{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T23:48:57Z","timestamp":1788997737144,"version":"build-2803163510"},"reference-count":19,"publisher":"Scientific Scholar","content-domain":{"domain":["clinicalimagingscience.org"],"crossmark-restriction":true},"short-container-title":["JCIS"],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>This study aims to evaluate the image quality of 55 keV virtual monoenergetic imaging (VMI) in carotid dual-energy computed tomography (CT) angiography (DE-CTA) reconstructed using deep learning image reconstruction (DLIR) algorithms and traditional iterative reconstruction algorithms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>This prospective study included 48 patients who underwent DE-CTA examinations at our institution between December 2024 and January 2025. Image reconstructions were performed using 50% strength adaptive statistical iterative reconstruction-Veo (ASIR-V 50%), low and high strengths DLIR (DLIR-L and DLIR-H) algorithms. Objective image quality was evaluated by measuring background noise (standard deviation), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) at key anatomical locations, including the aortic arch, common carotid artery, carotid bifurcation, and internal carotid artery. Two senior radiologists conducted subjective assessments of image quality, focusing on image noise, artifacts, and vessel continuity, and the clarity of vascular wall margin.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Compared with ASIR-V 50% and DLIR-L, DLIR-H significantly improved image quality by reducing background noise and increasing SNR and CNR (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; 0.05). Subjectively, DLIR-H images demonstrated better suppression of noise and clearer vascular wall margin (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; 0.05). Subgroup analysis revealed that these improvements were more pronounced in patients with a body mass index (BMI) \u226524 kg\/m\n                      <jats:sup>2<\/jats:sup>\n                      . No significant differences were observed in CT attenuations among the three reconstruction methods (\n                      <jats:italic>P<\/jats:italic>\n                      &gt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      At 55 keV VMI in carotid DE-CTA, DLIR-H significantly enhanced image quality, particularly by reducing noise and preserving fine anatomical structures. Its efficacy was especially notable in patients with BMI \u226524 kg\/m\n                      <jats:sup>2<\/jats:sup>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/jcis_109_2025","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T09:09:04Z","timestamp":1763024944000},"page":"42","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of image quality in carotid dual-energy computed tomography angiography at 55 keV virtual monoenergetic imaging using deep learning and adaptive iterative reconstruction algorithm"],"prefix":"10.25259","volume":"15","author":[{"given":"Xiaohan","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Long","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhongxiao","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meng","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenzi","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenbei","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"He","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aiyun","family":"Sun","sequence":"additional","affiliation":[{"name":"CT Imaging Research Center, GE HealthCare China, Shanghai, China,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuai","family":"Zhang","sequence":"additional","affiliation":[{"name":"CT Imaging Research Center, GE HealthCare China, Shanghai, China,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yankai","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"key":"10.25259\/JCIS_109_2025\/ref-1","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/S1474-4422(24)00369-7","article-title":"Global, regional, and national burden of stroke and its risk factors 1990-2021: A systematic analysis for the global burden of disease study 2021","volume":"23","author":"GBD 2021 Stroke Risk Factor Collaborators","year":"2024","journal-title":"Lancet Neurol"},{"key":"10.25259\/JCIS_109_2025\/ref-2","doi-asserted-by":"publisher","first-page":"2921","DOI":"10.1161\/STROKEAHA.123.035675","article-title":"Symptomatic nonstenotic carotids: A topical review","volume":"55","author":"Savastano","year":"2024","journal-title":"Stroke"},{"key":"10.25259\/JCIS_109_2025\/ref-3","doi-asserted-by":"publisher","first-page":"1499","DOI":"10.1007\/s00330-022-09247-8","article-title":"Correction to: State-of-the-art CT and MR imaging and assessment of atherosclerotic carotid artery disease: The reporting-a consensus document by the European Society of Cardiovascular Radiology (ESCR)","volume":"33","author":"Saba","year":"2023","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-4","doi-asserted-by":"publisher","first-page":"517","DOI":"10.2214\/AJR.21.26540","article-title":"Utility of dual-layer spectral detector CTA to characterize carotid atherosclerotic plaque components: An imaging-histopathology comparison in patients undergoing endarterectomy","volume":"218","author":"Li","year":"2022","journal-title":"Am J Roentgenol"},{"key":"10.25259\/JCIS_109_2025\/ref-5","doi-asserted-by":"publisher","first-page":"e032665","DOI":"10.1161\/JAHA.123.032665","article-title":"Application of dual-layer spectral-detector computed tomography angiography in identifying symptomatic carotid atherosclerosis: A prospective observational study","volume":"13","author":"Zhang","year":"2024","journal-title":"J Am Heart Assoc"},{"key":"10.25259\/JCIS_109_2025\/ref-6","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/s10140-020-01785-2","article-title":"Dual energy CT in clinical routine: How it works and how it adds value","volume":"28","author":"Sodickson","year":"2021","journal-title":"Emerg Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-7","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1016\/j.rcl.2023.05.002","article-title":"Dual-energy computed tomography: Technological considerations","volume":"61","author":"Chung","year":"2023","journal-title":"Radiol Clin Nam"},{"key":"10.25259\/JCIS_109_2025\/ref-8","doi-asserted-by":"publisher","first-page":"2501","DOI":"10.1016\/j.acra.2023.12.004","article-title":"Low dose iodinated contrast material and radiation for virtual monochromatic imaging in craniocervical dual-layer spectral detector computed tomography angiography: A prospective and randomized study","volume":"31","author":"Zhou","year":"2024","journal-title":"Acad Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-9","doi-asserted-by":"publisher","first-page":"e233","DOI":"10.1016\/j.acra.2018.07.019","article-title":"Combination of adaptive statistical iterative reconstruction-V and lower tube voltage during craniocervical computed tomographic angiography yields better image quality with a reduced radiation dose","volume":"26","author":"Chen","year":"2019","journal-title":"Acad Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-10","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.clinimag.2020.05.024","article-title":"Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography","volume":"68","author":"Chen","year":"2020","journal-title":"Clin Imaging"},{"key":"10.25259\/JCIS_109_2025\/ref-11","doi-asserted-by":"publisher","first-page":"2347","DOI":"10.1007\/s10278-023-00893-y","article-title":"A deep learning image reconstruction algorithm for improving image quality and hepatic lesion detectability in abdominal dual-energy computed tomography: Preliminary results","volume":"36","author":"Chu","year":"2023","journal-title":"J Digit Imaging"},{"key":"10.25259\/JCIS_109_2025\/ref-12","doi-asserted-by":"publisher","first-page":"20220625","DOI":"10.1259\/bjr.20220625","article-title":"Improving image quality with deep learning image reconstruction in double-low-dose head CT angiography compared with standard dose and adaptive statistical iterative reconstruction","volume":"96","author":"Huang","year":"2023","journal-title":"Br J Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-13","doi-asserted-by":"publisher","first-page":"5499","DOI":"10.1007\/s00330-022-08647-0","article-title":"Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen","volume":"32","author":"Sato","year":"2022","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-14","doi-asserted-by":"publisher","first-page":"1860","DOI":"10.21037\/qims-23-864","article-title":"Application of deep learning image reconstruction-high algorithm in one-stop coronary and carotid-cerebrovascular CT angiography with low radiation and contrast doses","volume":"14","author":"Li","year":"2024","journal-title":"Quant Imaging Med Surg"},{"key":"10.25259\/JCIS_109_2025\/ref-15","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1186\/s13244-022-01308-2","article-title":"Deep learning image reconstruction algorithm for carotid dual-energy computed tomography angiography: Evaluation of image quality and diagnostic performance","volume":"13","author":"Jiang","year":"2022","journal-title":"Insights Imaging"},{"key":"10.25259\/JCIS_109_2025\/ref-16","doi-asserted-by":"publisher","first-page":"2213","DOI":"10.1007\/s00330-024-11059-x","article-title":"Deep learning reconstruction algorithm and high-concentration contrast medium: Feasibility of a double-low protocol in coronary computed tomography angiography","volume":"35","author":"Caruso","year":"2025","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-17","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1007\/s00330-022-09025-6","article-title":"State-of-the-art CT and MR imaging and assessment of atherosclerotic carotid artery disease: The reporting-a consensus document by the European society of cardiovascular radiology (ESCR)","volume":"33","author":"Saba","year":"2023","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_109_2025\/ref-18","first-page":"2543","article-title":"Global, regional, and national progress towards the 2030 global nutrition targets and forecasts to 2050: A systematic analysis for the Global burden of disease study 2021","volume":"404","author":"Global Nutrition Target Collaborators","year":"2025","journal-title":"Lancet"},{"key":"10.25259\/JCIS_109_2025\/ref-19","doi-asserted-by":"publisher","first-page":"2955","DOI":"10.21037\/qims-23-1602","article-title":"The application value of a vendor-specific deep learning image reconstruction algorithm in \u201ctriple low\u201d head and neck computed tomography angiography","volume":"14","author":"Zhang","year":"2024","journal-title":"Quant Imag Med Surg"}],"container-title":["Journal of Clinical Imaging Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/clinicalimagingscience.org\/comparison-of-image-quality-in-carotid-dual-energy-computed-tomography-angiography-at-55-kev-virtual-monoenergetic-imaging-using-deep-learning-and-adaptive-iterative-reconstruction-algorithm\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/clinicalimagingscience.org\/comparison-of-image-quality-in-carotid-dual-energy-computed-tomography-angiography-at-55-kev-virtual-monoenergetic-imaging-using-deep-learning-and-adaptive-iterative-reconstruction-algorithm\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T09:09:04Z","timestamp":1763024944000},"score":1,"resource":{"primary":{"URL":"https:\/\/clinicalimagingscience.org\/comparison-of-image-quality-in-carotid-dual-energy-computed-tomography-angiography-at-55-kev-virtual-monoenergetic-imaging-using-deep-learning-and-adaptive-iterative-reconstruction-algorithm\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,13]]},"references-count":19,"alternative-id":["10.25259\/JCIS_109_2025"],"URL":"https:\/\/doi.org\/10.25259\/jcis_109_2025","relation":{},"ISSN":["2156-5597","2156-7514"],"issn-type":[{"value":"2156-5597","type":"electronic"},{"value":"2156-7514","type":"print"}],"subject":[],"published":{"date-parts":[[2025,11,13]]},"article-number":"42"}}