{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T09:02:35Z","timestamp":1718960555529},"reference-count":14,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Background: <\/jats:title>\n<jats:p>Extracranial internal carotid artery (ICA)-dissecting aneurysms (DAs) rarely cause re-entry tears and lower cranial nerve palsies. The therapeutic strategies for these pathologies are not well established. This report presents a case of an extracranial ICA -DA with a re-entry tear that caused lower cranial nerve palsy.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Case Description: <\/jats:title>\n<jats:p>A 60-year-old man presented with left neck pain, hoarseness, and dysphagia. Physical examination and laryngoscopy determined palsies of the left cranial nerves IX, X, and XII. Digital subtraction angiography (DSA) revealed a DA in the left extracranial ICA, and three-dimensional DSA showed entry and re-entry tears in the intimal flap. Flow-diverting stents (FDSs) were placed on the lesion that covered the entry and re-entry tears because the symptoms did not improve after five weeks of conservative treatment. A post-procedural angiogram indicated flow stagnation in the DA. Symptoms improved remarkably immediately after the procedure, and the aneurysm was almost completely occluded six months later.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Conclusion: <\/jats:title>\n<jats:p>Herein, an extracranial ICA -DA with a re-entry tear that caused lower cranial nerve palsy did not improve after five weeks of conservative treatment. FDS placement promptly resolved the aneurysm and symptoms. Thus, FDS placement may be an effective treatment option for extracranial ICA-DAs with re-entry tears or lower cranial nerve palsies.<\/jats:p>\n<\/jats:sec>","DOI":"10.25259\/sni_57_2024","type":"journal-article","created":{"date-parts":[[2024,4,12]],"date-time":"2024-04-12T09:26:20Z","timestamp":1712913980000},"page":"126","update-policy":"http:\/\/dx.doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Extracranial internal carotid artery-dissecting aneurysm having a re-entry tear and causing lower cranial nerve palsies treated with flow-diverting stent: A case report"],"prefix":"10.25259","volume":"15","author":[{"given":"Nobuyuki","family":"Izutsu","sequence":"first","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Nishizawa","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shin","family":"Nakajima","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yonehiro","family":"Kanemura","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"},{"name":"Department of Biomedical Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiko","family":"Ozaki","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsunori","family":"Asai","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoki","family":"Kidani","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yosuke","family":"Fujimi","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiyuki","family":"Fujinaka","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Research and Innovation, NHO Osaka National Hospital, Osaka, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2024,4,12]]},"reference":[{"key":"10.25259\/SNI_57_2024\/ref-1","doi-asserted-by":"crossref","first-page":"1048.e1","DOI":"10.1016\/j.wneu.2017.08.016","article-title":"Ruptured vertebral artery dissecting aneurysm concurrent with spontaneous cervical internal carotid artery dissection: A report of three cases and literature review","volume":"107","author":"Akamatsu","year":"2017","journal-title":"World Neurosurg"},{"key":"10.25259\/SNI_57_2024\/ref-2","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.avsg.2017.06.151","article-title":"Flow-diverting stent in the treatment of cervical carotid dissection and pseudoaneurysm: Review of literature and case report","volume":"46","author":"Baptista-Sincos","year":"2018","journal-title":"Ann Vasc Surg"},{"key":"10.25259\/SNI_57_2024\/ref-3","doi-asserted-by":"crossref","first-page":"e241156","DOI":"10.1136\/bcr-2020-241156","article-title":"Use of flow diverter stent for treatment of a cervical carotid artery dissection and pseudoaneurysm causing Horner\u2019s syndrome","volume":"14","author":"Beaty","year":"2021","journal-title":"BMJ Case Rep"},{"key":"10.25259\/SNI_57_2024\/ref-4","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1212\/WNL.0b013e31822f03fc","article-title":"Differential features of carotid and vertebral artery dissections: The CADISP study","volume":"77","author":"Debette","year":"2011","journal-title":"Neurology"},{"key":"10.25259\/SNI_57_2024\/ref-5","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.wneu.2022.03.045","article-title":"Endovascular flow diversion in cervical internal carotid artery dissections","volume":"162","author":"Diana","year":"2022","journal-title":"World Neurosurg"},{"key":"10.25259\/SNI_57_2024\/ref-6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3941\/jrcr.v10i6.1618","article-title":"Carotid stent fracture from stylocarotid syndrome","volume":"10","author":"Hooker","year":"2016","journal-title":"J Radiol Case Rep"},{"key":"10.25259\/SNI_57_2024\/ref-7","doi-asserted-by":"crossref","first-page":"225","DOI":"10.25259\/SNI_184_2022","article-title":"Carotid artery stenting for spontaneous internal carotid artery dissection presenting with hypoglossal nerve palsy: A case report","volume":"13","author":"Kidoguchi","year":"2022","journal-title":"Surg Neurol Int"},{"key":"10.25259\/SNI_57_2024\/ref-8","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1212\/WNL.46.2.356","article-title":"Cranial nerve palsy in spontaneous dissection of the extracranial internal carotid artery","volume":"46","author":"Mokri","year":"1996","journal-title":"Neurology"},{"key":"10.25259\/SNI_57_2024\/ref-9","doi-asserted-by":"crossref","first-page":"183","DOI":"10.25259\/SNI_47_2022","article-title":"Carotid artery dissection due to elongated styloid process treated by acute phase carotid artery stenting: A case report","volume":"13","author":"Okada","year":"2022","journal-title":"Surg Neurol Int"},{"key":"10.25259\/SNI_57_2024\/ref-10","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.ejvs.2016.03.021","article-title":"Fate of distal false aneurysms complicating internal carotid artery dissection: A systematic review","volume":"52","author":"Paraskevas","year":"2016","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.25259\/SNI_57_2024\/ref-11","doi-asserted-by":"crossref","first-page":"72","DOI":"10.5469\/neuroint.2022.00409","article-title":"Fracture of a flow diverter in the cervical internal carotid artery due to Eagle syndrome","volume":"18","author":"Pfaff","year":"2023","journal-title":"Neurointervention"},{"key":"10.25259\/SNI_57_2024\/ref-12","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jvscit.2018.01.005","article-title":"Transcarotid artery stenting for carotid artery pseudoaneurysm using flow reversal technique","volume":"4","author":"Rizwan","year":"2018","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"10.25259\/SNI_57_2024\/ref-13","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1007\/s00062-019-00761-9","article-title":"Delayed tine displacement of a CASPER carotid artery stent due to styloid process compression","volume":"29","author":"Tan","year":"2019","journal-title":"Clin Neuroradiol"},{"key":"10.25259\/SNI_57_2024\/ref-14","doi-asserted-by":"crossref","first-page":"454","DOI":"10.5797\/jnet.cr.2019-0032","article-title":"Carotid stent fracture due to Eagle syndrome after endovascular stenting for the treatment of acute ischemic stroke caused by internal carotid artery dissection: Case report","volume":"13","author":"Yano","year":"2019","journal-title":"J Neuroendovascular Ther"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/extracranial-internal-carotid-artery-dissecting-aneurysm-having-a-re-entry-tear-and-causing-lower-cranial-nerve-palsies-treated-with-flow-diverting-stent-a-case-report\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/extracranial-internal-carotid-artery-dissecting-aneurysm-having-a-re-entry-tear-and-causing-lower-cranial-nerve-palsies-treated-with-flow-diverting-stent-a-case-report\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,12]],"date-time":"2024-04-12T09:26:27Z","timestamp":1712913987000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/extracranial-internal-carotid-artery-dissecting-aneurysm-having-a-re-entry-tear-and-causing-lower-cranial-nerve-palsies-treated-with-flow-diverting-stent-a-case-report\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,12]]},"references-count":14,"alternative-id":["10.25259\/SNI_57_2024"],"URL":"https:\/\/doi.org\/10.25259\/sni_57_2024","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4,12]]},"article-number":"126"}}