{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T21:39:17Z","timestamp":1779399557951,"version":"3.53.1"},"reference-count":11,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Spinal cord stimulation (SCS) is a widely used therapy for chronic neuropathic pain. Although generally safe, rare complications such as spinal cord injury can occur. Most cases present within days to weeks of implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Case Description:<\/jats:title>\n                    <jats:p>A 48-year-old female with chronic back pain was treated with SCS placement at T9\u2013T10 in 2008. Seventeen years later, she presented with the sudden onset of paraparesis (greater on left), a T10 sensory loss to pin appreciation, and bowel incontinence. Her examination was consistent with a Brown-Sequard like syndrome. Once the SCS was removed, the magnetic resonance imaging (MRI) showed significant residual cord compression due to an epidural mass extending from T8 to T10; causing hyperintense T2 signal changes in the cord. Following a T8\u2013T10 laminectomy with resection of the fibrotic tissue, the patient improved regarding her gait but still had residual numbness in both lower extremities. The postoperative MRI 4 weeks later revealed no residual stenosis or spinal cord compression, but faint T2 signal changes within the cord remained.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This case highlights how a SCS resulted in the late onset (i.e. 17 years later) of a Brown-S\u00e9quard like syndrome attributed to placement of a SCS.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/sni_1077_2025","type":"journal-article","created":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T07:29:53Z","timestamp":1763710193000},"page":"493","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Sudden onset Brown-Sequard-like symptoms due to fibrotic scar tissue formation around spinal cord stimulator electrode with associated spinal cord compression"],"prefix":"10.25259","volume":"16","author":[{"given":"Rylie","family":"Wackerly","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Sam Houston State University College of Osteopathic Medicine, Conroe, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor","family":"Castano","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Texas at Austin Dell Medical School, Austin, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent Y.","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, University of Texas at Austin Dell Medical School, Austin, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2025,11,21]]},"reference":[{"key":"10.25259\/SNI_1077_2025\/ref-1","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1097\/PHM.0000000000000411","article-title":"Progressive paraplegia from spinal cord stimulator lead fibrotic encapsulation: A case report","volume":"95","author":"Benfield","year":"2016","journal-title":"Am J Phys Med Rehabil"},{"key":"10.25259\/SNI_1077_2025\/ref-2","doi-asserted-by":"crossref","first-page":"598","DOI":"10.3171\/2012.9.SPINE12334","article-title":"Dorsal myelopathy secondary to epidural fibrous scar tissue around a spinal cord stimulation electrode","volume":"17","author":"Cicuendez","year":"2012","journal-title":"J Neurosurg Spine"},{"key":"10.25259\/SNI_1077_2025\/ref-3","doi-asserted-by":"crossref","first-page":"409","DOI":"10.3171\/2009.10.SPINE09193","article-title":"Cervical cord compression due to delayed scarring around epidural electrodes used in spinal cord stimulation","volume":"12","author":"Dam-Hieu","year":"2010","journal-title":"J Neurosurg Spine"},{"key":"10.25259\/SNI_1077_2025\/ref-4","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1111\/ner.12282","article-title":"Reversible late thoracic myelopathy and neurostimulation tolerance caused by fibrous scar tissue formation around the spinal cord stimulation electrode","volume":"18","author":"Fransen","year":"2015","journal-title":"Neuromodulation"},{"key":"10.25259\/SNI_1077_2025\/ref-5","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1007\/s11916-023-01190-7","article-title":"Complications of spinal cord stimulator trials and implants: A review","volume":"27","author":"Garg","year":"2023","journal-title":"Curr Pain Headache Rep"},{"key":"10.25259\/SNI_1077_2025\/ref-6","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1136\/rapm-2021-103307","article-title":"Evaluating the incidence of spinal cord injury after spinal cord stimulator implant: An updated retrospective review","volume":"47","author":"Hussain","year":"2022","journal-title":"Reg Anesth Pain Med"},{"key":"10.25259\/SNI_1077_2025\/ref-7","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1097\/PTS.0000000000000971","article-title":"Spinal cord stimulators: An analysis of the adverse events reported to the Australian therapeutic goods administration","volume":"18","author":"Jones","year":"2022","journal-title":"J Patient Saf"},{"key":"10.25259\/SNI_1077_2025\/ref-8","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1111\/j.1533-2500.2010.00407.x","article-title":"Retrospective review of 707 cases of spinal cord stimulation: Indications and complications","volume":"11","author":"Mekhail","year":"2011","journal-title":"Pain Pract"},{"key":"10.25259\/SNI_1077_2025\/ref-9","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1038\/s41394-022-00550-6","article-title":"Spinal cord stimulator medullary compression-a very rare SCS complication and surgical treatment","volume":"8","author":"Pallotta","year":"2022","journal-title":"Spinal Cord Ser Cases"},{"key":"10.25259\/SNI_1077_2025\/ref-10","article-title":"Brown-S\u00e9quard syndrome","volume-title":"StatPearls","author":"Shams","year":"2025"},{"key":"10.25259\/SNI_1077_2025\/ref-11","first-page":"137","article-title":"A rare case of spinal cord injury after uncomplicated implantation of a spinal cord stimulator: A case report","volume":"9","author":"Wen","year":"2025","journal-title":"Pain Med Case Rep"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/sudden-onset-brown-sequard-like-symptoms-due-to-fibrotic-scar-tissue-formation-around-spinal-cord-stimulator-electrode-with-associated-spinal-cord-compression\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/sudden-onset-brown-sequard-like-symptoms-due-to-fibrotic-scar-tissue-formation-around-spinal-cord-stimulator-electrode-with-associated-spinal-cord-compression\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T07:29:55Z","timestamp":1763710195000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/sudden-onset-brown-sequard-like-symptoms-due-to-fibrotic-scar-tissue-formation-around-spinal-cord-stimulator-electrode-with-associated-spinal-cord-compression\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,21]]},"references-count":11,"alternative-id":["10.25259\/SNI_1077_2025"],"URL":"https:\/\/doi.org\/10.25259\/sni_1077_2025","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2025,11,21]]},"article-number":"493"}}