{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T17:24:14Z","timestamp":1794331454376,"version":"4.9.0"},"reference-count":40,"publisher":"Scientific Scholar","content-domain":{"domain":["ruralneuropractice.com"],"crossmark-restriction":true},"short-container-title":["JNRP"],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Objectives:<\/jats:title>\n<jats:p>Intracranial pressure (ICP) monitoring in patients with intracranial tumors undergoing craniotomy is usually done in perioperative period in intensive care unit. Invasive measurement of ICP, though considered as the gold standard, has its own limitations such as availability of expertise, equipment, and associated complications. Period of raised ICP in post-operative period may impact patient outcomes. Post-craniotomy computed tomography (CT) assessment is done routinely and may need to be repeated if indicated during post-operative stay. Utility of sonographic serial optic nerve sheath diameter (ONSD) assessment in post-operative monitoring of patients who have undergone elective craniotomy was explored in this study. The primary objective of the study was to measure the dynamic change in ONSD as compared to baseline pre-operative measurement in the first 3 postoperative days after elective craniotomy. The secondary objective of the study was to evaluate correlation between ONSD value with Glasgow Coma Scale (GCS) and post-operative CT findings.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Materials and Methods:<\/jats:title>\n<jats:p>In this prospective, observational, and cohort study, we studied adult patients undergoing craniotomy for intracranial tumors. GCS assessment and sonographic measurement of ONSD were done preoperatively, immediate post-operative period, and 12, 24, and 48 h after surgery. CT scan to detect raised ICP was done at 24 h post-operative. Correlation of ONSD with GCS at respective period and correlation of CT scan finding with respective ONSD assessment were evaluated.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Results:<\/jats:title>\n<jats:p>A total of 57 patients underwent elective craniotomy for intracranial tumors. Significant difference was observed in ONSD value depending on time of measurement perioperatively (\u03c7<jats:sup>2<\/jats:sup> = 78.9, <jats:italic>P<\/jats:italic> = 0.00). There was initial increase in the first 12 h followed by decrease in ONSD in the next 48 h. Negative correlation was observed between baseline ONSD and 12 h GCS (\u03c1 = \u22120.345, <jats:italic>P<\/jats:italic> = 0.013). There was significant change in GCS scores based on the status of ONSD (raised or normal) at 12 h after surgery (<jats:italic>P<\/jats:italic> = 0.014). Significant correlation between USG ONSD and CT ONSD was observed (\u03c1 = 0.928, <jats:italic>P<\/jats:italic> = 0.000). Optimal cutoff value of ONSD to detect raised ICP with reference to CT signs was 4.8 mm with 80% sensitivity and 95% specificity.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st4\">\n<jats:title>Conclusion:<\/jats:title>\n<jats:p>ONSD undergoes dynamic changes, correlates with CT scan, and has good diagnostic accuracy to detect raised ICP post-craniotomy for intracranial tumors. It may serve as a useful tool in monitoring in resource-limited setup.<\/jats:p>\n<\/jats:sec>","DOI":"10.25259\/jnrp-2022-3-37","type":"journal-article","created":{"date-parts":[[2022,12,2]],"date-time":"2022-12-02T09:46:30Z","timestamp":1669974390000},"page":"676-683","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Analysis of dynamic changes in optic nerve sheath diameter (ONSD) with ultrasound in post-craniotomy patients: Trends and correlation with computed tomography ONSD and Glasgow coma scale in post-operative period"],"prefix":"10.25259","volume":"13","author":[{"given":"Allan","family":"Benhur","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaiprakash","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunaina Tejpal","family":"Karna","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adesh","family":"Shrivastava","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saurabh","family":"Saigal","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India,"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vaishali Vasant","family":"Waindeskar","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India,"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2022,12,2]]},"reference":[{"key":"10.25259\/JNRP-2022-3-37\/ref-1","doi-asserted-by":"publisher","first-page":"540","DOI":"10.3171\/jns.1988.69.4.0540","article-title":"Intracranial pressure monitoring after elective intracranial surgery: A retrospective study of 514 consecutive patients","volume":"69","author":"Constantini","year":"1988","journal-title":"J Neurosurg"},{"key":"10.25259\/JNRP-2022-3-37\/ref-2","article-title":"Intracranial pressure monitoring in postoperative treatment of supratentorial and infratentorial gliomas","volume-title":"Chemotherapy of Gliomas","year":"1985"},{"key":"10.25259\/JNRP-2022-3-37\/ref-3","doi-asserted-by":"publisher","first-page":"E6","DOI":"10.3171\/2017.8.FOCUS17450","article-title":"Complications of invasive intracranial pressure monitoring devices in neurocritical care","volume":"43","author":"Tavakoli","year":"2017","journal-title":"Neurosurg Focus"},{"key":"10.25259\/JNRP-2022-3-37\/ref-4","doi-asserted-by":"publisher","author":"Marmarou","year":"1998","DOI":"10.1007\/978-3-7091-6475-4"},{"key":"10.25259\/JNRP-2022-3-37\/ref-5","doi-asserted-by":"publisher","first-page":"950393","DOI":"10.1155\/2012\/950393","article-title":"Intracranial pressure monitoring: Invasive versus non-invasive methods-a review","volume":"2012","author":"Raboel","year":"2012","journal-title":"Crit Care Res Pract"},{"key":"10.25259\/JNRP-2022-3-37\/ref-6","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1111\/jon.12691","article-title":"Quantification of optic nerve and sheath diameter by transorbital sonography: A systematic review and metanalysis","volume":"30","author":"Schroeder","year":"2020","journal-title":"J Neuroimaging"},{"key":"10.25259\/JNRP-2022-3-37\/ref-7","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1007\/s12028-011-9606-8","article-title":"Optic nerve ultrasound for the detection of raised intracranial pressure","volume":"15","author":"Rajajee","year":"2011","journal-title":"Neurocrit Care"},{"key":"10.25259\/JNRP-2022-3-37\/ref-8","doi-asserted-by":"publisher","first-page":"743","DOI":"10.3171\/2014.10.JNS141197","article-title":"Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure","volume":"123","author":"Maissan","year":"2015","journal-title":"J Neurosurg"},{"key":"10.25259\/JNRP-2022-3-37\/ref-9","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/978-94-009-3315-6_99","volume-title":"Documenta Ophthalmologica Proceedings Series","author":"Cennamo","year":"1987"},{"key":"10.25259\/JNRP-2022-3-37\/ref-10","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1111\/j.1553-2712.2007.00031.x","article-title":"Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure","volume":"15","author":"Kimberly","year":"2008","journal-title":"Acad Emerg Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-11","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: A systematic review and meta-analysis","volume":"37","author":"Dubourg","year":"2011","journal-title":"Intensive Care Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-12","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.ajem.2012.06.025","article-title":"Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure","volume":"31","author":"Amini","year":"2013","journal-title":"Am J Emerg Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-13","doi-asserted-by":"publisher","first-page":"217","DOI":"10.5811\/westjem.2013.9.16191","article-title":"Prospective analysis of single operator sonographic optic nerve sheath diameter measurement for diagnosis of elevated intracranial pressure","volume":"15","author":"Frumin","year":"2014","journal-title":"West J Emerg Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-14","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1177\/1460408615606752","article-title":"Transocular ultrasound measurement of the optic nerve sheath diameter can identify elevated intracranial pressure in trauma patients","volume":"18","author":"Nash","year":"2016","journal-title":"Trauma"},{"key":"10.25259\/JNRP-2022-3-37\/ref-15","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1186\/s12883-017-0964-5","article-title":"Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement","volume":"17","author":"Liu","year":"2017","journal-title":"BMC Neurol"},{"key":"10.25259\/JNRP-2022-3-37\/ref-16","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1007\/s00134-018-5305-7","article-title":"Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: A systematic review and meta-analysis","volume":"44","author":"Robba","year":"2018","journal-title":"Intensive Care Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-17","first-page":"683","article-title":"Correlation between ultrasonographic optic nerve sheath diameter and intracranial pressure","volume":"54","author":"Li","year":"2018","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"10.25259\/JNRP-2022-3-37\/ref-18","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1177\/0284185118776501","article-title":"Ultrasonographic optic nerve sheath diameter to detect increased intracranial pressure in adults: A meta-analysis","volume":"60","author":"Kim","year":"2019","journal-title":"Acta Radiol"},{"key":"10.25259\/JNRP-2022-3-37\/ref-19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/02688697.2019.1639618","article-title":"Ultrasonographic optic nerve sheath diameter correlation with ICP and accuracy as a tool for noninvasive surrogate ICP measurement in patients with decompressive craniotomy","volume":"133","author":"Wang","year":"2019","journal-title":"J Neurosurg"},{"key":"10.25259\/JNRP-2022-3-37\/ref-20","first-page":"151","article-title":"Pre-anaesthetic assessment of intracranial pressure using optic nerve sheath diameter in patients scheduled for elective tumour craniotomy","volume":"30","author":"Shafiq","year":"2018","journal-title":"J Ayub Med Coll Abbottabad"},{"key":"10.25259\/JNRP-2022-3-37\/ref-21","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/s12871-017-0333-3","article-title":"Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45 Trendelenburg position","volume":"17","author":"Blecha","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"10.25259\/JNRP-2022-3-37\/ref-22","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1093\/bja\/aew356","article-title":"Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive methods","volume":"117","author":"Robba","year":"2016","journal-title":"Br J Anaesth"},{"key":"10.25259\/JNRP-2022-3-37\/ref-23","doi-asserted-by":"publisher","first-page":"775","DOI":"10.4103\/0019-5049.191701","article-title":"Ultrasonographic optic nerve sheath diameter measurement in overweight parturient with intracranial tumour: Guiding choice of anaesthesia","volume":"60","author":"Riaz","year":"2016","journal-title":"Indian J Anaesth"},{"key":"10.25259\/JNRP-2022-3-37\/ref-24","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.jns.2015.12.032","article-title":"Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension","volume":"361","author":"Del Saz-Saucedo","year":"2016","journal-title":"J Neurol Sci"},{"key":"10.25259\/JNRP-2022-3-37\/ref-25","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1177\/1971400918789385","article-title":"Optic nerve sonographic examination to predict raised intracranial pressure in idiopathic intracranial hypertension: The cut-off points","volume":"31","author":"Kishk","year":"2018","journal-title":"Neuroradiol J"},{"key":"10.25259\/JNRP-2022-3-37\/ref-26","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1007\/s12028-009-9250-8","article-title":"Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage","volume":"11","author":"Moretti","year":"2009","journal-title":"Neurocrit Care"},{"key":"10.25259\/JNRP-2022-3-37\/ref-27","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.wneu.2015.10.015","article-title":"Transorbital ultrasonographic measurement of optic nerve sheath diameter for intracranial Midline shift in patients with head trauma","volume":"85","author":"Kazdal","year":"2016","journal-title":"World Neurosurg"},{"key":"10.25259\/JNRP-2022-3-37\/ref-28","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.ajem.2016.09.044","article-title":"Optic nerve sheath diameter measurement: A means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients","volume":"35","author":"Raffiz","year":"2017","journal-title":"Am J Emerg Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-29","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1016\/j.neuchi.2017.06.001","article-title":"Role of serial ultrasonic optic nerve sheath diameter monitoring in head injury","volume":"63","author":"Thotakura","year":"2017","journal-title":"Neurochirurgie"},{"key":"10.25259\/JNRP-2022-3-37\/ref-30","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1136\/bjsm.2007.045286","article-title":"Optic nerve sheath diameter, intracranial pressure and acute mountain sickness on Mount Everest: A longitudinal cohort study","volume":"42","author":"Sutherland","year":"2008","journal-title":"Br J Sports Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-31","first-page":"45","article-title":"Ultrasound measurement of ocular nerve sheath diameter can be used for the estimation of cerebral oedema","volume":"17","author":"Karellas","year":"2014","journal-title":"Balkan Mil Med Rev"},{"key":"10.25259\/JNRP-2022-3-37\/ref-32","doi-asserted-by":"publisher","first-page":"P457","DOI":"10.1186\/cc14537","article-title":"Optic nerve sheath diameter by bedside ultrasound is a reliable screening test for cerebral edema in the comatose ICU patient","volume":"19","author":"Mohamed","year":"2015","journal-title":"Crit Care"},{"key":"10.25259\/JNRP-2022-3-37\/ref-33","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1111\/jon.12233","article-title":"Transorbital ultrasonographic measurement of optic nerve sheath diameter in brain death: Transorbital ultrasonographic measurement of ONSD in BD","volume":"25","author":"Topcuoglu","year":"2015","journal-title":"J Neuroimaging"},{"key":"10.25259\/JNRP-2022-3-37\/ref-34","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1186\/s12883-018-1202-5","article-title":"Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy","volume":"18","author":"Gao","year":"2018","journal-title":"BMC Neurol"},{"key":"10.25259\/JNRP-2022-3-37\/ref-35","first-page":"1","article-title":"Transorbital ultrasound measurement of optic nerve sheath diameter. A novel technique for measuring intra-cranial pressure in neurosurgical intensive care setup","volume":"10","author":"Majhi","year":"2020","journal-title":"Indian J Appl Res"},{"key":"10.25259\/JNRP-2022-3-37\/ref-36","doi-asserted-by":"publisher","first-page":"1285","DOI":"10.7863\/ultra.34.7.1285","article-title":"Sonography of the optic nerve sheath diameter for detection of raised intracranial pressure compared to computed tomography: A systematic review and meta-analysis","volume":"34","author":"Ohle","year":"2015","journal-title":"J Ultrasound Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-37","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1197\/aemj.10.4.376","article-title":"Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath","volume":"10","author":"Blaivas","year":"2003","journal-title":"Acad Emerg Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-38","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1097\/MEJ.0b013e32835105c8","article-title":"Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency department","volume":"20","author":"Qayyum","year":"2013","journal-title":"Eur J Emerg Med"},{"key":"10.25259\/JNRP-2022-3-37\/ref-39","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1136\/emj.2009.087353","article-title":"Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure","volume":"28","author":"Major","year":"2011","journal-title":"Emerg Med J"},{"key":"10.25259\/JNRP-2022-3-37\/ref-40","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1016\/j.injury.2007.09.029","article-title":"Utility of optic nerve ultrasonography in head injury","volume":"39","author":"Goel","year":"2008","journal-title":"Injury"}],"container-title":["Journal of Neurosciences in Rural Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/ruralneuropractice.com\/analysis-of-dynamic-changes-in-optic-nerve-sheath-diameter-onsd-with-ultrasound-in-post-craniotomy-patients-trends-and-correlation-with-computed-tomography-onsd-and-glasgow-coma-scale-in-post-opera\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/ruralneuropractice.com\/analysis-of-dynamic-changes-in-optic-nerve-sheath-diameter-onsd-with-ultrasound-in-post-craniotomy-patients-trends-and-correlation-with-computed-tomography-onsd-and-glasgow-coma-scale-in-post-opera\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,20]],"date-time":"2023-03-20T12:31:41Z","timestamp":1679315501000},"score":1,"resource":{"primary":{"URL":"https:\/\/ruralneuropractice.com\/analysis-of-dynamic-changes-in-optic-nerve-sheath-diameter-onsd-with-ultrasound-in-post-craniotomy-patients-trends-and-correlation-with-computed-tomography-onsd-and-glasgow-coma-scale-in-post-opera\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,2]]},"references-count":40,"alternative-id":["10.25259\/JNRP-2022-3-37"],"URL":"https:\/\/doi.org\/10.25259\/jnrp-2022-3-37","relation":{},"ISSN":["0976-3155","0976-3147"],"issn-type":[{"value":"0976-3155","type":"electronic"},{"value":"0976-3147","type":"print"}],"subject":[],"published":{"date-parts":[[2022,12,2]]},"article-number":"676"}}