{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,12,24]],"date-time":"2022-12-24T06:04:48Z","timestamp":1671861888372},"reference-count":10,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Background: <\/jats:title>\n<jats:p>Tapping a ventriculoperitoneal shunt percutaneously using a coring needle, such as a butterfly needle, is a common neurosurgical practice despite manufacturers\u2019 recommendation to use a Huber type non-coring needle.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Case Description: <\/jats:title>\n<jats:p>A 26-year-old woman, with congenital hydrocephalus and history of multiple shunt revision and shunt taps, presented with symptoms consistent with intracranial hypotension. During her shunt revision, cerebrospinal fluid (CSF) was found to be leaking from her shunt reservoir defects which were believed to be caused by prior shunt taps. An <jats:italic>in vitro<\/jats:italic> study duplicated this finding in which several areas of leak were observed from the valve tapped using the coring needle, while none was observed from the valve tapped using the non-coring needle.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Conclusion: <\/jats:title>\n<jats:p>Taping a shunt using a coring needle can damage the shunt reservoir and cause CSF overdrainage.<\/jats:p>\n<\/jats:sec>","DOI":"10.25259\/sni_808_2022","type":"journal-article","created":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T05:40:17Z","timestamp":1671774017000},"page":"592","update-policy":"http:\/\/dx.doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Cerebral spinal fluid overdrainage from shunt tap using large bore coring needle: A case report"],"prefix":"10.25259","volume":"13","author":[{"given":"Shiwei","family":"Huang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Guillaume","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2022,12,23]]},"reference":[{"key":"10.25259\/SNI_808_2022\/ref-1","article-title":"CODMAN CERTAS\u00ae Plus Programmable Valve CODMAN CERTAS\u00ae Tool Kit","year":"2010"},{"key":"10.25259\/SNI_808_2022\/ref-2","article-title":"CODMAN HAKIM\u00ae Programmable Valves","year":"2019"},{"key":"10.25259\/SNI_808_2022\/ref-3","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/978-88-470-2373-4_4","article-title":"Huber Needle: Different Types, Uses, Prevention of Accidents","volume-title":"Total Implant Venous Access Devices","author":"Fougo","year":"2012"},{"key":"10.25259\/SNI_808_2022\/ref-4","doi-asserted-by":"crossref","first-page":"435","DOI":"10.3171\/PED\/2008\/1\/6\/435","article-title":"Rethinking the indications for the ventriculoperitoneal shunt tap","volume":"1","author":"Miller","year":"2008","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_808_2022\/ref-5","doi-asserted-by":"crossref","first-page":"328","DOI":"10.3171\/jns.1984.61.2.0328","article-title":"Shunt fluid examination: Risks and benefits in the evaluation of shunt malfunction and infection","volume":"61","author":"Noetzel","year":"1984","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_808_2022\/ref-6","first-page":"173","article-title":"A ventriculostomy reservoir","volume":"2","author":"Rickham","year":"1964","journal-title":"Br Med J"},{"key":"10.25259\/SNI_808_2022\/ref-7","doi-asserted-by":"crossref","first-page":"439","DOI":"10.3171\/PED\/2008\/1\/6\/439","article-title":"Ventricular shunt tap as a predictor of proximal shunt malfunction in children: A prospective study","volume":"1","author":"Rocque","year":"2008","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_808_2022\/ref-8","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1007\/BF00272267","article-title":"Useful components of the shunt tap test for evaluation of shunt malfunction","volume":"9","author":"Sood","year":"1993","journal-title":"Childs Nerv Syst"},{"key":"10.25259\/SNI_808_2022\/ref-9","doi-asserted-by":"crossref","first-page":"336","DOI":"10.3171\/2014.7.PEDS13612","article-title":"What is the risk of infecting a cerebrospinal fluid\u2013diverting shunt with percutaneous tapping?","volume":"14","author":"Spiegelman","year":"2014","journal-title":"J Neurosurg Pediatr"},{"key":"10.25259\/SNI_808_2022\/ref-10","article-title":"Strata\u00ae Products","year":"2018"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/cerebral-spinal-fluid-overdrainage-from-shunt-tap-using-large-bore-coring-needle-a-case-report\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/cerebral-spinal-fluid-overdrainage-from-shunt-tap-using-large-bore-coring-needle-a-case-report\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T05:40:23Z","timestamp":1671774023000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/cerebral-spinal-fluid-overdrainage-from-shunt-tap-using-large-bore-coring-needle-a-case-report\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,23]]},"references-count":10,"alternative-id":["10.25259\/SNI_808_2022"],"URL":"https:\/\/doi.org\/10.25259\/sni_808_2022","relation":{},"ISSN":["2152-7806"],"issn-type":[{"value":"2152-7806","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,23]]},"article-number":"592"}}