{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T10:44:17Z","timestamp":1776509057392,"version":"3.51.2"},"reference-count":8,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Background: <\/jats:title>\n<jats:p>The ultrasonic surgical aspirator is widely used in intracranial tumor resection as this instrument is considered safe. The advantage of an ultrasonic surgical aspirator is that it does not damage vessels or nerves close to the tumor. Therefore, limited information exists regarding intraoperative arterial injury by the ultrasonic surgical aspirator.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Case Description: <\/jats:title>\n<jats:p>We report two cases. The first case was a 30-year-old woman who underwent surgery for a recurrent craniopharyngioma, and the second was a 50-year-old man who underwent surgery for a meningioma. A craniopharyngioma encased the basilar artery in the former case, and the superior cerebellar artery was encased by a meningioma in the latter. An ultrasonic surgical aspirator was used to resect the tumors in two cases. During surgery, the arteries involved in the tumors were unintentionally injured using an ultrasonic surgical aspirator. Intraoperative hemostasis was achieved for the bleeding from the injured arteries. However, postoperative digital cerebral angiography revealed pseudoaneurysms in the injured arteries. A subarachnoid hemorrhage occurred in the first case. The pseudoaneurysms were managed using endovascular embolization.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Conclusion: <\/jats:title>\n<jats:p>Intraoperative arterial injury can occur with the application of an ultrasonic surgical aspirator. Neurosurgeons should be cautious when using ultrasonic surgical aspirators to avoid damaging the arteries involved with the tumor.<\/jats:p>\n<\/jats:sec>","DOI":"10.25259\/sni_1015_2023","type":"journal-article","created":{"date-parts":[[2024,7,19]],"date-time":"2024-07-19T04:04:49Z","timestamp":1721361889000},"page":"251","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Two reports of iatrogenic pseudoaneurysms intraoperatively induced by an ultrasonic surgical aspirator: A rare intraoperative complication"],"prefix":"10.25259","volume":"15","author":[{"given":"Hirokuni","family":"Hashikata","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasunori","family":"Nagai","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gen","family":"Futamura","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naokado","family":"Ikeda","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masanori","family":"Goto","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Maki","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Hikone Chuo Hospital, Hikone, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Toda","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Iwasaki","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Medical Research Institute Kitano Hospital, PIIF Tazuke-Kofukai, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2024,7,19]]},"reference":[{"key":"10.25259\/SNI_1015_2023\/ref-1","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1227\/00006123-197805000-00010","article-title":"Preliminary experience with ultrasonic aspiration in neurosurgery","volume":"2","author":"Flamm","year":"1978","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_1015_2023\/ref-2","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1227\/00006123-198904000-00025","article-title":"Experience with the ultrasonic surgical aspirator in a cavernous hemangioma of the cavernous sinus","volume":"24","author":"Kudo","year":"1989","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_1015_2023\/ref-3","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1159\/000354036","article-title":"Methods of haemostasis during liver resection--a UK national survey","volume":"30","author":"Lochan","year":"2013","journal-title":"Dig Surg"},{"key":"10.25259\/SNI_1015_2023\/ref-4","doi-asserted-by":"crossref","first-page":"381","DOI":"10.3322\/caac.21693","article-title":"Brain and other central nervous system tumor statistics, 2021","volume":"71","author":"Miller","year":"2021","journal-title":"CA Cancer J Clin"},{"key":"10.25259\/SNI_1015_2023\/ref-5","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1016\/j.avsg.2020.05.021","article-title":"Efficacy of the decalcification of heavily calcified femoral bifurcation lesions using a cavitron ultrasonic surgical aspirator","volume":"69","author":"Miyake","year":"2020","journal-title":"Ann Vasc Surg"},{"key":"10.25259\/SNI_1015_2023\/ref-6","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/0090-3019(89)90180-8","article-title":"Interface between the meningioma and the brain","volume":"32","author":"Nakasu","year":"1989","journal-title":"Surg Neurol"},{"key":"10.25259\/SNI_1015_2023\/ref-7","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/BF01808918","article-title":"Suction in neurosurgery","volume":"55","author":"V\u00e4llfors","year":"1980","journal-title":"Acta Neurochir (Wien)"},{"key":"10.25259\/SNI_1015_2023\/ref-8","doi-asserted-by":"crossref","first-page":"2015","DOI":"10.1007\/s00345-015-1569-5","article-title":"Partial nephrectomy driven by cavitron ultrasonic surgical aspirator under zero ischemia: A pilot study","volume":"33","author":"Weibl","year":"2015","journal-title":"World J Urol"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/two-reports-of-iatrogenic-pseudoaneurysms-intraoperatively-induced-by-an-ultrasonic-surgical-aspirator-a-rare-intraoperative-complication\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/two-reports-of-iatrogenic-pseudoaneurysms-intraoperatively-induced-by-an-ultrasonic-surgical-aspirator-a-rare-intraoperative-complication\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,19]],"date-time":"2024-07-19T04:04:59Z","timestamp":1721361899000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/two-reports-of-iatrogenic-pseudoaneurysms-intraoperatively-induced-by-an-ultrasonic-surgical-aspirator-a-rare-intraoperative-complication\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,19]]},"references-count":8,"alternative-id":["10.25259\/SNI_1015_2023"],"URL":"https:\/\/doi.org\/10.25259\/sni_1015_2023","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2024,7,19]]},"article-number":"251"}}