{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T17:23:16Z","timestamp":1775323396805,"version":"3.50.1"},"reference-count":20,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Background: <\/jats:title>\n<jats:p>The middle cerebral artery (MCA) is a common site of cerebral aneurysms and 82.6% occur at the bifurcation. When surgery is selected as a therapeutic option, it intends to clip the neck completely because if some remnant occurs, there exists the possibility of regrowth and bleeding in the short- or long-term.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Methods: <\/jats:title>\n<jats:p>We analyzed one drawback of the fenestrated clips of Yasargil and Sugita types to occlude the neck totally at a specific point formed by the union of the fenestra with the blades, creating a triangular space where the aneurysm can protrude, giving place to a remnant that can lead to a future recurrence and rebleeding. We show two cases of ruptured MCA aneurysms in which a cross-clipping technique occluded a broad base and dysmorphic aneurysm using straight fenestrated clips.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Results: <\/jats:title>\n<jats:p>In both cases (one using a Yasargil clip and the other with a Sugita clip), a small remnant was visualized when fluorescein videoangiography (FL-VAG) was used. In both cases, the small remnant was clipped with a 3 mm straight miniclip.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st4\">\n<jats:title>Conclusion: <\/jats:title>\n<jats:p>We should be aware of this drawback when clipping aneurysms using fenestrated clips to ensure a complete obliteration of the aneurysm\u2019s neck.<\/jats:p>\n<\/jats:sec>","DOI":"10.25259\/sni_374_2023","type":"journal-article","created":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T04:48:16Z","timestamp":1687409296000},"page":"204","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Limitation of fenestrated clips during clipping of middle cerebral artery aneurysm: Technical note"],"prefix":"10.25259","volume":"14","author":[{"given":"Javier","family":"Degollado-Garc\u00eda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H\u00e9ctor A.","family":"Rodr\u00edguez-Rubio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alfredo","family":"Bonilla-Suastegui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alejandro","family":"Serrano-Rubio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos F.","family":"Nicolas-Cruz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edgar","family":"Nathal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2023,6,16]]},"reference":[{"key":"10.25259\/SNI_374_2023\/ref-1","first-page":"339","article-title":"Application of a new fenestrated clip (Ya\u015fargil T-bar clip) for the treatment of fusiform M1 aneurysm: Case illustration and technical report","volume":"70","author":"Ba\u015fkaya","year":"2012","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_374_2023\/ref-2","first-page":"84","article-title":"Inappropriate application of Ya\u015fargil aneurysm clips: A new observation and technical remark","volume":"66","author":"Celik","year":"2010","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_374_2023\/ref-3","doi-asserted-by":"crossref","first-page":"396","DOI":"10.3171\/jns.1999.91.3.0396","article-title":"Late angiographic follow-up review of surgically treated aneurysms","volume":"91","author":"David","year":"1999","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_374_2023\/ref-4","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s00330-004-2614-8","article-title":"Intracranial aneurysms","volume":"15","author":"Gasparotti","year":"2005","journal-title":"Eur Radiol"},{"key":"10.25259\/SNI_374_2023\/ref-5","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/s10143-011-0347-0","article-title":"Scissoring of cerebral aneurysm clips: Mechanical endurance of clip twisting","volume":"35","author":"Horiuchi","year":"2012","journal-title":"Neurosurg Rev"},{"key":"10.25259\/SNI_374_2023\/ref-6","doi-asserted-by":"crossref","first-page":"273","DOI":"10.2176\/nmc.49.273","article-title":"Concept of ideal closure line for clipping of middle cerebral artery aneurysms--technical note","volume":"49","author":"Ishikawa","year":"2009","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"10.25259\/SNI_374_2023\/ref-7","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1093\/ons\/opx033","article-title":"Treatment of recurrent intracranial aneurysms after neck clipping: Novel classification scheme and management strategies","volume":"13","author":"Kobayashi","year":"2017","journal-title":"Oper Neurosurg (Hagerstown)"},{"key":"10.25259\/SNI_374_2023\/ref-8","first-page":"336","article-title":"The new aneurysm clip system for particularly complex aneurysm surgery: Technical note","volume":"66","author":"Krammer","year":"2010","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_374_2023\/ref-9","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.surneu.2005.08.025","article-title":"Water dissection technique of Toth for opening neurosurgical cleavage planes","volume":"65","author":"Nagy","year":"2006","journal-title":"Surg Neurol"},{"key":"10.25259\/SNI_374_2023\/ref-10","first-page":"178","article-title":"Anatomic and surgical basis of the sphenoid ridge keyhole approach for cerebral aneurysms","volume":"56","author":"Nathal","year":"2005","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_374_2023\/ref-11","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/0090-3019(95)80032-C","article-title":"Surgical management of middle cerebral artery aneurysms: Experience with transsylvian and superior temporal gyrus approaches","volume":"43","author":"Ogilvy","year":"1995","journal-title":"Surg Neurol"},{"key":"10.25259\/SNI_374_2023\/ref-12","doi-asserted-by":"crossref","first-page":"S553","DOI":"10.4103\/2152-7806.168072","article-title":"The efficiency of the new Ya\u015fargil titanium fenestrated mini-clips for ideal clipping of a cerebral aneurysm","volume":"6","author":"Ota","year":"2015","journal-title":"Surg Neurol Int"},{"key":"10.25259\/SNI_374_2023\/ref-13","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.3171\/2009.9.JNS09827","article-title":"Mechanical characteristics and surface elemental composition of a Ya\u015fargil titanium aneurysm clip after long-term implantation","volume":"112","author":"Otawara","year":"2010","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_374_2023\/ref-14","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1227\/01.NEU.0000116140.53925.03","article-title":"Endurance of aneurysm clips: Mechanical endurance of Ya\u015fargil and Spetzler titanium aneurysm clips","volume":"54","author":"Papadopoulos","year":"2004","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_374_2023\/ref-15","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/00006123-199601000-00002","article-title":"Analysis of 561 patients with 690 middle cerebral artery aneurysms: Anatomic and clinical features as correlated to management outcome","volume":"38","author":"Rinne","year":"1996","journal-title":"Neurosurgery"},{"key":"10.25259\/SNI_374_2023\/ref-16","doi-asserted-by":"crossref","first-page":"723","DOI":"10.3171\/jns.1976.44.6.0723","article-title":"Comparative study of the pressure of various aneurysm clips","volume":"44","author":"Sugita","year":"1976","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_374_2023\/ref-17","doi-asserted-by":"crossref","first-page":"17","DOI":"10.3171\/jns.1984.61.1.0017","article-title":"Surgical treatment of middle cerebral artery aneurysms","volume":"61","author":"Suzuki","year":"1984","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_374_2023\/ref-18","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1007\/s007010050018","article-title":"Clinical safety and performance of Sugita titanium aneurysm clips","volume":"142","author":"Takayasu","year":"2000","journal-title":"Acta Neurochir (Wien)"},{"key":"10.25259\/SNI_374_2023\/ref-19","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.wneu.2019.01.191","article-title":"\u201cMass reduction\u201d clipping technique for large and complex intracranial middle cerebral artery aneurysm","volume":"125","author":"Takeda","year":"2019","journal-title":"World Neurosurg"},{"key":"10.25259\/SNI_374_2023\/ref-20","first-page":"124","article-title":"Microneurosurgery","volume":"2","author":"Ya\u015fargil","year":"1984"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/limitation-of-fenestrated-clips-during-clipping-of-middle-cerebral-artery-aneurysm-technical-note\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/limitation-of-fenestrated-clips-during-clipping-of-middle-cerebral-artery-aneurysm-technical-note\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T07:07:22Z","timestamp":1687417642000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/limitation-of-fenestrated-clips-during-clipping-of-middle-cerebral-artery-aneurysm-technical-note\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,16]]},"references-count":20,"alternative-id":["10.25259\/SNI_374_2023"],"URL":"https:\/\/doi.org\/10.25259\/sni_374_2023","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6,16]]},"article-number":"204"}}