{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T10:07:33Z","timestamp":1771236453379,"version":"3.50.1"},"reference-count":21,"publisher":"Scientific Scholar","content-domain":{"domain":["clinicalimagingscience.org"],"crossmark-restriction":true},"short-container-title":["JCIS"],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The objective of the study is to determine the contrast-specific conversion factor (cCF) based on the dose differences between non-enhanced computed tomography (NECT) and contrast-enhanced CT (CECT) in abdominal imaging, with the aim of improving the accuracy of radiation dose estimation in contrast-enhanced examinations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>The study included 33 adult patients who underwent both NECT and CECT. CECT image acquisition commenced 80 s after the start of iodinated contrast medium injection. A Monte Carlo simulation tool was used to estimate the radiation dose delivered to each patient during NECT and CECT. Organ doses for the liver, spleen, and both kidneys were measured using 120-kVp images. The cCF was calculated as the ratio of the organ dose in CECT to that in NECT. The cCF values are dependent on the scan protocol-, CT vendor-, and X-ray photon energy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The mean organ doses during NECT were 10.45 mGy for the liver, 11.19 mGy for the spleen, and 11.47 mGy for both kidneys. During CECT, these values increased to 15.83 mGy, 17.56 mGy, and 20.75 mGy, respectively. The mean cCFs of CECT relative to NECT were 1.52 for the liver, 1.83 for the spleen, and 1.87 for both kidneys.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Applying the cCF to NECT-based dose estimates enables more accurate assessment of radiation exposure in CECT examinations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/jcis_151_2025","type":"journal-article","created":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T09:18:13Z","timestamp":1771233493000},"page":"7","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Contrast-specific conversion factor for accurate radiation dose estimation in contrast-enhanced abdominal computed tomography"],"prefix":"10.25259","volume":"16","author":[{"given":"Yoshinori","family":"Funama","sequence":"first","affiliation":[{"name":"Department of Medical Image Analysis, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Sakabe","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kumamoto University, Kumamoto, Japan,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Nakaura","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Kumamoto University, Kumamoto, Japan,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seitaro","family":"Oda","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Kumamoto University, Kumamoto, Japan,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masafumi","family":"Kidoh","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Kumamoto University, Kumamoto, Japan,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasunori","family":"Nagayama","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Kumamoto University, Kumamoto, Japan,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshinori","family":"Hirai","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Kumamoto University, Kumamoto, Japan,"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2026,2,16]]},"reference":[{"key":"10.25259\/JCIS_151_2025\/ref-1","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1016\/S0140-6736(04)16374-5","article-title":"Risk of cancer from diagnostic X-rays: Estimates for the UK and 14 other countries","volume":"363","author":"De Gonzalez","year":"2004","journal-title":"Lancet"},{"key":"10.25259\/JCIS_151_2025\/ref-2","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography--an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N Engl J Med"},{"key":"10.25259\/JCIS_151_2025\/ref-3","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1001\/jamainternmed.2025.0505","article-title":"Projected lifetime cancer risks from current computed tomography imaging","volume":"185","author":"Smith-Bindman","year":"2025","journal-title":"JAMA Intern Med"},{"key":"10.25259\/JCIS_151_2025\/ref-4","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1186\/s12885-022-10310-2","article-title":"CT scans and cancer risks: A systematic review and dose-response meta-analysis","volume":"22","author":"Cao","year":"2022","journal-title":"BMC Cancer"},{"key":"10.25259\/JCIS_151_2025\/ref-5","doi-asserted-by":"publisher","first-page":"3111","DOI":"10.1038\/s41591-023-02620-0","article-title":"Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults","volume":"29","author":"Bosch De Basea","year":"2023","journal-title":"Nat Med"},{"key":"10.25259\/JCIS_151_2025\/ref-6","doi-asserted-by":"publisher","first-page":"2148","DOI":"10.1002\/ijc.35318","article-title":"Risk of childhood brain tumors after exposure to CT radiation: A nationwide population-based case-control study in Finland","volume":"156","author":"Abuhamed","year":"2025","journal-title":"Int J Cancer"},{"key":"10.25259\/JCIS_151_2025\/ref-7","doi-asserted-by":"publisher","first-page":"881","DOI":"10.2214\/AJR.09.3462","article-title":"Estimating effective dose for CT using dose-length product compared with using organ doses: Consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning","volume":"194","author":"Christner","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"10.25259\/JCIS_151_2025\/ref-8","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1148\/radiol.10100047","article-title":"Multisection CT protocols: Sex-and age-specific conversion factors used to determine effective dose from dose-length product","volume":"257","author":"Deak","year":"2010","journal-title":"Radiology"},{"key":"10.25259\/JCIS_151_2025\/ref-9","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1148\/radiol.10100297","article-title":"Volume CT dose index and dose-length product displayed during CT: What good are they?","volume":"258","author":"Huda","year":"2011","journal-title":"Radiology"},{"key":"10.25259\/JCIS_151_2025\/ref-10","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1148\/radiol.12112365","article-title":"Size-specific dose estimates for adult patients at CT of the torso","volume":"265","author":"Christner","year":"2012","journal-title":"Radiology"},{"key":"10.25259\/JCIS_151_2025\/ref-11","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1148\/radiol.12120131","article-title":"Investigation of American association of physicists in medicine report 204 size-specific dose estimates for pediatric CT implementation","volume":"265","author":"Brady","year":"2012","journal-title":"Radiology"},{"key":"10.25259\/JCIS_151_2025\/ref-12","doi-asserted-by":"publisher","first-page":"4249","DOI":"10.1118\/1.3460797","article-title":"A method to evaluate the dose increase in CT with iodinated contrast medium","volume":"37","author":"Amato","year":"2010","journal-title":"Med Phys"},{"key":"10.25259\/JCIS_151_2025\/ref-13","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1148\/radiol.2016152851","article-title":"The effect of contrast material on radiation dose at CT: Part I. Incorporation of contrast material dynamics in anthropomorphic phantoms","volume":"283","author":"Sahbaee","year":"2017","journal-title":"Radiology"},{"key":"10.25259\/JCIS_151_2025\/ref-14","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1148\/radiol.2017152852","article-title":"The effect of contrast material on radiation dose at CT: Part II. A systematic evaluation across 58 patient models","volume":"283","author":"Sahbaee","year":"2017","journal-title":"Radiology"},{"key":"10.25259\/JCIS_151_2025\/ref-15","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1118\/1.596686","article-title":"Semiempirical model for generating tungsten target x-ray spectra","volume":"18","author":"Tucker","year":"1991","journal-title":"Med Phys"},{"key":"10.25259\/JCIS_151_2025\/ref-16","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1118\/1.3551990","article-title":"Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe","volume":"38","author":"McKenney","year":"2011","journal-title":"Med Phys"},{"key":"10.25259\/JCIS_151_2025\/ref-17","doi-asserted-by":"publisher","first-page":"e128","DOI":"10.1016\/j.ejrad.2011.05.012","article-title":"Effect of contrast material on image noise and radiation dose in adult chest computed tomography using automatic exposure control: A comparative study between 16-, 64-and 128-slice CT","volume":"79","author":"Paul","year":"2011","journal-title":"Eur J Radiol"},{"key":"10.25259\/JCIS_151_2025\/ref-18","doi-asserted-by":"publisher","first-page":"1288","DOI":"10.2214\/AJR.12.8958","article-title":"Can contrast media increase organ doses in CT examinations? A clinical study","volume":"200","author":"Amato","year":"2013","journal-title":"AJR Am J Roentgenol"},{"key":"10.25259\/JCIS_151_2025\/ref-19","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/s00330-017-4970-1","article-title":"The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry","volume":"28","author":"Perisinakis","year":"2018","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_151_2025\/ref-20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0958-3947(01)00078-4","article-title":"Effective atomic numbers for photon energy absorption and photon attenuation of tissues from human organs","volume":"27","author":"Shivaramu","year":"2002","journal-title":"Med Dosim"},{"key":"10.25259\/JCIS_151_2025\/ref-21","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1118\/1.2815936","article-title":"Energy dependence of effective atomic numbers for photon energy absorption and photon interaction: Studies of some biological molecules in the energy range 1 keV-20 MeV","volume":"35","author":"Manohara","year":"2008","journal-title":"Med Phys"}],"container-title":["Journal of Clinical Imaging Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/clinicalimagingscience.org\/contrast-specific-conversion-factor-for-accurate-radiation-dose-estimation-in-contrast-enhanced-abdominal-computed-tomography\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/clinicalimagingscience.org\/contrast-specific-conversion-factor-for-accurate-radiation-dose-estimation-in-contrast-enhanced-abdominal-computed-tomography\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T09:18:14Z","timestamp":1771233494000},"score":1,"resource":{"primary":{"URL":"https:\/\/clinicalimagingscience.org\/contrast-specific-conversion-factor-for-accurate-radiation-dose-estimation-in-contrast-enhanced-abdominal-computed-tomography\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,16]]},"references-count":21,"alternative-id":["10.25259\/JCIS_151_2025"],"URL":"https:\/\/doi.org\/10.25259\/jcis_151_2025","relation":{},"ISSN":["2156-5597","2156-7514"],"issn-type":[{"value":"2156-5597","type":"electronic"},{"value":"2156-7514","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2,16]]},"article-number":"7"}}