{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T09:55:07Z","timestamp":1774000507297,"version":"3.50.1"},"reference-count":35,"publisher":"Scientific Scholar","content-domain":{"domain":["clinicalimagingscience.org"],"crossmark-restriction":true},"short-container-title":["JCIS"],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>This study aims to compare the effects of deep learning image reconstruction (DLIR) and adaptive statistical iterative reconstruction-veo (ASIR-V) algorithms on the image quality of cranial computed tomography angiography (CTA) reconstructed from computed tomography perfusion (CTP) data and to evaluate their agreement with digital subtraction angiography (DSA), the gold standard for diagnosing arterial stenosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>This retrospective study enrolled patients with clinically suspected cerebrovascular disease who had undergone CTP examination. From the arterial peak phase of CTP raw data, four CTA datasets were reconstructed: ASIR-V 40%, ASIR-V 80%, DLIR low setting (DLIR-L), and DLIR high setting (DLIR-H). Regions of interest were placed at the M1 segment of the middle cerebral artery (MCA), basilar artery (BA), and internal carotid artery (ICA) on the healthy side and the temporalis muscle. Computed tomography attenuation values and standard deviations were measured, and the contrast-to-noise ratio(CNR) and signal-to-noise ratio (SNR) were subsequently calculated using the attenuation values and standard deviations. Vessel edge sharpness was objectively assessed using edge rise distance (ERD) and edge rise slope (ERS). Using DSA as the reference standard, diagnostic performance for vascular stenosis was evaluated, and agreement was analyzed with the Kappa test. Two radiologists independently scored subjective image quality using a 5-point Likert scale.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Sixty-five patients were included, 14 of whom additionally underwent DSA. For the MCA, ICA, and BA, image noise in the DLIR-H group was significantly lower than that in the other groups, with statistically significant differences compared with ASIR-V 40% (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05). For CNR and SNR, DLIR-H and ASIR-V 80% outperformed ASIR-V 40% and DLIR-L across all arterial levels (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05). ERD and ERS were significantly superior in the DLIR groups compared with the ASIR-V groups (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05). In subjective evaluations, the DLIR-H group achieved the highest scores across all parameters (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05). Agreement with DSA was excellent for DLIR-H (\u03ba = 0.819), significantly higher than for ASIR-V (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In CTP examinations for suspected cerebrovascular disease, DLIR-H markedly improves cranial CTA image quality compared with ASIR-V, while achieving higher diagnostic agreement with DSA. DLIR-H can be recommended as the preferred clinical reconstruction method.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/jcis_226_2025","type":"journal-article","created":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T10:24:57Z","timestamp":1773743097000},"page":"12","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optimization of image quality and diagnostic accuracy for vascular stenosis in computed tomography perfusion-reconstructed cerebral computed tomography angiography using deep learning reconstruction"],"prefix":"10.25259","volume":"16","author":[{"given":"Lulu","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Medical Technology, Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xianghao","family":"Feng","sequence":"additional","affiliation":[{"name":"School of Medical Technology, Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"He","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dapeng","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Houliang","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qihang","family":"Sun","sequence":"additional","affiliation":[{"name":"School of Medicine and Health, Technical University of Munich, Munich, Germany,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yankai","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China,"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cunjie","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Radiology, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China,"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2026,3,17]]},"reference":[{"key":"10.25259\/JCIS_226_2025\/ref-1","doi-asserted-by":"publisher","first-page":"110591","DOI":"10.1016\/j.clinbiochem.2023.110591","article-title":"Effects of vitamin B12 deficiency on risk and outcome of ischemic stroke","volume":"118","author":"Zhou","year":"2023","journal-title":"Clinical Biochem"},{"key":"10.25259\/JCIS_226_2025\/ref-2","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1016\/S1474-4422(21)00252-0","article-title":"Global, regional, and national burden of stroke and its risk factors 1990-2019: A systematic analysis for the global burden of disease study 2019","volume":"20","author":"GBD 2019 Stroke Collaborators","year":"2021","journal-title":"Lancet Neurol"},{"key":"10.25259\/JCIS_226_2025\/ref-3","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1111\/ane.13343","article-title":"Inhospital acute stroke workflow in acute stroke-systems-based approaches","volume":"143","author":"Santana Baskar","year":"2021","journal-title":"Acta Neurol Scand"},{"key":"10.25259\/JCIS_226_2025\/ref-4","doi-asserted-by":"publisher","first-page":"2515","DOI":"10.1109\/TMI.2025.3540886","article-title":"DSCA: A digital subtraction angiography sequence dataset and spatio-temporal model for cerebral artery segmentation","volume":"44","author":"Zhang","year":"2025","journal-title":"IEEE Trans Med Imaging"},{"key":"10.25259\/JCIS_226_2025\/ref-5","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1177\/0271678X19831024","article-title":"Signal variance-based collateral index in DSC perfusion: A novel method to assess leptomeningeal collateralization in acute ischaemic stroke","volume":"40","author":"Seiler","year":"2020","journal-title":"J Cereb Blood Flow Metab"},{"key":"10.25259\/JCIS_226_2025\/ref-6","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1038\/s41572-019-0118-8","article-title":"Ischaemic stroke","volume":"5","author":"Campbell","year":"2019","journal-title":"Nat Rev Dis Primers"},{"key":"10.25259\/JCIS_226_2025\/ref-7","doi-asserted-by":"publisher","first-page":"8717","DOI":"10.1088\/1361-6560\/ac8717","article-title":"Basis and current state of computed tomography perfusion imaging: A review","volume":"67","author":"Zeng","year":"2022","journal-title":"Phys Med Biol"},{"key":"10.25259\/JCIS_226_2025\/ref-8","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1186\/s12880-024-01373-7","article-title":"Contrast enhancement boost improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data","volume":"24","author":"Yang","year":"2024","journal-title":"BMC Med Imaging"},{"key":"10.25259\/JCIS_226_2025\/ref-9","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.3174\/ajnr.A4162","article-title":"4D-CTA in neurovascular disease: A review","volume":"36","author":"Kortman","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/JCIS_226_2025\/ref-10","doi-asserted-by":"publisher","first-page":"4922","DOI":"10.1007\/s00330-019-06027-9","article-title":"Comparison of CT angiography collaterals for predicting target perfusion profile and clinical outcome in patients with acute ischemic stroke","volume":"29","author":"Lu","year":"2019","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-11","doi-asserted-by":"publisher","first-page":"071911","DOI":"10.1118\/1.4884038","article-title":"Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance","volume":"41","author":"Li","year":"2014","journal-title":"Med Phys"},{"key":"10.25259\/JCIS_226_2025\/ref-12","doi-asserted-by":"publisher","first-page":"3974","DOI":"10.1007\/s00330-021-08459-8","article-title":"Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: Assessment of image quality and radiation dose in a phantom study","volume":"32","author":"Park","year":"2022","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-13","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1016\/j.acra.2019.02.022","article-title":"Reducing radiation dose and improving image quality in CT portal venography using 80 kV and adaptive statistical iterative reconstruction-V in slender patients","volume":"27","author":"Ren","year":"2020","journal-title":"Acad Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-14","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1186\/s13244-022-01308-2","article-title":"Deep learning image reconstruction algorithm for carotid dual-energy computed tomography angiography: Evaluation of image quality and diagnostic performance","volume":"13","author":"Jiang","year":"2022","journal-title":"Insights Imaging"},{"key":"10.25259\/JCIS_226_2025\/ref-15","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1007\/s42979-021-00815-1","article-title":"Deep learning: A comprehensive overview on techniques taxonomy applications and research directions","volume":"2","author":"Sarker","year":"2021","journal-title":"SN Comput Sci"},{"key":"10.25259\/JCIS_226_2025\/ref-16","doi-asserted-by":"publisher","first-page":"6194","DOI":"10.1109\/TNNLS.2021.3072746","article-title":"On the sufficient condition for solving the gap-filling problem using deep convolutional neural networks","volume":"33","author":"Peppert","year":"2022","journal-title":"IEEE Trans Neural Netw Learn Syst"},{"key":"10.25259\/JCIS_226_2025\/ref-17","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1007\/s11547-021-01384-2","article-title":"Performance evaluation of a deep learning image reconstruction (DLIR) algorithm in \u201cdouble low\u201d chest CTA in children: A feasibility study","volume":"126","author":"Sun","year":"2021","journal-title":"Radiol Med"},{"key":"10.25259\/JCIS_226_2025\/ref-18","doi-asserted-by":"publisher","first-page":"5331","DOI":"10.1007\/s00330-023-09556-6","article-title":"Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: A prospective study with five readers","volume":"33","author":"Zhong","year":"2023","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-19","doi-asserted-by":"publisher","first-page":"2384","DOI":"10.1007\/s00330-023-10171-8","article-title":"Low-dose liver CT: Image quality and diagnostic accuracy of deep learning image reconstruction algorithm","volume":"34","author":"Caruso","year":"2024","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-20","doi-asserted-by":"publisher","first-page":"2712","DOI":"10.1007\/s00330-019-06650-6","article-title":"Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: A comparative study","volume":"30","author":"Abdellatif","year":"2020","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-21","doi-asserted-by":"publisher","first-page":"881","DOI":"10.2214\/AJR.09.3462","article-title":"Estimating effective dose for CT using dose-length product compared with using organ doses: Consequences of adopting international commission on radiological protection publication 103 or dual-energy scanning","volume":"194","author":"Christner","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"10.25259\/JCIS_226_2025\/ref-22","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1186\/s12880-022-00834-1","article-title":"Assessment of low-dose paranasal sinus CT imaging using a new deep learning image reconstruction technique in children compared to adaptive statistical iterative reconstruction V (ASiR-V)","volume":"22","author":"Li","year":"2022","journal-title":"BMC Med Imaging"},{"key":"10.25259\/JCIS_226_2025\/ref-23","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s00234-020-02574-x","article-title":"Deep learning-based image reconstruction for brain CT: Improved image quality compared with adaptive statistical iterative reconstruction-Veo (ASIR-V)","volume":"63","author":"Kim","year":"2021","journal-title":"Neuroradiology"},{"key":"10.25259\/JCIS_226_2025\/ref-24","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1148\/radiol.210551","article-title":"Deep learning reconstruction shows better lung nodule detection for ultra-low-dose chest CT","volume":"303","author":"Jiang","year":"2022","journal-title":"Radiology"},{"key":"10.25259\/JCIS_226_2025\/ref-25","doi-asserted-by":"publisher","first-page":"8173","DOI":"10.21037\/qims-23-547","article-title":"The value of a deep learning image reconstruction algorithm in whole-brain computed tomography perfusion in patients with acute ischemic stroke","volume":"13","author":"Lei","year":"2023","journal-title":"Quant Imaging Med Surg"},{"key":"10.25259\/JCIS_226_2025\/ref-26","doi-asserted-by":"publisher","first-page":"112276","DOI":"10.1016\/j.ejrad.2025.112276","article-title":"Comparison of image quality of 40 keV virtual monoenergetic images of vertebral arteries using DLIR and ASIR-V algorithms under a dual-low scanning protocol","volume":"191","author":"Tang","year":"2025","journal-title":"Eur J Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-27","doi-asserted-by":"publisher","first-page":"2955","DOI":"10.21037\/qims-23-1602","article-title":"The application value of a vendor-specific deep learning image reconstruction algorithm in \u201ctriple low\u201d head and neck computed tomography angiography","volume":"14","author":"Zhang","year":"2024","journal-title":"Quant Imaging Med Surg"},{"key":"10.25259\/JCIS_226_2025\/ref-28","doi-asserted-by":"publisher","first-page":"20150463","DOI":"10.1259\/bjr.20150463","article-title":"The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: Comparison with the adaptive statistical iterative reconstruction technique","volume":"88","author":"Kwon","year":"2015","journal-title":"Br J Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-29","doi-asserted-by":"publisher","first-page":"1616","DOI":"10.21037\/qims-23-1064","article-title":"Effect of deep learning image reconstruction with high-definition standard scan mode on image quality of coronary stents and arteries","volume":"14","author":"Liu","year":"2024","journal-title":"Quant Imaging Med Surg"},{"key":"10.25259\/JCIS_226_2025\/ref-30","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/s00234-019-02313-x","article-title":"Ultra-low-dose multiphase CT angiography derived from CT perfusion data in patients with middle cerebral artery stenosis","volume":"62","author":"Wu","year":"2020","journal-title":"Neuroradiology"},{"key":"10.25259\/JCIS_226_2025\/ref-31","doi-asserted-by":"publisher","first-page":"163","DOI":"10.3892\/etm.2017.4451","article-title":"Feasibility of dual-low scheme combined with iterative reconstruction technique in acute cerebral infarction volume CT whole brain perfusion imaging","volume":"14","author":"Wang","year":"2017","journal-title":"Exp Ther Med"},{"key":"10.25259\/JCIS_226_2025\/ref-32","doi-asserted-by":"publisher","first-page":"20220196","DOI":"10.1259\/bjr.20220196","article-title":"Iterative reconstruction vs deep learning image reconstruction: Comparison of image quality and diagnostic accuracy of arterial stenosis in low-dose lower extremity CT angiography","volume":"95","author":"Qu","year":"2022","journal-title":"Br J Radiol"},{"key":"10.25259\/JCIS_226_2025\/ref-33","doi-asserted-by":"publisher","first-page":"2933","DOI":"10.21037\/qims-22-186","article-title":"Improving image quality and resolution of coronary arteries in coronary computed tomography angiography by using high-definition scans and deep learning image reconstruction","volume":"13","author":"Wang","year":"2023","journal-title":"Quant Imaging Med Surg"},{"key":"10.25259\/JCIS_226_2025\/ref-34","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.2214\/AJR.17.19102","article-title":"A third-generation adaptive statistical iterative reconstruction technique: Phantom study of image noise, spatial resolution, lesion detectability, and dose reduction potential","volume":"210","author":"Euler","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"10.25259\/JCIS_226_2025\/ref-35","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ejmp.2020.06.004","article-title":"Task-based characterization of a deep learning image reconstruction and comparison with filtered back-projection and a partial model-based iterative reconstruction in abdominal CT: A phantom study","volume":"76","author":"Racine","year":"2020","journal-title":"Phys Med"}],"container-title":["Journal of Clinical Imaging Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/clinicalimagingscience.org\/optimization-of-image-quality-and-diagnostic-accuracy-for-vascular-stenosis-in-computed-tomography-perfusion-reconstructed-cerebral-computed-tomography-angiography-using-deep-learning-reconstruction\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/clinicalimagingscience.org\/optimization-of-image-quality-and-diagnostic-accuracy-for-vascular-stenosis-in-computed-tomography-perfusion-reconstructed-cerebral-computed-tomography-angiography-using-deep-learning-reconstruction\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T06:50:42Z","timestamp":1773989442000},"score":1,"resource":{"primary":{"URL":"https:\/\/clinicalimagingscience.org\/optimization-of-image-quality-and-diagnostic-accuracy-for-vascular-stenosis-in-computed-tomography-perfusion-reconstructed-cerebral-computed-tomography-angiography-using-deep-learning-reconstruction\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,17]]},"references-count":35,"alternative-id":["10.25259\/JCIS_226_2025"],"URL":"https:\/\/doi.org\/10.25259\/jcis_226_2025","relation":{},"ISSN":["2156-5597","2156-7514"],"issn-type":[{"value":"2156-5597","type":"electronic"},{"value":"2156-7514","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3,17]]},"article-number":"12"}}