{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T13:02:32Z","timestamp":1780923752334,"version":"3.54.1"},"reference-count":19,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Background: <\/jats:title>\n<jats:p>Durable occlusion after endovascular coiling can be compromised by recanalization, underscoring the need for accurate cerebral aneurysm assessment. Precise volume measurement not only informs treatment decisions and detects subtle aneurysm growth but also refines calculations of packing density, historically linked to occlusion success. This study compares three volume-measurement approaches-traditional two-dimensional (2D) estimation, a semi-automated three-dimensional (3D) technique, and an artificial intelligence (AI)-based 3D method.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Methods: <\/jats:title>\n<jats:p>In this retrospective analysis, 24 aneurysms were assessed using 3D rotational angiography. Manual segmentation by three specialists using ITK-SNAP or mimics served as the reference standard. These results were compared with volumes from a semi-automated 3D platform (Philips Advanced Visualization Workspace), an AI-based tool (RapidAI for Aneurysm), and traditional 2D estimations. Agreement with the reference standard was quantified through Passing-Bablok regression slopes and mean biases.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Results: <\/jats:title>\n<jats:p>Passing-Bablok slopes for the 2D, Philips, and RapidAI methods were 0.83, 0.87, and 0.94, respectively, while mean biases were \u201324.7 mm<jats:sup>3<\/jats:sup> (2D), \u201319.5 mm<jats:sup>3<\/jats:sup> (Philips), and \u201314.5 mm<jats:sup>3<\/jats:sup> (RapidAI). RapidAI demonstrated the strongest correlation with the reference standard, whereas 2D estimations showed the largest discrepancy. The semi-automated 3D method exhibited intermediate accuracy, potentially influenced by the clinician input required for segmentation.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st4\">\n<jats:title>Conclusion: <\/jats:title>\n<jats:p>All methods underestimated aneurysm volumes compared to the reference standard, suggesting that inaccurate volume measurements may mask early aneurysm growth. Among the techniques assessed, the AI-based approach provided the closest agreement with the reference, indicating that improved volumetric methods-particularly AI-driven ones-can enhance early detection of aneurysm expansion, guide treatment decisions, and help establish more reliable follow-up strategies for both treated and conservatively managed aneurysms.<\/jats:p>\n<\/jats:sec>","DOI":"10.25259\/sni_1118_2024","type":"journal-article","created":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T09:52:51Z","timestamp":1748598771000},"page":"213","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Enhancing precision in aneurysm volume measurement: A comparative study of techniques including an artificial intelligence-based method for endovascular coiling"],"prefix":"10.25259","volume":"16","author":[{"given":"Rafael Trindade","family":"Tatit","sequence":"first","affiliation":[{"name":"Interventional Neuroradiology, Hospital Israelita Albert Einstein, S\u00e3o Paulo, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos Eduardo","family":"Baccin","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology, Hospital Israelita Albert Einstein, S\u00e3o Paulo, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priya","family":"Nair","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering (2016-2017), Arizona State University, Tempe, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuel O.","family":"Mensah","sequence":"additional","affiliation":[{"name":"Neurosurgery Division, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James Ryan","family":"Mason","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seena","family":"Dehkharghani","sequence":"additional","affiliation":[{"name":"Department of Radiology, NYU Langone Health, New York, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen","family":"Copeland","sequence":"additional","affiliation":[{"name":"Boulder Statistics LLC, Boulder, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher S.","family":"Ogilvy","sequence":"additional","affiliation":[{"name":"Neurosurgery Division, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2025,5,30]]},"reference":[{"key":"10.25259\/SNI_1118_2024\/ref-1","doi-asserted-by":"crossref","first-page":"19609","DOI":"10.1038\/s41598-024-70453-z","article-title":"Aneurysm growth evaluation and detection: A computer-assisted follow-up MRA analysis","volume":"14","author":"Bizjak \u017d","year":"2024","journal-title":"Sci Rep"},{"key":"10.25259\/SNI_1118_2024\/ref-2","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.3171\/2018.11.JNS181814","article-title":"Unruptured intracranial aneurysm growth trajectory: Occurrence and rate of enlargement in 520 longitudinally followed cases","volume":"132","author":"Chien","year":"2020","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1118_2024\/ref-3","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1179\/1743132813Y.0000000316","article-title":"Comparison between routine cylindrical cerebral aneurysm volume approximation and three-dimensional volume measurements in experimental aneurysms","volume":"36","author":"Erhardt","year":"2014","journal-title":"Neurol Res"},{"key":"10.25259\/SNI_1118_2024\/ref-4","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1136\/neurintsurg-2017-013311","article-title":"Voxel based analysis of recurrence dynamics in intracranial aneurysms after coiling","volume":"10","author":"Ernst","year":"2018","journal-title":"J Neurointerv Surg"},{"key":"10.25259\/SNI_1118_2024\/ref-5","doi-asserted-by":"crossref","first-page":"20210538","DOI":"10.1259\/bjr.20210538","article-title":"Comprehensive review of the recent advances in devices for endovascular treatment of complex brain aneurysms","volume":"95","author":"Fatania","year":"2022","journal-title":"Br J Radiol"},{"key":"10.25259\/SNI_1118_2024\/ref-6","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1136\/jnnp-2016-313584","article-title":"Unruptured intracranial aneurysm follow-up and treatment after morphological change is safe: Observational study and systematic review","volume":"87","author":"Gondar","year":"2016","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"10.25259\/SNI_1118_2024\/ref-7","doi-asserted-by":"crossref","first-page":"15910199231155288","DOI":"10.1177\/15910199231155288","article-title":"Packing density and the angiographic results of coil embolization of intracranial aneurysms: A systematic review and meta-analysis","volume":"12","author":"Hassankhani","year":"2023","journal-title":"Interv Neuroradiol"},{"key":"10.25259\/SNI_1118_2024\/ref-8","first-page":"e314","article-title":"2023 Guideline for the management of patients with aneurysmal subarachnoid hemorrhage: A guideline from the American heart association\/American stroke association","volume":"54","author":"Hoh","year":"2023","journal-title":"Stroke"},{"key":"10.25259\/SNI_1118_2024\/ref-9","doi-asserted-by":"crossref","first-page":"2536","DOI":"10.1161\/01.STR.0000034708.66191.7D","article-title":"Recommendations for the endovascular treatment of intracranial aneurysms: A statement for healthcare professionals from the committee on cerebrovascular imaging of the American heart association council on cardiovascular radiology","volume":"33","author":"Johnston","year":"2002","journal-title":"Stroke"},{"key":"10.25259\/SNI_1118_2024\/ref-10","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.3174\/ajnr.A7190","article-title":"A volumetric metric for monitoring intracranial aneurysms: Repeatability and growth criteria in a longitudinal MR imaging study","volume":"42","author":"Liu","year":"2021","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/SNI_1118_2024\/ref-11","doi-asserted-by":"crossref","first-page":"875","DOI":"10.3174\/ajnr.A5631","article-title":"Management of small unruptured intracranial aneurysms: A survey of neuroradiologists","volume":"39","author":"Malhotra","year":"2018","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/SNI_1118_2024\/ref-12","doi-asserted-by":"crossref","first-page":"7038","DOI":"10.1002\/mp.15846","article-title":"A deep learning-based automatic system for intracranial aneurysms diagnosis on three-dimensional digital subtraction angiographic images","volume":"49","author":"Ou","year":"2022","journal-title":"Med Phys"},{"key":"10.25259\/SNI_1118_2024\/ref-13","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1136\/neurintsurg-2020-017012","article-title":"Immediate post-operative aneurysm occlusion after endovascular treatment of intracranial aneurysms with coiling or balloon-assisted coiling in a prospective multicenter cohort of 1189 patients: Analysis of recanalization after endovascular treatment of intracranial aneurysm (ARETA) study","volume":"13","author":"Pierot","year":"2021","journal-title":"J Neurointerv Surg"},{"key":"10.25259\/SNI_1118_2024\/ref-14","first-page":"839","article-title":"Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms","volume":"27","author":"Piotin","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/SNI_1118_2024\/ref-15","doi-asserted-by":"crossref","first-page":"16080","DOI":"10.1038\/s41598-024-65825-4","article-title":"Assessing accuracy and consistency in intracranial aneurysm sizing: Human expertise vs. Artificial intelligence","volume":"14","author":"Planinc","year":"2024","journal-title":"Sci Rep"},{"key":"10.25259\/SNI_1118_2024\/ref-16","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1136\/jnis-2022-019339","article-title":"Artificial intelligence aneurysm measurement tool finds growth in all aneurysms that ruptured during conservative management","volume":"15","author":"Sahlein","year":"2023","journal-title":"J Neurointerv Surg"},{"key":"10.25259\/SNI_1118_2024\/ref-17","doi-asserted-by":"crossref","first-page":"721","DOI":"10.3174\/ajnr.A3777","article-title":"Validation and initial application of a semiautomatic aneurysm measurement software: A tool for assessing volumetric packing attenuation","volume":"35","author":"Takao","year":"2014","journal-title":"Am J Neuroradiol"},{"key":"10.25259\/SNI_1118_2024\/ref-18","doi-asserted-by":"crossref","first-page":"2368","DOI":"10.1161\/STR.0000000000000070","article-title":"Guidelines for the management of patients with un ruptured intracranial aneurysms: A guideline for healthcare professionals from the American heart association\/American stroke association","volume":"46","author":"Thompson","year":"2015","journal-title":"Stroke"},{"key":"10.25259\/SNI_1118_2024\/ref-19","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1148\/radiol.13121188","article-title":"Natural history of asymptomatic unruptured cerebral aneurysms evaluated at CT angiography: Growth and rupture incidence and correlation with epidemiologic risk factors","volume":"269","author":"Villablanca","year":"2013","journal-title":"Radiology"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/enhancing-precision-in-aneurysm-volume-measurement-a-comparative-study-of-techniques-including-an-artificial-intelligence-based-method-for-endovascular-coiling\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/enhancing-precision-in-aneurysm-volume-measurement-a-comparative-study-of-techniques-including-an-artificial-intelligence-based-method-for-endovascular-coiling\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T09:52:54Z","timestamp":1748598774000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/enhancing-precision-in-aneurysm-volume-measurement-a-comparative-study-of-techniques-including-an-artificial-intelligence-based-method-for-endovascular-coiling\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":19,"alternative-id":["10.25259\/SNI_1118_2024"],"URL":"https:\/\/doi.org\/10.25259\/sni_1118_2024","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5,30]]},"article-number":"213"}}