic review and meta-analysis","volume":"108","author":"Gu\u00e9roult","year":"2022","journal-title":"Heart"},{"key":"B36","doi-asserted-by":"crossref","first-page":"330","DOI":"10.3928\/01477447-20190906-01","article-title":"Self-reported metal allergy and early outcomes after total knee arthroplasty","volume":"42","author":"Schmidt","year":"2019","journal-title":"Orthopedics"},{"key":"B37","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1001\/archdermatol.2011.2561","article-title":"The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants","volume":"148","author":"Atanaskova Mesinkovska","year":"2012","journal-title":"Arch Dermatol"},{"key":"B38","first-page":"e023","article-title":"Exploring the incidence, implications, and relevance of metal allergy to orthopaedic surgeons","volume":"3","author":"Haddad","year":"2019","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"B39","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1007\/s12016-018-8707-y","article-title":"Allergy to surgical implants","volume":"56","author":"Pacheco","year":"2019","journal-title":"Clin Rev Allergy Immunol"},{"key":"B40","doi-asserted-by":"crossref","first-page":"256","DOI":"10.2310\/6620.2011.11035","article-title":"Patch testing with a large series of metal allergens: findings from more than 1,000 patients in one decade at Mayo Clinic","volume":"22","author":"Davis","year":"2011","journal-title":"Dermatitis"},{"key":"B41","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1016\/j.arth.2016.01.024","article-title":"No increased risk of knee arthroplasty failure in patients with positive skin patch testing for metal hypersensitivity: a matched cohort study","volume":"31","author":"Bravo","year":"2016","journal-title":"J Arthroplasty"},{"key":"B42","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.jpor.2015.12.004","article-title":"Allergic contact dermatitis caused by titanium screws and dental implants","volume":"60","author":"Hosoki","year":"2016","journal-title":"J Prosthodont Res"},{"key":"B43","doi-asserted-by":"crossref","first-page":"722.e1","DOI":"10.1016\/j.ajodo.2008.01.013","article-title":"Prevalence of nickel hypersensitivity in orthodontic patients: a meta-analysis","volume":"134","author":"Kolokitha","year":"2008","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"B44","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1007\/s00132-015-3150-8","article-title":"Should metal alloy discs be used for patch testing in suspected metal implant intolerance reaction?","volume":"44","author":"Thomas","year":"2015","journal-title":"Orthopade"},{"key":"B45","first-page":"e5761","article-title":"Utility of patch testing and lymphocyte transformation testing in the evaluation of metal allergy in patients with orthopedic implants","volume":"11","author":"Richards","year":"2019","journal-title":"Cureus"},{"key":"B46","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1186\/s13018-019-1228-4","article-title":"Improved outcomes in patients with positive metal sensitivity following revision total knee arthroplasty","volume":"14","author":"Zondervan","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"B47","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1111\/cod.12751","article-title":"Evaluation of lymphocyte transformation tests as compared with patch tests in nickel allergy diagnosis","volume":"76","author":"St\u00e4nder","year":"2017","journal-title":"Contact Dermatitis"},{"key":"B48","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1016\/j.jaci.2013.03.023","article-title":"Development of a validated blood test for nickel sensitization","volume":"132","author":"Pacheco","year":"2013","journal-title":"J Allergy Clin Immunol"},{"key":"B49","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1111\/j.1600-0536.2011.01886.x","article-title":"Metal sensitivity in patients with orthopaedic implants: a prospective study","volume":"64","author":"Frigerio","year":"2011","journal-title":"Contact Dermatitis"}],"container-title":["Allergy and Asthma Proceedings"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ingentaconnect.com\/content\/ocean\/aap\/2024\/00000045\/00000003\/art00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T04:34:51Z","timestamp":1726202091000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ingentaconnect.com\/content\/10.2500\/aap.2024.45.240005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,1]]},"references-count":49,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,5,1]]}},"alternative-id":["1088-5412(20240501)45:3L.186;1-"],"URL":"https:\/\/doi.org\/10.2500\/aap.2024.45.240005","relation":{},"ISSN":["1088-5412"],"issn-type":[{"type":"print","value":"1088-5412"}],"subject":[],"published":{"date-parts":[[2024,5,1]]}}}