{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T15:04:14Z","timestamp":1784127854520,"version":"3.55.0"},"reference-count":25,"publisher":"Scientific Scholar","content-domain":{"domain":["clinicalimagingscience.org"],"crossmark-restriction":true},"short-container-title":["JCIS"],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Objectives:<\/jats:title>\n<jats:p>The objective of the study was to evaluate the efficacy of ultra-high-resolution computed tomography (UHRCT) in comparison to conventional resolution computed tomography (CT) for the characterization of lung nodules.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Material and Methods:<\/jats:title>\n<jats:p>104 non-contrast chest UHRCT scans (mean age of 66 years, 57 females) with pulmonary nodules were retrospectively collected (February\u2013November 2022), and corresponding normal-resolution (NR) reconstructions were synthesized using a validated algorithm. Five blinded radiologists scored the following for each localized nodule in the ultra-high-resolution (UHR) and NR datasets: Margin clarity (5-point Likert scale), image quality \u201cIQ\u201d (3-point), density confidence (0\u2013100%), and size (long\/short axes). Image noise (voxel standard deviation) was calculated within the trachea. Differences between UHR and NR were tested using the Wilcoxon signed-rank test. Intrareader agreement was quantified with intraclass correlation coefficient (ICC), and ordinal association between margin clarity and IQ was quantified with Kendall\u2019s <jats:italic>\u03c4<\/jats:italic> coefficient.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Results:<\/jats:title>\n<jats:p>Margin clarity, IQ, and density confidence were significantly higher for UHR (<jats:italic>P<\/jats:italic> &lt; 0.001). No significant differences between UHR and NR were observed in the variability (standard deviation across readers) for measuring long and short axes (<jats:italic>P<\/jats:italic> &gt; 0.100). Intrareader agreement for UHR and NR was poor for margin clarity, IQ, and density confidences (ICC &lt; 0.250) but moderate for short axes (ICC = 0.731) and good for long axes (ICC = 0.807). Ordinal association between margin clarity and IQ was moderate for UHR (<jats:italic>\u03c4<\/jats:italic> = 0.566) and good for IQ (<jats:italic>\u03c4<\/jats:italic> = 0.637). Image noise was significantly higher (<jats:italic>P<\/jats:italic> &lt; 0.001) for UHR compared to NR.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st4\">\n<jats:title>Conclusion:<\/jats:title>\n<jats:p>UHRCT offers significant improvements in the visualization of lung nodules compared to conventional resolution CT, albeit with an increase in image noise.<\/jats:p>\n<\/jats:sec>","DOI":"10.25259\/jcis_17_2025","type":"journal-article","created":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T05:17:07Z","timestamp":1752124627000},"page":"25","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A multireader, multicase study comparing ultra-high-resolution and conventional-resolution computed tomography for lung nodule characterization"],"prefix":"10.25259","volume":"15","author":[{"given":"Andrew M.","family":"Hernandez","sequence":"first","affiliation":[{"name":"Department of Radiology, University of California Davis, Sacramento, California, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony F.","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California Davis, Sacramento, California, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatma","family":"Sen","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California Davis, Sacramento, California, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana S.","family":"Mitchell","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California Davis, Sacramento, California, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah E.","family":"McKenney","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California Davis, Sacramento, California, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Nardo","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California Davis, Sacramento, California, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig K.","family":"Abbey","sequence":"additional","affiliation":[{"name":"Department of Psychological and Brain Sciences, University of California, Santa Barbara, California, United States,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad H.","family":"Madani","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of California Davis, Sacramento, California, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2025,7,8]]},"reference":[{"key":"10.25259\/JCIS_17_2025\/ref-1","doi-asserted-by":"publisher","first-page":"e93S","DOI":"10.1378\/chest.12-2351","article-title":"Evaluation of individuals with pulmonary nodules: When is it lung cancer? Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines","volume":"143","author":"Gould","year":"2013","journal-title":"Chest"},{"key":"10.25259\/JCIS_17_2025\/ref-2","doi-asserted-by":"publisher","first-page":"170025","DOI":"10.1183\/16000617.0025-2017","article-title":"Lung nodules: Size still matters","volume":"26","author":"Larici","year":"2017","journal-title":"Eur Respir Rev"},{"key":"10.25259\/JCIS_17_2025\/ref-3","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/s13244-017-0581-2","article-title":"Evaluation of the solitary pulmonary nodule: Size matters, but do not ignore the power of morphology","volume":"9","author":"Snoeckx","year":"2018","journal-title":"Insights Imaging"},{"key":"10.25259\/JCIS_17_2025\/ref-4","doi-asserted-by":"publisher","first-page":"ii1","DOI":"10.1136\/thoraxjnl-2015-207168","article-title":"British Thoracic Society guidelines for the investigation and management of pulmonary nodules","volume":"70","author":"Callister","year":"2015","journal-title":"Thorax"},{"key":"10.25259\/JCIS_17_2025\/ref-5","article-title":"Lung-RADS assessment categories","year":"2022"},{"key":"10.25259\/JCIS_17_2025\/ref-6","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1148\/radiol.2017161659","article-title":"Guidelines for management of incidental pulmonary nodules detected on CT images: From the Fleischner society 2017","volume":"284","author":"MacMahon","year":"2017","journal-title":"Radiology"},{"key":"10.25259\/JCIS_17_2025\/ref-7","doi-asserted-by":"publisher","first-page":"754","DOI":"10.6004\/jnccn.2022.0036","article-title":"NCCN Guidelines (R) insights: Lung cancer screening, version 1.2022","volume":"20","author":"Wood","year":"2022","journal-title":"J Natl Compr Canc Netw"},{"key":"10.25259\/JCIS_17_2025\/ref-8","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/j.acra.2017.11.017","article-title":"Effect of matrix size on the image quality of ultra-high-resolution CT of the lung: Comparison of 512 x 512, 1024 x 1024, and 2048 x 2048","volume":"25","author":"Hata","year":"2018","journal-title":"Acad Radiol"},{"key":"10.25259\/JCIS_17_2025\/ref-9","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s00234-017-1927-7","article-title":"Ultra-high-resolution CT angiography of the artery of Adamkiewicz: A feasibility study","volume":"60","author":"Yoshioka","year":"2018","journal-title":"Neuroradiology"},{"key":"10.25259\/JCIS_17_2025\/ref-10","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1109\/TRPMS.2020.3020212","article-title":"Photon Counting CT: Clinical applications and future developments","volume":"5","author":"Hsieh","year":"2021","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"key":"10.25259\/JCIS_17_2025\/ref-11","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1148\/rg.2019180115","article-title":"Photon-counting detector CT: System design and clinical applications of an emerging technology","volume":"39","author":"Leng","year":"2019","journal-title":"Radiographics"},{"key":"10.25259\/JCIS_17_2025\/ref-12","doi-asserted-by":"publisher","first-page":"2760","DOI":"10.1002\/mp.14789","article-title":"Location and direction dependence in the 3D MTF for a high-resolution CT system","volume":"48","author":"Hernandez","year":"2021","journal-title":"Med Phys"},{"key":"10.25259\/JCIS_17_2025\/ref-13","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1002\/mp.16194","article-title":"Performance of high-resolution CT for detection and discrimination tasks related to stenotic lesions-A phantom study using model observers","volume":"50","author":"Hernandez","year":"2023","journal-title":"Med Phys"},{"key":"10.25259\/JCIS_17_2025\/ref-14","doi-asserted-by":"publisher","first-page":"e210053","DOI":"10.1148\/ryct.2021210053","article-title":"Ultra-high-resolution coronary CT angiography for assessment of patients with severe coronary artery calcification: Initial experience","volume":"3","author":"Latina","year":"2021","journal-title":"Radiol Cardiothorac Imaging"},{"key":"10.25259\/JCIS_17_2025\/ref-15","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1148\/radiol.2020201911","article-title":"Lung adenocarcinoma at CT with 0.25-mm section thickness and a 2048 matrix: High-spatial-resolution imaging for predicting invasiveness","volume":"297","author":"Yanagawa","year":"2020","journal-title":"Radiology"},{"key":"10.25259\/JCIS_17_2025\/ref-16","doi-asserted-by":"publisher","first-page":"043502","DOI":"10.1117\/1.JMI.4.4.043502","article-title":"Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system","volume":"4","author":"Zhou","year":"2017","journal-title":"J Med Imaging (Bellingham)"},{"key":"10.25259\/JCIS_17_2025\/ref-17","doi-asserted-by":"publisher","first-page":"15119","DOI":"10.1038\/s41598-021-94596-5","article-title":"Detectability of pulmonary ossifications in fibrotic lung on ultra-high-resolution CT using 2048 matrix size and 0.25-mm slice thickness","volume":"11","author":"Hata","year":"2021","journal-title":"Sci Rep"},{"key":"10.25259\/JCIS_17_2025\/ref-18","doi-asserted-by":"publisher","first-page":"878","DOI":"10.1007\/s11604-020-00987-5","article-title":"Improved image quality of temporal bone CT with an ultrahigh-resolution CT scanner: Clinical pilot studies","volume":"38","author":"Ohara","year":"2020","journal-title":"Jpn J Radiol"},{"key":"10.25259\/JCIS_17_2025\/ref-19","doi-asserted-by":"publisher","first-page":"109033","DOI":"10.1016\/j.ejrad.2020.109033","article-title":"Ultra high-resolution computed tomography with 1024-matrix: Comparison with 512-matrix for the evaluation of pulmonary nodules","volume":"128","author":"Tsubamoto","year":"2020","journal-title":"Eur J Radiol"},{"key":"10.25259\/JCIS_17_2025\/ref-20","doi-asserted-by":"publisher","first-page":"4775","DOI":"10.1002\/mp.14395","article-title":"Validation of synthesized normal-resolution image data generated from high-resolution acquisitions on a commercial CT scanner","volume":"47","author":"Hernandez","year":"2020","journal-title":"Med Phys"},{"key":"10.25259\/JCIS_17_2025\/ref-21","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/S1076-6332(03)80479-8","article-title":"Independent versus sequential reading in ROC studies of computer-assist modalities: Analysis of components of variance","volume":"9","author":"Beiden","year":"2002","journal-title":"Acad Radiol"},{"key":"10.25259\/JCIS_17_2025\/ref-22","doi-asserted-by":"publisher","first-page":"20211028","DOI":"10.1259\/bjr.20211028","article-title":"COVID-19 pneumonia chest radiographic severity score: Variability assessment among experienced and in-training radiologists and creation of a multireader composite score database for artificial intelligence algorithm development","volume":"95","author":"van Assen","year":"2022","journal-title":"Br J Radiol"},{"key":"10.25259\/JCIS_17_2025\/ref-23","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1037\/1082-989X.1.1.30","article-title":"Forming inferences about some intraclass correlation coefficients","volume":"1","author":"McGraw","year":"1996","journal-title":"Psychol Methods"},{"key":"10.25259\/JCIS_17_2025\/ref-24","doi-asserted-by":"publisher","first-page":"5060","DOI":"10.1007\/s00330-018-5491-2","article-title":"Subjective and objective comparisons of image quality between ultra-high-resolution CT and conventional area detector CT in phantoms and cadaveric human lungs","volume":"28","author":"Yanagawa","year":"2018","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_17_2025\/ref-25","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1097\/RLI.0000000000000524","article-title":"High-resolution chest computed tomography imaging of the lungs: Impact of 1024 matrix reconstruction and photon-counting detector computed tomography","volume":"54","author":"Bartlett","year":"2019","journal-title":"Invest Radiol"}],"container-title":["Journal of Clinical Imaging Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/clinicalimagingscience.org\/a-multireader-multicase-study-comparing-ultra-high-resolution-and-conventional-resolution-computed-tomography-for-lung-nodule-characterization\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/clinicalimagingscience.org\/a-multireader-multicase-study-comparing-ultra-high-resolution-and-conventional-resolution-computed-tomography-for-lung-nodule-characterization\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T05:17:08Z","timestamp":1752124628000},"score":1,"resource":{"primary":{"URL":"https:\/\/clinicalimagingscience.org\/a-multireader-multicase-study-comparing-ultra-high-resolution-and-conventional-resolution-computed-tomography-for-lung-nodule-characterization\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,8]]},"references-count":25,"alternative-id":["10.25259\/JCIS_17_2025"],"URL":"https:\/\/doi.org\/10.25259\/jcis_17_2025","relation":{},"ISSN":["2156-5597","2156-7514"],"issn-type":[{"value":"2156-5597","type":"electronic"},{"value":"2156-7514","type":"print"}],"subject":[],"published":{"date-parts":[[2025,7,8]]},"article-number":"25"}}