{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T08:07:37Z","timestamp":1776413257216,"version":"3.51.2"},"reference-count":14,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Percutaneous balloon compression of the Gasserian ganglion is a well-established surgical technique for the treatment of trigeminal neuralgia and is associated with a low incidence of serious complications. Vascular injury leading to subarachnoid hemorrhage is an extremely rare but potentially fatal event.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Case Description:<\/jats:title>\n                    <jats:p>A 50-year-old man with right-sided idiopathic trigeminal neuralgia refractory to medical therapy underwent percutaneous balloon compression of the Gasserian ganglion. Due to insufficient balloon configuration and early pain recurrence, a repeat procedure was performed. During the second intervention, excessive needle advancement during puncture of the foramen ovale resulted in vascular injury and the development of Fisher grade III subarachnoid hemorrhage. Postoperatively, the patient developed severe cerebral vasospasm without a focal neurological deficit. Management included intensive care monitoring, oral nimodipine therapy, serial transcranial Doppler ultrasonography with Lindegaard index assessment, and chemical angioplasty. Despite persistently elevated blood flow velocities, further endovascular intervention was deferred because of clinical stability. The patient was discharged in satisfactory condition and remained free of facial pain and neurological deficits during a 6-month follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Although percutaneous balloon compression of the Gasserian ganglion is generally safe, technical errors during foramen ovale puncture may result in catastrophic vascular complications. Careful intraoperative technique and vigilant postoperative monitoring for delayed cerebral vasospasm are essential, and conservative management may be justified in clinically stable patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/sni_1401_2025","type":"journal-article","created":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T07:26:29Z","timestamp":1776410789000},"page":"223","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Massive subarachnoid hemorrhage after percutaneous balloon compression of the Gasserian ganglion"],"prefix":"10.25259","volume":"17","author":[{"given":"Egor Dmitrievich","family":"Anisimov","sequence":"first","affiliation":[{"name":"Federal Center of Neurosurgery, Novosibirsk, Russian Federation"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergey Afanasievich","family":"Kim","sequence":"additional","affiliation":[{"name":"Federal Center of Neurosurgery, Novosibirsk, Russian Federation"},{"name":"Novosibirsk State Medical University, Novosibirsk, Russian Federation"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jamil Afetovich","family":"Rzaev","sequence":"additional","affiliation":[{"name":"Federal Center of Neurosurgery, Novosibirsk, Russian Federation"},{"name":"Novosibirsk State Medical University, Novosibirsk, Russian Federation"},{"name":"Novosibirsk State University, Novosibirsk, Russian Federation"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2026,4,17]]},"reference":[{"key":"10.25259\/SNI_1401_2025\/ref-1","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1007\/BF01411438","article-title":"Percutaneous balloon compression of the Gasserian ganglion in trigeminal neuralgia. Long-term results in 150 cases","volume":"136","author":"Abdennebi","year":"1995","journal-title":"Acta Neurochir (Wien)"},{"key":"10.25259\/SNI_1401_2025\/ref-2","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1159\/000099922","article-title":"Long-term results of percutaneous compression of the gasserian ganglion in trigeminal neuralgia (series of 200 patients)","volume":"68","author":"Abdennebi","year":"1997","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.25259\/SNI_1401_2025\/ref-3","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/S1130-1473(05)70425-5","article-title":"Acute subdural and intratemporal hematoma as a complication of percutaneous compression of the gasserian ganglion for trigeminal neuralgia","volume":"16","author":"Arrese","year":"2005","journal-title":"Neurocirugia (Astur)"},{"key":"10.25259\/SNI_1401_2025\/ref-4","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.3171\/foc.1996.1.2.11","article-title":"Percutaneous balloon compression of the trigeminal nerve for treatment of trigeminal neuralgia","volume":"1","author":"Brown","year":"1996","journal-title":"Neurosurg Focus"},{"key":"10.25259\/SNI_1401_2025\/ref-5","first-page":"e25538","article-title":"Cone beam CT with flat panel detector and biplane fluoroscopy-guided percutaneous trigeminal nerve rhizotomy using three-dimensional needle trajectory planning","volume":"14","author":"Cohen","year":"2022","journal-title":"Cureus"},{"key":"10.25259\/SNI_1401_2025\/ref-6","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1227\/ons.0000000000000395","article-title":"Percutaneous balloon compression for treatment of trigeminal neuralgia assisted by O-arm O2-based navigation: Case series and review of the literature","volume":"23","author":"D\u2019Ercole","year":"2022","journal-title":"Oper Neurosurg"},{"key":"10.25259\/SNI_1401_2025\/ref-7","doi-asserted-by":"crossref","first-page":"36","DOI":"10.4103\/sni.sni_443_16","article-title":"Carotid cavernous fistula after percutaneous balloon compression for trigeminal neuralgia: Endovascular treatment with coils","volume":"8","author":"Gatto","year":"2017","journal-title":"Surg Neurol Int"},{"key":"10.25259\/SNI_1401_2025\/ref-8","doi-asserted-by":"crossref","first-page":"E619","DOI":"10.36076\/ppj.2024.7.E619","article-title":"Technique of awake computed tomography-guided percutaneous balloon compression of the gasserian ganglion for trigeminal neuralgia","volume":"27","author":"Huang","year":"2024","journal-title":"Pain Physician"},{"key":"10.25259\/SNI_1401_2025\/ref-9","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1159\/000202976","article-title":"Avoiding abducens nerve palsy during the percutaneous balloon compression procedure","volume":"87","author":"Kefalopoulou","year":"2009","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.25259\/SNI_1401_2025\/ref-10","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/S0090-3019(03)00253-2","article-title":"Percutaneous trigeminal ganglion balloon compression for treatment of trigeminal neuralgia, part II: Results related to compression duration","volume":"60","author":"Lee","year":"2003","journal-title":"Surg Neurol"},{"key":"10.25259\/SNI_1401_2025\/ref-11","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1186\/s12883-023-03199-2","article-title":"Robot-assisted percutaneous balloon compression for trigeminal neuralgia-preliminary experiences","volume":"23","author":"Li","year":"2023","journal-title":"BMC Neurol"},{"key":"10.25259\/SNI_1401_2025\/ref-12","first-page":"148","article-title":"Subarachnoid hemorrhage and \u201cnormal pressure hydrocephalus\u201d: Fatal complication of percutaneous microcompression of the gasserian ganglion. Case report","volume":"22","author":"Spaziante","year":"1988","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_1401_2025\/ref-13","first-page":"e43645","article-title":"Percutaneous balloon compression for the treatment of trigeminal neuralgia: A review of 10 years of clinical experience","volume":"15","author":"Valenzuela Cecchi","year":"2023","journal-title":"Cureus"},{"key":"10.25259\/SNI_1401_2025\/ref-14","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00701-024-05947-w","article-title":"Efficacy and safety of percutaneous balloon compression for bilateral trigeminal neuralgia: A retrospective study","volume":"166","author":"Wang","year":"2024","journal-title":"Acta Neurochir (Wien)"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/massive-subarachnoid-hemorrhage-after-percutaneous-balloon-compression-of-the-gasserian-ganglion\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/massive-subarachnoid-hemorrhage-after-percutaneous-balloon-compression-of-the-gasserian-ganglion\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T07:26:39Z","timestamp":1776410799000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/massive-subarachnoid-hemorrhage-after-percutaneous-balloon-compression-of-the-gasserian-ganglion\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,17]]},"references-count":14,"alternative-id":["10.25259\/SNI_1401_2025"],"URL":"https:\/\/doi.org\/10.25259\/sni_1401_2025","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4,17]]},"article-number":"223"}}