{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T08:11:53Z","timestamp":1788509513037,"version":"build-2803163510"},"reference-count":21,"publisher":"Scientific Scholar","content-domain":{"domain":["clinicalimagingscience.org"],"crossmark-restriction":true},"short-container-title":["JCIS"],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate image quality and diagnostic performance of deep learning-based virtual contrast-enhanced (VCE) images generated from photon-counting CT (PCCT) datasets.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>\n                      Forty consecutive patients who underwent contrast-enhanced PCCT were retrospectively included and divided into training (\n                      <jats:italic>n<\/jats:italic>\n                      = 20) and testing (\n                      <jats:italic>n<\/jats:italic>\n                      = 20) cohorts. A supervised U-Net-based convolutional neural network was trained to generate VCE images from virtual non-contrast inputs, using true contrast-enhanced (TC) images as the reference. Quantitative similarity was assessed using the structural similarity index measure (SSIM), mean absolute error (MAE), mean squared error (MSE), and peak signal-to-noise ratio (PSNR). Qualitative evaluation was performed independently by two radiologists using a 5-point Likert scale across thoracic and abdominal structures, with assessment of exact, \u00b11-point, and diagnostic agreement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Quantitative analysis demonstrated high similarity between VCE and TC images, with very high SSIM and PSNR values and low MAE, while MSE showed a right-skewed distribution. Qualitatively, VCE images were consistently rated lower than TC images. However, central thoracic vascular structures, cardiac chambers, and mediastinal lymph nodes were frequently rated as diagnostic (Likert \u22653) with high diagnostic agreement. In contrast, abdominal solid organs and vessels were often judged non-diagnostic, mainly due to heterogeneous enhancement and apparent contrast defects.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The synthesis of VCE images from PCCT datasets is feasible and shows excellent quantitative similarity to TC images, with promising results for thoracic applications but limited reliability for abdominal evaluation at this stage.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/jcis_99_2026","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T07:12:45Z","timestamp":1788505965000},"page":"34","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical feasibility and image quality assessment of deep learning-based virtual contrast enhancement from photon-counting computed tomography"],"prefix":"10.25259","volume":"16","author":[{"given":"Julien G.","family":"Cohen","sequence":"first","affiliation":[{"name":"Division of Radiology, Diagnostic Department, University Hospitals of Geneva, Geneva, Switzerland,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel Valentin","family":"Stadelmann","sequence":"additional","affiliation":[{"name":"Division of Radiology, Diagnostic Department, University Hospitals of Geneva, Geneva, Switzerland,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Leite-Arada","sequence":"additional","affiliation":[{"name":"Division of Radiology, Diagnostic Department, University Hospitals of Geneva, Geneva, Switzerland,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre-Alexandre","family":"Poletti","sequence":"additional","affiliation":[{"name":"Division of Radiology, Diagnostic Department, University Hospitals of Geneva, Geneva, Switzerland,"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"key":"10.25259\/JCIS_99_2026\/ref-1","doi-asserted-by":"publisher","first-page":"6798","DOI":"10.1007\/s00330-025-11675-1","article-title":"Hypersensitivity reactions to contrast media: Part 1 Management of immediate and non-immediate hypersensitivity reactions in adults Updated guidelines by the ESUR contrast media safety committee","volume":"35","author":"Van Der Molen","year":"2025","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_99_2026\/ref-2","doi-asserted-by":"publisher","first-page":"2845","DOI":"10.1007\/s00330-017-5246-5","article-title":"Post-contrast acute kidney injury-part 1: Definition, clinical features, incidence, role of contrast medium and risk factors: Recommendations for updated ESUR contrast medium safety committee guidelines","volume":"28","author":"Van Der Molen","year":"2018","journal-title":"Eur Radiol"},{"key":"10.25259\/JCIS_99_2026\/ref-3","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography--an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N Engl J Med"},{"key":"10.25259\/JCIS_99_2026\/ref-4","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1148\/radiol.2303021726","article-title":"Strategies for CT radiation dose optimization","volume":"230","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"10.25259\/JCIS_99_2026\/ref-5","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1097\/RLI.0000000000000980","article-title":"Technical basics and clinical benefits of photon-counting CT","volume":"58","author":"Flohr","year":"2023","journal-title":"Invest Radiol"},{"key":"10.25259\/JCIS_99_2026\/ref-6","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1148\/rg.2019180115","article-title":"Photon-counting detector CT: System design and clinical applications of an emerging technology","volume":"39","author":"Leng","year":"2019","journal-title":"Radiographics"},{"key":"10.25259\/JCIS_99_2026\/ref-7","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1097\/RCT.0000000000001562","article-title":"Photon-counting computed tomography versus energy-integrating dual-energy computed tomography: Virtual noncontrast image quality comparison","volume":"48","author":"Dane","year":"2024","journal-title":"J Comput Assist Tomogr"},{"key":"10.25259\/JCIS_99_2026\/ref-8","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1007\/978-3-319-24574-4_28","volume-title":"International Conference on Medical Image Computing and Computer-Assisted Intervention","author":"Ronneberger","year":"2015"},{"key":"10.25259\/JCIS_99_2026\/ref-9","first-page":"193","article-title":"Medical Imaging 2019: Biomedical Applications in Molecular Structural and Functional Imaging","author":"Stadelmann","year":"2019","journal-title":"United States: SPIE;"},{"key":"10.25259\/JCIS_99_2026\/ref-10","doi-asserted-by":"publisher","first-page":"20390","DOI":"10.1038\/s41598-021-99896-4","article-title":"The feasibility of deep learning-based synthetic contrast-enhanced CT from nonenhanced CT in emergency department patients with acute abdominal pain","volume":"11","author":"Kim","year":"2021","journal-title":"Sci Rep"},{"key":"10.25259\/JCIS_99_2026\/ref-11","doi-asserted-by":"publisher","first-page":"20403","DOI":"10.1038\/s41598-021-00058-3","article-title":"Generating synthetic contrast enhancement from non-contrast chest computed tomography using a generative adversarial network","volume":"11","author":"Choi","year":"2021","journal-title":"Sci Rep"},{"key":"10.25259\/JCIS_99_2026\/ref-12","doi-asserted-by":"publisher","first-page":"17635","DOI":"10.1038\/s41598-024-68705-z","article-title":"Clinical feasibility of deep learning based synthetic contrast enhanced abdominal CT in patients undergoing non enhanced CT scans","volume":"14","author":"Han","year":"2024","journal-title":"Sci Rep"},{"key":"10.25259\/JCIS_99_2026\/ref-13","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","article-title":"Photon-counting CT review","volume":"79","author":"Flohr","year":"2020","journal-title":"Phys Med"},{"key":"10.25259\/JCIS_99_2026\/ref-14","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1007\/978-3-319-46475-6_43","volume-title":"European Conference on Computer Vision","author":"Johnson","year":"2016"},{"key":"10.25259\/JCIS_99_2026\/ref-15","article-title":"Very Deep Convolutional Networks for Large-Scale Image Recognition [arXiv Preprint]","author":"Simonyan","year":"2014"},{"key":"10.25259\/JCIS_99_2026\/ref-16","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1109\/CVPR.2009.5206848","author":"Deng","year":"2009"},{"key":"10.25259\/JCIS_99_2026\/ref-17","author":"Kingma","year":"2014"},{"key":"10.25259\/JCIS_99_2026\/ref-18","doi-asserted-by":"publisher","first-page":"211","DOI":"10.2174\/1874434601711010211","article-title":"High agreement and high prevalence: The paradox of cohen's Kappa","volume":"11","author":"Zec","year":"2017","journal-title":"Open Nurs J"},{"key":"10.25259\/JCIS_99_2026\/ref-19","doi-asserted-by":"publisher","first-page":"102094","DOI":"10.1016\/j.compmedimag.2022.102094","article-title":"Virtual contrast enhancement for CT scans of abdomen and pelvis","volume":"100","author":"Liu","year":"2022","journal-title":"Comput Med Imaging Graph"},{"key":"10.25259\/JCIS_99_2026\/ref-20","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1038\/s41591-024-02850-w","article-title":"Heterogeneity and predictors of the effects of AI assistance on radiologists","volume":"30","author":"Yu","year":"2024","journal-title":"Nat Med"},{"key":"10.25259\/JCIS_99_2026\/ref-21","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1038\/s41746-024-01328-w","article-title":"Impact of human and artificial intelligence collaboration on workload reduction in medical image interpretation","volume":"7","author":"Chen","year":"2024","journal-title":"NPJ Digit Med"}],"container-title":["Journal of Clinical Imaging Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/clinicalimagingscience.org\/clinical-feasibility-and-image-quality-assessment-of-deep-learning-based-virtual-contrast-enhancement-from-photon-counting-computed-tomography\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/clinicalimagingscience.org\/clinical-feasibility-and-image-quality-assessment-of-deep-learning-based-virtual-contrast-enhancement-from-photon-counting-computed-tomography\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T07:12:46Z","timestamp":1788505966000},"score":1,"resource":{"primary":{"URL":"https:\/\/clinicalimagingscience.org\/clinical-feasibility-and-image-quality-assessment-of-deep-learning-based-virtual-contrast-enhancement-from-photon-counting-computed-tomography\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":21,"alternative-id":["10.25259\/JCIS_99_2026"],"URL":"https:\/\/doi.org\/10.25259\/jcis_99_2026","relation":{},"ISSN":["2156-5597","2156-7514"],"issn-type":[{"value":"2156-5597","type":"electronic"},{"value":"2156-7514","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9,4]]},"article-number":"34"}}