{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T07:07:18Z","timestamp":1779433638990,"version":"3.53.1"},"reference-count":33,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Ventricular puncture is crucial in hydrocephalus management, especially in shunt surgery, where accurate catheter placement is essential for shunt survival. Despite the high malposition rate associated with freehand insertion, image-guided techniques remain underutilized. The anterior approach predominates globally, though debate continues over the merits of anterior versus posterior routes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We retrospectively analyzed 106 anterior approach catheter insertions in hydrocephalus patients: neonates\/infants (&lt;1 year), children (1\u201315 years), and adults (60\u201365 years). Using postoperative computed tomography scans, we assessed catheter placement accuracy, cranial inclination at the puncture site, and trajectory deviation. Proper placement was defined as catheter tips located in the ipsilateral frontal horn or third ventricle.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Accurate placement was achieved in 76.4% of cases. Misplacement rates were highest in neonates\/ infants (39.3%), significantly exceeding those in children (7.7%) and adults (4.2%) (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.01). Logistic regression identified younger age and greater cranial inclination (&gt;37.2\u00b0) as key predictors of misplacement. Deviations from the ideal trajectory exceeding 12.9\u00b0 (particularly coronal deviations &gt;12.1\u00b0) were associated with increased misplacement and reduced shunt survival.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Misplacement rates are significantly higher in neonates\/infants, primarily due to anatomical differences. Image-guided techniques are recommended to improve catheter placement and shunt outcomes, particularly in younger patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/sni_1398_2025","type":"journal-article","created":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T06:29:59Z","timestamp":1779431399000},"page":"300","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Predominance of ventricular catheter misplacement with anterior approach in neonates and infants"],"prefix":"10.25259","volume":"17","author":[{"given":"Hiroyuki","family":"Katano","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Nagoya City University, Nagoya, Japan"},{"name":"Department of Medical Informatics, Nagoya City University, Nagoya, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoyasu","family":"Yamanaka","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nagoya City University, Nagoya, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeki","family":"Yamada","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nagoya City University, Nagoya, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuhito","family":"Mase","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Nagoya City University, Nagoya, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2026,5,22]]},"reference":[{"key":"10.25259\/SNI_1398_2025\/ref-1","doi-asserted-by":"crossref","first-page":"883","DOI":"10.3171\/jns.1988.69.6.0883","article-title":"Function of parietal and frontal shunts in childhood hydrocephalus","volume":"69","author":"Albright","year":"1988","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-2","first-page":"84","article-title":"Intraoperative uses of ultrasound in the pediatric neurosurgical patient","volume":"18","author":"Babcock","year":"1992","journal-title":"Pediatr Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-3","first-page":"287","article-title":"A prospective, randomized study of shunt function and infections as a function of shunt placement","volume":"16","author":"Bierbrauer","year":"1990","journal-title":"Pediatr Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-4","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1007\/s00701-020-04549-6","article-title":"Free-hand stereotactic ventricular catheter insertion technique based on radio-anatomical landmarks. How I do it","volume":"163","author":"Bruneau","year":"2021","journal-title":"Acta Neurochir (Wien)"},{"key":"10.25259\/SNI_1398_2025\/ref-5","doi-asserted-by":"crossref","first-page":"1418","DOI":"10.3171\/2024.2.JNS232978","article-title":"Effect of cranial entry site on the rate of proximal catheter misplacement in ventriculoperitoneal shunt insertion","volume":"141","author":"Ebel","year":"2024","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-6","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1007\/s00381-022-05807-x","article-title":"Pediatric ventriculoperitoneal shunt: A comparative study between anterior fontanel ultrasound-guided versus conventional cranial end insertion","volume":"39","author":"Elmesallamy","year":"2023","journal-title":"Childs Nerv Syst"},{"key":"10.25259\/SNI_1398_2025\/ref-7","doi-asserted-by":"crossref","first-page":"24","DOI":"10.3171\/2014.7.PEDS14323","article-title":"Pediatric hydrocephalus: Systematic literature review and evidence-based guidelines. Part 3: Endoscopic computer-assisted electromagnetic navigation and ultrasonography as technical adjuvants for shunt placement","volume":"14","author":"Flannery","year":"2014","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_1398_2025\/ref-8","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1002\/jcu.1870160606","article-title":"Detection of open spina bifida by the lemon sign: Pathologic correlation","volume":"16","author":"Gabbe","year":"1988","journal-title":"J Clin Ultrasound"},{"key":"10.25259\/SNI_1398_2025\/ref-9","doi-asserted-by":"crossref","first-page":"88","DOI":"10.3171\/JNS\/2008\/108\/01\/0088","article-title":"Accuracy of the freehand pass technique for ventriculostomy catheter placement: Retrospective assessment using computed tomography scans","volume":"108","author":"Huyette","year":"2008","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-11","doi-asserted-by":"crossref","first-page":"150","DOI":"10.3340\/jkns.2013.53.3.150","article-title":"Effect of electromagnetic navigated ventriculoperitoneal shunt placement on failure rates","volume":"53","author":"Jung","year":"2013","journal-title":"J Korean Neurosurg Soc"},{"key":"10.25259\/SNI_1398_2025\/ref-12","doi-asserted-by":"crossref","first-page":"284","DOI":"10.3171\/jns.2003.98.2.0284","article-title":"Lack of benefit of endoscopic ventriculoperitoneal shunt insertion: A multicenter randomized trial","volume":"98","author":"Kestle","year":"2003","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-13","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1055\/s-2000-11376","article-title":"Virtual placement of frontal ventricular catheters using frameless neuronavigation: An \u201cunbloody training\u201d for young neurosurgeons","volume":"43","author":"Krombach","year":"2000","journal-title":"Minim Invasive Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-14","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1111\/1471-0528.16496","article-title":"Cranial findings detected by second-trimester ultrasound in fetuses with myelomeningocele: A systematic review","volume":"128","author":"Kunpalin","year":"2021","journal-title":"BJOG"},{"key":"10.25259\/SNI_1398_2025\/ref-15","doi-asserted-by":"crossref","first-page":"930","DOI":"10.3171\/JNS\/2008\/108\/5\/0930","article-title":"Ventricular catheter trajectories from traditional shunt approaches: A morphometric study in adults with hydrocephalus","volume":"108","author":"Lind","year":"2008","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-16","doi-asserted-by":"crossref","first-page":"e10","DOI":"10.1016\/j.wneu.2022.05.057","article-title":"Anterior versus posterior ventricular catheter placement in pediatric patients: A systematic review and meta-analysis","volume":"167","author":"Naik","year":"2022","journal-title":"World Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-17","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s00381-008-0709-2","article-title":"Shortening of ventricular shunt catheter associated with cranial growth: Effect of the frontal and parieto-occipital access route on long-term shunt patency","volume":"25","author":"Nakahara","year":"2009","journal-title":"Childs Nerv Syst"},{"key":"10.25259\/SNI_1398_2025\/ref-18","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1227\/NEU.0000000000000849","article-title":"Image guidance in ventricular cerebrospinal fluid shunt catheter placement: A systematic review and meta-analysis","volume":"77","author":"Nesvick","year":"2015","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_1398_2025\/ref-19","doi-asserted-by":"crossref","first-page":"750","DOI":"10.3171\/jns.1994.80.4.0750","article-title":"Accurate placement of coronal ventricular catheter using stereotactic coordinate-guided free-hand passage. Technical note","volume":"80","author":"Pang","year":"1994","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-20","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.3171\/2016.11.JNS161765","article-title":"Revisiting the rules for freehand ventriculostomy: A virtual reality analysis","volume":"128","author":"Raabe","year":"2018","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-21","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.wneu.2013.01.096","article-title":"Long-term outcomes of ventriculoperitoneal shunt surgery in patients with hydrocephalus","volume":"81","author":"Reddy","year":"2014","journal-title":"World Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-22","doi-asserted-by":"crossref","first-page":"353","DOI":"10.2176\/nmc.44.353","article-title":"Manual occipital ventricular puncture for cerebrospinal fluid shunt surgery: Can aiming be standardized?","volume":"44","author":"Shimizu","year":"2004","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"10.25259\/SNI_1398_2025\/ref-23","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1097\/00006123-199912000-00012","article-title":"Change in ventricular size and effect of ventricular catheter placement in pediatric patients with shunted hydrocephalus","volume":"45","author":"Tuli","year":"1999","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_1398_2025\/ref-24","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.jocn.2010.06.018","article-title":"Factors affecting the accuracy of ventricular catheter placement","volume":"18","author":"Wan","year":"2011","journal-title":"J Clin Neurosci"},{"key":"10.25259\/SNI_1398_2025\/ref-25","doi-asserted-by":"crossref","first-page":"157","DOI":"10.3171\/2016.8.PEDS16229","article-title":"Ventricular catheter entry site and not catheter tip location predicts shunt survival: A secondary analysis of 3 large pediatric hydrocephalus studies","volume":"19","author":"Whitehead","year":"2017","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_1398_2025\/ref-26","doi-asserted-by":"crossref","first-page":"173","DOI":"10.3171\/2014.5.PEDS13481","article-title":"Factors associated with ventricular catheter movement and inaccurate catheter location: Post hoc analysis of the hydrocephalus clinical research network ultrasound-guided shunt placement study","volume":"14","author":"Whitehead","year":"2014","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_1398_2025\/ref-27","doi-asserted-by":"crossref","first-page":"565","DOI":"10.3171\/2013.9.PEDS1346","article-title":"No significant improvement in the rate of accurate ventricular catheter location using ultrasound-guided CSF shunt insertion: A prospective, controlled study by the Hydrocephalus Clinical Research Network","volume":"12","author":"Whitehead","year":"2013","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_1398_2025\/ref-28","doi-asserted-by":"crossref","first-page":"257","DOI":"10.3171\/2021.9.PEDS21391","article-title":"Anterior versus posterior entry site for ventriculoperitoneal shunt insertion: A randomized controlled trial by the hydrocephalus clinical research network","volume":"29","author":"Whitehead","year":"2022","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_1398_2025\/ref-29","doi-asserted-by":"crossref","first-page":"66","DOI":"10.3171\/2012.11.JNS111384","article-title":"Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation","volume":"119","author":"Wilson","year":"2013","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-30","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1227\/ONS.0000000000000047","article-title":"A morphometric analysis of commonly used craniometric approaches for freehand ventriculoperitoneal shunting","volume":"22","author":"Woo","year":"2022","journal-title":"Oper Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-31","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.clineuro.2016.05.024","article-title":"Frameless, electromagnetic image-guided ventriculostomy for ventriculoperitoneal shunt and Ommaya reservoir placement","volume":"147","author":"Xu","year":"2016","journal-title":"Clin Neurol Neurosurg"},{"key":"10.25259\/SNI_1398_2025\/ref-32","doi-asserted-by":"crossref","first-page":"798488","DOI":"10.3389\/fneur.2021.798488","article-title":"Reconsidering ventriculoperitoneal shunt surgery and postoperative shunt valve pressure adjustment: Our approaches learned from past challenges and failures","volume":"12","author":"Yamada","year":"2021","journal-title":"Front Neurol"},{"key":"10.25259\/SNI_1398_2025\/ref-33","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.jocn.2012.01.041","article-title":"Relationship of the location of the ventricular catheter tip and function of the ventriculoperitoneal shunt","volume":"20","author":"Yamada","year":"2013","journal-title":"J Clin Neurosci"},{"key":"10.25259\/SNI_1398_2025\/ref-34","doi-asserted-by":"crossref","first-page":"11525","DOI":"10.1038\/s41598-023-38567-y","article-title":"The accuracy and safety of intraoperative ultrasound-guided external ventricular drainage in intraventricular hemorrhage","volume":"13","author":"Zhang","year":"2023","journal-title":"Sci Rep"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/predominance-of-ventricular-catheter-misplacement-with-anterior-approach-in-neonates-and-infants\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/predominance-of-ventricular-catheter-misplacement-with-anterior-approach-in-neonates-and-infants\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T06:30:06Z","timestamp":1779431406000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/predominance-of-ventricular-catheter-misplacement-with-anterior-approach-in-neonates-and-infants\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,22]]},"references-count":33,"alternative-id":["10.25259\/SNI_1398_2025"],"URL":"https:\/\/doi.org\/10.25259\/sni_1398_2025","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,22]]},"article-number":"300"}}