{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:55:02Z","timestamp":1787025302073,"version":"build-2736575974"},"reference-count":28,"publisher":"Scientific Scholar","content-domain":{"domain":["ijmr.org.in"],"crossmark-restriction":true},"short-container-title":["Indian J Med Res"],"abstract":"<jats:sec>\n                    <jats:title>Background &amp; objectives<\/jats:title>\n                    <jats:p>Timely detection of population with \u03b2-thalassemia trait (BTT) followed by genetic counselling is an advocated method of preventing the birth of a child with \u03b2-thalassemia major. In this study we aim to assess the diagnostic accuracy of Gazelle, a point-of-care (POC) testing device, in screening for BTT in hospital laboratory setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Standards for Reporting Diagnostic Accuracy (STARD) guidelines were followed in developing study design, recruiting study participants and sample size calculation for the current research. A consecutive sample of 446 participants was recruited for this study and was tested for the reference test Gazelle as well as the gold standard cation exchange high performance liquid chromatography (CE-HPLC). Low serum ferritin levels are known to interfere with the production of HbA2 and in turn lead to false negative results. Hence, the study population was divided into two categories with respect to a cut off value of 15ng\/dl of serum ferritin and the results were analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Overall diagnostic accuracy of Gazelle for detecting BTT was found to be 95.3 per cent with a confidence interval (CI) of (92.9 - 97.1) and the sensitivity was 94.5 per cent with a 95% CI of (84.8 - 98.8). When analyzed by the serum ferritin level the diagnostic accuracy was found to be 94.7 per cent (91.1% - 97.1%) and 95.7 per cent (91.8% - 98.1%) for participants with serum ferritin level as &gt; 15 ng\/ml and &lt; 15 ng\/ml, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interpretation &amp; conclusions<\/jats:title>\n                    <jats:p>This study found Gazelle to be a good screening tool for \u03b2-thalassemia trait with high sensitivity, specificity and accuracy. However, it is recommended that the final confirmation of the diagnosis done by a diagnostic test like HPLC or Capillary Zone Electrophoresis (CZE).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/ijmr_1986_23","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T12:47:55Z","timestamp":1729687675000},"page":"194-200","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Assessment of diagnostic accuracy of Gazelle: A point-of-care testing device for screening \u03b2-thalassemia trait"],"prefix":"10.25259","volume":"160","author":[{"given":"Neha","family":"Singh","sequence":"first","affiliation":[{"name":"Centre for Community Medicine, All India Institute of Medical Science, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tulika","family":"Seth","sequence":"additional","affiliation":[{"name":"Department of Haematology, All India Institute of Medical Science, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasmita","family":"Dass","sequence":"additional","affiliation":[{"name":"Department of Haematology, All India Institute of Medical Science, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2024,10,22]]},"reference":[{"key":"10.25259\/ijmr_1986_23\/ref-1","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/S0140-6736(17)31822-6","article-title":"Thalassaemia","volume":"391","author":"Taher","year":"2018","journal-title":"Lancet"},{"key":"10.25259\/ijmr_1986_23\/ref-2","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1056\/NEJMra050436","article-title":"\u03b2-thalassemia","volume":"353","author":"Rund","year":"2005","journal-title":"N Engl J Med"},{"key":"10.25259\/ijmr_1986_23\/ref-3","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1056\/NEJMra2021838","article-title":"\u03b2-thalassemia","volume":"384","author":"Taher","year":"2021","journal-title":"N Engl J Med"},{"key":"10.25259\/ijmr_1986_23\/ref-4","doi-asserted-by":"crossref","first-page":"480","DOI":"10.2471\/BLT.06.036673","article-title":"Global epidemiology of haemoglobin disorders and derived service indicators","volume":"86","author":"Modell","year":"2008","journal-title":"Bull World Health Organ"},{"key":"10.25259\/ijmr_1986_23\/ref-5","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1177\/014107680109401119","article-title":"Disorders of haemoglobin: Genetics, pathophysiology and clinical management","volume":"94","author":"Somervaille","year":"2001","journal-title":"J R Soc Med"},{"key":"10.25259\/ijmr_1986_23\/ref-6","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1111\/ejh.13512","article-title":"Changing patterns in the epidemiology of \u03b2\u2010thalassemia","volume":"105","author":"Kattamis","year":"2020","journal-title":"Eur J Haematol"},{"key":"10.25259\/ijmr_1986_23\/ref-7","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1136\/jmg.18.4.266","article-title":"Effectiveness of one tube osmotic fragility screening in detecting beta-thalassaemia trait","volume":"18","author":"Kattamis","year":"1981","journal-title":"J Med Genet"},{"key":"10.25259\/ijmr_1986_23\/ref-8","first-page":"3519","article-title":"Hemechip: An automated portable microchip electrophoresis platform for point-of-care sickle cell disease screening","volume":"130","author":"Hasan","year":"2017","journal-title":"Blood"},{"key":"10.25259\/ijmr_1986_23\/ref-9","doi-asserted-by":"crossref","first-page":"2525","DOI":"10.1039\/C9AN02250C","article-title":"Paper based microchip electrophoresis for point-of-care haemoglobin testing","volume":"145","author":"Hasan","year":"2020","journal-title":"Analyst"},{"key":"10.25259\/ijmr_1986_23\/ref-10","first-page":"37","article-title":"Integrated point-of-care device for anaemia detection and haemoglobin variant identification","author":"An","year":"2019","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.25259\/ijmr_1986_23\/ref-11","first-page":"826","article-title":"STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies","volume":"277","author":"Bossuyt","year":"2015","journal-title":"Br Med J"},{"key":"10.25259\/ijmr_1986_23\/ref-12","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1111\/j.1553-2712.1996.tb03538.x","article-title":"Statistical methodology: I. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity","volume":"3","author":"Buderer","year":"1996","journal-title":"Acad Emerg Med"},{"key":"10.25259\/ijmr_1986_23\/ref-13","doi-asserted-by":"crossref","first-page":"83","DOI":"10.3390\/bios14020083","article-title":"First point-of-care diagnostic test for beta-thalassemia","volume":"14","author":"An","year":"2022","journal-title":"Biosensors (Basel)"},{"key":"10.25259\/ijmr_1986_23\/ref-14","doi-asserted-by":"crossref","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding bland altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochemia Medica"},{"key":"10.25259\/ijmr_1986_23\/ref-15","first-page":"780","article-title":"Screening for beta-thalassaemia carriers in Egypt: significance of the osmotic fragility test","volume":"13","author":"El-Beshlawy","year":"2007","journal-title":"East Mediterr Health J"},{"key":"10.25259\/ijmr_1986_23\/ref-16","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1258\/0004563021901720","article-title":"Molecular analysis of a thai beta-thalassaemia heterozygote with normal haemoglobin A2 level: Implication for population screening","volume":"39","author":"Fucharoen","year":"2002","journal-title":"Ann Clin Biochem"},{"key":"10.25259\/ijmr_1986_23\/ref-17","first-page":"1538","article-title":"Validation of osmotic fragility test and dichlorophenol indophenol precipitation test for screening of thalassemia and Hb E","volume":"36","author":"Sangkitporn","year":"2005","journal-title":"Southeast Asian J Trop Med Public Health"},{"key":"10.25259\/ijmr_1986_23\/ref-18","first-page":"145","article-title":"Screening for the carriers of thalassemias and abnormal haemoglobins at the community level","volume":"33","author":"Winichagoon","year":"2002","journal-title":"Southeast Asian J Trop Med Public Health"},{"key":"10.25259\/ijmr_1986_23\/ref-19","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1002\/ajh.20387","article-title":"Evaluation of single-tube osmotic fragility as a screening test for thalassemia","volume":"79","author":"Chow","year":"2005","journal-title":"Am J Hematol"},{"key":"10.25259\/ijmr_1986_23\/ref-20","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1159\/000064746","article-title":"A simplified screening for alphathalassemia 1 (SEA type) using a combination of a modified osmotic fragility test and a direct PCR on whole blood cell lysates","volume":"108","author":"Panyasai","year":"2002","journal-title":"Acta Haematol"},{"key":"10.25259\/ijmr_1986_23\/ref-21","doi-asserted-by":"crossref","first-page":"472","DOI":"10.3324\/haematol.2011.052357","article-title":"Iron deficiency does not compromise the diagnosis of high HbA2 \u03b2 thalassemia trait","volume":"97","author":"Passarello","year":"2012","journal-title":"Haematologica"},{"key":"10.25259\/ijmr_1986_23\/ref-22","doi-asserted-by":"crossref","first-page":"858294","DOI":"10.1155\/2013\/858294","article-title":"Haemoglobin A2 lowered by iron deficiency and a-thalassemia: Should screening recommendation for b-thalassemia change?","volume":"2013","author":"Denic","year":"2013","journal-title":"ISRN Hematol"},{"key":"10.25259\/ijmr_1986_23\/ref-23","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1111\/ijlh.12246","article-title":"Impact of iron deficiency on haemoglobin A2% in obligate \u03b2\u2010thalassemia heterozygotes","volume":"37","author":"Sharma","year":"2015","journal-title":"Int J lab Hematol"},{"key":"10.25259\/ijmr_1986_23\/ref-24","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1620\/tjem.223.223","article-title":"Elevated haemoglobin A2 as a marker for \u03b2-thalassemia trait in pregnant women","volume":"223","author":"Ou","year":"2011","journal-title":"Tohoku J Exp Med"},{"key":"10.25259\/ijmr_1986_23\/ref-25","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1111\/ijlh.13035","article-title":"Erythrocyte indices in a large cohort of \u03b2\u2010thalassemia carrier: implication for population screening in an area with high prevalence and heterogeneity of thalassemia","volume":"41","author":"Singha","year":"2019","journal-title":"Int J lab Hematol"},{"key":"10.25259\/ijmr_1986_23\/ref-26","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1163\/156855902320387961","article-title":"Efficiency of premarital screening of beta-thalassemia trait using MCH rather than MCV in the population of Fars Province, Iran","volume":"32","author":"Karimi","year":"2002","journal-title":"Haematologia"},{"key":"10.25259\/ijmr_1986_23\/ref-27","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/01.HS9.0000873108.74233.3d","article-title":"P-054: Evaluation of first microchip-based point-of-care device for diagnosis of beta-thalassemia in India","volume":"6","author":"Mehta","year":"2022","journal-title":"Hemasphere"},{"key":"10.25259\/ijmr_1986_23\/ref-28","doi-asserted-by":"crossref","first-page":"639208","DOI":"10.3389\/fmed.2021.639208","article-title":"Evaluation of microchip-based point-of-care device \u201cgazelle\u201d for diagnosis of sickle cell disease in India","volume":"8","author":"Shrivas","year":"2021","journal-title":"Front Med"}],"container-title":["The Indian Journal of Medical Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/ijmr.org.in\/assessment-of-diagnostic-accuracy-of-gazelle-a-point-of-care-testing-device-for-screening-thalassemia-trait\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/ijmr.org.in\/assessment-of-diagnostic-accuracy-of-gazelle-a-point-of-care-testing-device-for-screening-thalassemia-trait\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T22:30:02Z","timestamp":1734647402000},"score":1,"resource":{"primary":{"URL":"http:\/\/ijmr.org.in\/assessment-of-diagnostic-accuracy-of-gazelle-a-point-of-care-testing-device-for-screening-thalassemia-trait\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,22]]},"references-count":28,"alternative-id":["10.25259\/ijmr_1986_23"],"URL":"https:\/\/doi.org\/10.25259\/ijmr_1986_23","relation":{},"ISSN":["0971-5916"],"issn-type":[{"value":"0971-5916","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10,22]]},"article-number":"194"}}