{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T12:05:56Z","timestamp":1780056356121,"version":"3.54.0"},"reference-count":17,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Exoscopes provide ergonomic and visualization advantages over conventional surgical microscopes. Despite their growing adoption, the impact of device draping on transient airborne particulate generation during setup, a critical but understudied contributor to surgical site contamination, remains unclear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective observational study compared airborne particle dynamics during draping of a surgical microscope (Pentero) and an exoscope (Orbeye) in ten spinal surgeries (five per group) conducted in a laminar airflow operating room with high-efficiency particulate air filtration. Airborne particles sized 0.5 \u03bcm and 1.0 \u03bcm were recorded at 5 s intervals for 1 min from drape initiation. Cumulative exposure was analyzed using the area under the curve (AUC), and temporal dispersion patterns were analyzed using linear mixed-effects models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Cumulative airborne particle exposure did not differ significantly between devices for either 0.5 \u03bcm or 1.0 \u03bcm particles, although 0.5 \u03bcm AUC values tended to be lower with the exoscope. Time-resolved analysis demonstrated a significant time-by-device interaction for 0.5 \u03bcm particles (\n                      <jats:italic>p<\/jats:italic>\n                      = 0.039), with lower particle counts observed with the exoscope at drape initiation. This device-dependent transient behavior was not observed for larger particles (1.0 \u03bcm).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Transient airborne particle behavior during draping appears to be influenced by device configuration and draping mechanics rather than cumulative exposure alone. Awareness of device-specific airflow interactions and controlled draping practices may help mitigate transient contamination risk and enhance intraoperative environmental safety.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/sni_252_2026","type":"journal-article","created":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T11:19:54Z","timestamp":1780053594000},"page":"320","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Airborne particle dynamics during draping of a surgical microscope versus an exoscope in spinal surgery: A prospective comparative study"],"prefix":"10.25259","volume":"17","author":[{"given":"Yuki","family":"Umeno","sequence":"first","affiliation":[{"name":"Nursing Division, [Operating Room], Juntendo University Hospital, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eiji","family":"Abe","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Spine and Spinal Cord Center, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Hara","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Spine and Spinal Cord Center, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukoh","family":"Ohara","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Spine and Spinal Cord Center, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihide","family":"Kondo","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Juntendo University Hospital, Bunkyo-ku, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2026,5,29]]},"reference":[{"key":"10.25259\/SNI_252_2026\/ref-1","doi-asserted-by":"crossref","first-page":"8","DOI":"10.4184\/asj.2013.7.1.8","article-title":"The degree of bacterial contamination while performing spine surgery","volume":"7","author":"Ahn","year":"2013","journal-title":"Asian Spine J"},{"key":"10.25259\/SNI_252_2026\/ref-2","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1017\/ice.2014.9","article-title":"Influence of staff behavior on infectious risk in operating rooms: What is the evidence?","volume":"36","author":"Birgand","year":"2015","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.25259\/SNI_252_2026\/ref-3","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jhin.2025.09.006","article-title":"Correlation of airborne bacteria in the operating room with surgical wound contamination and surgical site infection: A systematic review","volume":"166","author":"Caous","year":"2025","journal-title":"J Hosp Infect"},{"key":"10.25259\/SNI_252_2026\/ref-4","doi-asserted-by":"crossref","first-page":"S77","DOI":"10.1016\/j.otsr.2014.07.028","article-title":"Preventing surgical-site infections: Measures other than antibiotics","volume":"101","author":"Chauveaux","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.25259\/SNI_252_2026\/ref-5","doi-asserted-by":"crossref","first-page":"108662","DOI":"10.1016\/j.abb.2020.108662","article-title":"Effects of air pollution particles (ultrafine and fine particulate matter) on mitochondrial function and oxidative stress-Implications for cardiovascular and neurodegenerative diseases","volume":"696","author":"Daiber","year":"2020","journal-title":"Arch Biochem Biophys"},{"key":"10.25259\/SNI_252_2026\/ref-6","doi-asserted-by":"crossref","first-page":"zraf044","DOI":"10.1093\/bjsopen\/zraf044","article-title":"Effect of the number of door openings in the operating room on surgical site infections: Individual-patient data meta-analysis","volume":"9","author":"Groenen","year":"2025","journal-title":"BJS Open"},{"key":"10.25259\/SNI_252_2026\/ref-7","doi-asserted-by":"crossref","first-page":"100258","DOI":"10.1016\/j.wnsx.2023.100258","article-title":"Comparative analysis of exoscope-assisted spine surgery versus operating microscope: A systematic review","volume":"21","author":"Iqbal","year":"2023","journal-title":"World Neurosurg X"},{"key":"10.25259\/SNI_252_2026\/ref-8","doi-asserted-by":"crossref","first-page":"342","DOI":"10.3171\/2012.7.SPINE12203","article-title":"Infection risk for primary and revision instrumented lumbar spine fusion in the Medicare population","volume":"17","author":"Kurtz","year":"2012","journal-title":"J Neurosurg Spine"},{"key":"10.25259\/SNI_252_2026\/ref-9","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1111\/j.1600-0668.2011.00723.x","article-title":"CFD and ventilation research","volume":"21","author":"Li","year":"2011","journal-title":"Indoor Air"},{"key":"10.25259\/SNI_252_2026\/ref-10","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1186\/s12893-023-02026-2","article-title":"A meta-analysis of risk factors for non-superficial surgical site infection following spinal surgery","volume":"23","author":"Liu","year":"2023","journal-title":"BMC Surg"},{"key":"10.25259\/SNI_252_2026\/ref-11","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.wneu.2021.03.055","article-title":"Negative pressure assisted microenvironment surgical hood: A novel cost-effective device to minimize aerosol contamination during neurosurgical procedures in times of COVID-19","volume":"150","author":"Patir","year":"2021","journal-title":"World Neurosurg"},{"key":"10.25259\/SNI_252_2026\/ref-12","doi-asserted-by":"crossref","first-page":"23911","DOI":"10.1038\/s41598-025-08394-4","article-title":"Assessing HVAC airflow modulation strategies to reduce short-term aerosol transmission in office environments","volume":"15","author":"Saad","year":"2025","journal-title":"Sci Rep"},{"key":"10.25259\/SNI_252_2026\/ref-13","first-page":"106606","article-title":"A systematic review of operating room ventilation","volume":"72","author":"Sadrizadeh","year":"2023","journal-title":"J Build Eng"},{"key":"10.25259\/SNI_252_2026\/ref-14","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1007\/s00701-021-04874-4","article-title":"Surgically generated aerosol and mitigation strategies: Combined use of irrigation, respirators and suction massively reduces particulate matter aerosol","volume":"163","author":"Schramm","year":"2021","journal-title":"Acta Neurochir (Wien)"},{"key":"10.25259\/SNI_252_2026\/ref-15","doi-asserted-by":"crossref","first-page":"S125","DOI":"10.1097\/BRS.0b013e3181d8342c","article-title":"The influence of perioperative risk factors and therapeutic interventions on infection rates after spine surgery: A systematic review","volume":"35","author":"Schuster","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.25259\/SNI_252_2026\/ref-16","doi-asserted-by":"crossref","first-page":"5S","DOI":"10.1177\/2192568218799056","article-title":"Surgical site infection in spine surgery: Who is at risk?","volume":"8","author":"Yao","year":"2018","journal-title":"Global Spine J"},{"key":"10.25259\/SNI_252_2026\/ref-17","doi-asserted-by":"crossref","first-page":"e28836","DOI":"10.1097\/MD.0000000000028836","article-title":"Risk factors for surgical site infection following spinal surgery: A meta-analysis","volume":"101","author":"Zhang","year":"2022","journal-title":"Medicine (Baltimore)"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/airborne-particle-dynamics-during-draping-of-a-surgical-microscope-versus-an-exoscope-in-spinal-surgery-a-prospective-comparative-study\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/airborne-particle-dynamics-during-draping-of-a-surgical-microscope-versus-an-exoscope-in-spinal-surgery-a-prospective-comparative-study\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T11:19:57Z","timestamp":1780053597000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/airborne-particle-dynamics-during-draping-of-a-surgical-microscope-versus-an-exoscope-in-spinal-surgery-a-prospective-comparative-study\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,29]]},"references-count":17,"alternative-id":["10.25259\/SNI_252_2026"],"URL":"https:\/\/doi.org\/10.25259\/sni_252_2026","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,29]]},"article-number":"320"}}