{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T08:13:13Z","timestamp":1788509593509,"version":"build-2803163510"},"reference-count":16,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Selecting the flow diverter (FD) size is key to treatment outcomes in unruptured intracranial aneurysms. However, the impact of differences between the nominal and actual deployed device sizes on aneurysm occlusion is not fully understood. This study retrospectively evaluated the relationship between FD size and aneurysm occlusion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We retrospectively analyzed 54 patients with unruptured intracranial aneurysms who underwent FD placement at our institution from March 2023 to March 2025, where both length (Length_D) and diameter (Size_D) discrepancies were evaluated. Devices used were a Flow Redirection Endoluminal Device in 31 cases and a Pipeline Embolization Device in 23 cases. Length_D is the difference between the nominal device length and actual deployed length, while Size_D is the difference between the nominal device diameter and actual deployed diameter. The primary endpoint was aneurysm occlusion at 6 months, assessed using the O\u2019Kelly\u2013Marotta (OKM) scale. Adequate occlusion was defined as OKM grades C\u2013D and incomplete occlusion as OKM grades A\u2013B. Patients were divided into adequate and incomplete occlusion groups, and Length_D and Size_D were compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Adequate occlusion was achieved in 68.5% of patients. The mean Length_D was 2.9 \u00b1 3.9 mm in the adequate occlusion group and 6.7 \u00b1 5.1 mm in the incomplete occlusion group, with a significantly greater value in the incomplete occlusion group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Greater FD elongation post-deployment may be linked to lower aneurysm occlusion rates at 6 months. Choosing an FD size that matches the parent vessel diameter is crucial for optimal occlusion.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/sni_564_2026","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T07:28:15Z","timestamp":1788506895000},"page":"496","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Closer matching between flow diverter diameter and parent artery diameter is associated with improved aneurysm occlusion"],"prefix":"10.25259","volume":"17","author":[{"given":"Yoshimasa","family":"Fukui","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Fujii","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kunihiro","family":"Matsumoto","sequence":"additional","affiliation":[{"name":"Department of Radiology, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuta","family":"Maehara","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kousei","family":"Maruyama","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kousuke","family":"Takigawa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Yasaka","sequence":"additional","affiliation":[{"name":"Cerebrovascular Medicine, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Aikawa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinori","family":"Go","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidenori","family":"Oishi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Oishi Neurosurgical Clinic, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyoshi","family":"Kazekawa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Fukuoka Neurosurgical Hospital, Fukuoka, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"key":"10.25259\/SNI_564_2026\/ref-1","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1148\/radiol.13120099","article-title":"Pipeline for uncoilable or failed aneurysms: Results from a multicenter clinical trial","volume":"267","author":"Becske","year":"2013","journal-title":"Radiology"},{"key":"10.25259\/SNI_564_2026\/ref-2","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1161\/STROKEAHA.112.678151","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: A meta-analysis","volume":"44","author":"Brinjikji","year":"2013","journal-title":"Stroke"},{"key":"10.25259\/SNI_564_2026\/ref-3","doi-asserted-by":"crossref","first-page":"2309","DOI":"10.3174\/ajnr.A5388","article-title":"Treatment of middle cerebral artery aneurysms with flow-diverter stents: A systematic review and meta-analysis","volume":"38","author":"Cagnazzo","year":"2017","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/SNI_564_2026\/ref-4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s13239-019-00445-y","article-title":"Hydrodynamic resistance of intracranial flow-diverter stents: Measurement description and data evaluation","volume":"11","author":"Csippa","year":"2020","journal-title":"Cardiovasc Eng Technol"},{"key":"10.25259\/SNI_564_2026\/ref-5","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1136\/neurintsurg-2020-015877","article-title":"Review of current intracranial aneurysm flow diversion technology and clinical use","volume":"13","author":"Dandapat","year":"2021","journal-title":"J Neurointerv Surg"},{"key":"10.25259\/SNI_564_2026\/ref-6","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s00062-021-01106-1","article-title":"Impact of design and deployment technique on the hydrodynamic resistance of flow diverters: An in vitro experimental study","volume":"32","author":"Gy\u00fcrki","year":"2022","journal-title":"Clin Neuroradiol"},{"key":"10.25259\/SNI_564_2026\/ref-7","doi-asserted-by":"crossref","first-page":"10653","DOI":"10.1038\/s41598-024-61312-y","article-title":"Quantitative analysis of hemodynamic changes induced by the discrepancy between the sizes of the flow diverter and parent artery","volume":"14","author":"Kim","year":"2024","journal-title":"Sci Rep"},{"key":"10.25259\/SNI_564_2026\/ref-8","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3174\/ajnr.A8079","article-title":"Correlation of flow diverter malapposition at the aneurysm neck with incomplete aneurysm occlusion in patients with small intracranial aneurysms: A single-center experience","volume":"45","author":"Long","year":"2023","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/SNI_564_2026\/ref-9","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.3174\/ajnr.A3933","article-title":"Enhanced aneurysmal flow diversion using a dynamic push-pull technique: An experimental and modeling study","volume":"35","author":"Ma","year":"2014","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/SNI_564_2026\/ref-10","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1136\/jnis-2022-019993","article-title":"Predictors of aneurysm occlusion after treatment with flow diverters: A systematic literature review","volume":"16","author":"Meyer","year":"2024","journal-title":"J Neurointerv Surg"},{"key":"10.25259\/SNI_564_2026\/ref-11","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1177\/159101991001600204","article-title":"A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents","volume":"16","author":"O\u2019Kelly","year":"2010","journal-title":"Interv Neuroradiol"},{"key":"10.25259\/SNI_564_2026\/ref-12","doi-asserted-by":"crossref","first-page":"365","DOI":"10.3174\/ajnr.A8076","article-title":"Intraluminal flow diverter design primer for neurointerventionalists","volume":"45","author":"Oliver","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.25259\/SNI_564_2026\/ref-13","doi-asserted-by":"crossref","first-page":"172","DOI":"10.3171\/2023.5.JNS222403","article-title":"Pipeline embolization device dynamics: Prediction of incomplete occlusion by elongation from nominal length","volume":"140","author":"Sunohara","year":"2024","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_564_2026\/ref-14","doi-asserted-by":"crossref","first-page":"1499732","DOI":"10.3389\/fneur.2024.1499732","article-title":"An increase in flow-diverter oversizing values as an independent risk factor for developing more severe in-stent stenosis. A retrospective single-center study based on flow diversion of supraclinoid internal carotid artery aneurysms","volume":"15","author":"Vladev","year":"2025","journal-title":"Front Neurol"},{"key":"10.25259\/SNI_564_2026\/ref-15","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1016\/j.jocn.2010.10.011","article-title":"Flow diverters for treatment of intracranial aneurysms: Current status and ongoing clinical trials","volume":"18","author":"Wong","year":"2011","journal-title":"J Clin Neurosci"},{"key":"10.25259\/SNI_564_2026\/ref-16","doi-asserted-by":"crossref","first-page":"59","DOI":"10.5797\/jnet.ra.2023-0078","article-title":"A review of current flow diverters","volume":"18","author":"Yamada","year":"2024","journal-title":"J Neuroendovasc Ther"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/closer-matching-between-flow-diverter-diameter-and-parent-artery-diameter-is-associated-with-improved-aneurysm-occlusion\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/closer-matching-between-flow-diverter-diameter-and-parent-artery-diameter-is-associated-with-improved-aneurysm-occlusion\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T07:28:17Z","timestamp":1788506897000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/closer-matching-between-flow-diverter-diameter-and-parent-artery-diameter-is-associated-with-improved-aneurysm-occlusion\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":16,"alternative-id":["10.25259\/SNI_564_2026"],"URL":"https:\/\/doi.org\/10.25259\/sni_564_2026","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9,4]]},"article-number":"496"}}