{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T13:34:21Z","timestamp":1770989661475,"version":"3.50.1"},"reference-count":10,"publisher":"Scientific Scholar","content-domain":{"domain":["surgicalneurologyint.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Achieving watertight dural closure in posterior fossa surgery is often challenging due to the anatomical complexity of this region, particularly when suturing is not feasible near critical venous structures. These circumstances increase the risk of cerebrospinal fluid (CSF) leakage, a well-recognized complication. Traditional single-layer techniques may be insufficient to achieve a watertight seal. To address this limitation, we developed a novel multilayer duraplasty method, termed the \u201cSandwich Technique,\u201d which combines an absorbable collagen matrix with autologous fascia.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A 69-year-old woman with a large tentorial meningioma and obstructive hydrocephalus underwent tumor resection. Intraoperatively, a wide dural defect adjacent to the transverse sinus was identified, where primary closure was not feasible. Reconstruction was performed using the three-layer Sandwich Technique: Step 1, an inlay DuraGen\n                      <jats:sup>\u00ae<\/jats:sup>\n                      sheet placed subdurally and sutured to the tentorium; Step 2, an overlay of autologous fascia lata; and Step 3, an onlay DuraGen\n                      <jats:sup>\u00ae<\/jats:sup>\n                      sheet folded over the fascia and secured with the bone flap. Fibrin glue was applied between each layer to reinforce adhesion.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Postoperative imaging confirmed a watertight closure with no evidence of CSF leakage. The patient experienced no complications, and follow-up imaging at 2 months demonstrated a stable reconstruction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The Sandwich Technique provides a simple, reproducible option for dural repair in the posterior fossa when suturing is technically difficult. This multilayer approach, which integrates synthetic and autologous materials, allows tension-free watertight closure and may represent a valuable adjunct in neurosurgical dural reconstruction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.25259\/sni_974_2025","type":"journal-article","created":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T12:28:40Z","timestamp":1770985720000},"page":"87","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Multilayer dural repair using absorbable artificial dura in the posterior fossa: A case report on the \u201csandwich technique\u201d"],"prefix":"10.25259","volume":"17","author":[{"given":"Tomona","family":"Maetani","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Jikei University Daisan Hospital, Komae-Shi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yohei","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jikei University Daisan Hospital, Komae-Shi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kogen David","family":"Okano","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jikei University Daisan Hospital, Komae-Shi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Narita","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jikei University Daisan Hospital, Komae-Shi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Kato","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jikei University, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichi","family":"Murayama","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Jikei University School of Medicine, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2026,2,13]]},"reference":[{"key":"10.25259\/SNI_974_2025\/ref-1","doi-asserted-by":"crossref","first-page":"e0319349","DOI":"10.1371\/journal.pone.0319349","article-title":"Platelet rich fibrin and commercial sealants for dural closure in neurosurgery: An in vitro study","volume":"20","author":"Argiti","year":"2025","journal-title":"PLoS One"},{"key":"10.25259\/SNI_974_2025\/ref-2","first-page":"16","article-title":"Experience with acellular human dura and bovine collagen matrix for duraplasty after posterior fossa decompression for chiari malformations","volume":"104","author":"Danish","year":"2006","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_974_2025\/ref-3","doi-asserted-by":"crossref","first-page":"735","DOI":"10.3171\/2014.6.JNS131917","article-title":"Risk factors for postoperative CSF leakage after elective craniotomy and the efficacy of fleece-bound tissue sealing against dural suturing alone: A randomized controlled trial","volume":"121","author":"Hutter","year":"2014","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_974_2025\/ref-4","doi-asserted-by":"crossref","first-page":"188","DOI":"10.18231\/j.ijn.2020.038","article-title":"Cerebrospinal fluid leak in posterior fossa surgeries with different dural closure methods-a retrospective cohort study","volume":"6","author":"Kollannur","year":"2020","journal-title":"IP Indian J Neurosci"},{"key":"10.25259\/SNI_974_2025\/ref-5","doi-asserted-by":"crossref","first-page":"380","DOI":"10.3171\/2008.10.JNS08993","article-title":"Collagen matrix duraplasty for posterior fossa surgery: Evaluation of surgical technique in 52 adult patients. Clinical article","volume":"111","author":"Narotam","year":"2009","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_974_2025\/ref-6","doi-asserted-by":"crossref","first-page":"45","DOI":"10.3171\/jns.2007.106.1.45","article-title":"Collagen matrix duraplasty for cranial and spinal surgery: A clinical and imaging study","volume":"106","author":"Narotam","year":"2007","journal-title":"J Neurosurg"},{"key":"10.25259\/SNI_974_2025\/ref-7","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.wneu.2011.12.011","article-title":"A multicenter, single-blind, prospective randomized trial to evaluate the safety of a polyethylene glycol hydrogel (Duraseal Dural Sealant System) as a dural sealant in cranial surgery","volume":"78","author":"Osbun","year":"2012","journal-title":"World Neurosurg"},{"key":"10.25259\/SNI_974_2025\/ref-8","doi-asserted-by":"crossref","first-page":"171","DOI":"10.4103\/2152-7806.146154","article-title":"Two alternative dural sealing techniques in posterior fossa surgery: (Polylactide-co-glycolide) self-adhesive resorbable membrane versus polyethylene glycol hydrogel","volume":"5","author":"Schiariti","year":"2014","journal-title":"Surg Neurol Int"},{"key":"10.25259\/SNI_974_2025\/ref-9","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3390\/surgeries2040036","article-title":"A multilayered dural repair technique using duragen for early cranioplasty following decompressive craniotomy","volume":"2","author":"Tamura","year":"2021","journal-title":"Surgeries"},{"key":"10.25259\/SNI_974_2025\/ref-10","first-page":"ONS182","article-title":"Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery","volume":"63","author":"Than","year":"2008","journal-title":"Neurosurgery"}],"container-title":["Surgical Neurology International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/surgicalneurologyint.com\/multilayer-dural-repair-using-absorbable-artificial-dura-in-the-posterior-fossa-a-case-report-on-the-sandwich-technique\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/multilayer-dural-repair-using-absorbable-artificial-dura-in-the-posterior-fossa-a-case-report-on-the-sandwich-technique\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T12:28:42Z","timestamp":1770985722000},"score":1,"resource":{"primary":{"URL":"http:\/\/surgicalneurologyint.com\/surgicalint-articles\/multilayer-dural-repair-using-absorbable-artificial-dura-in-the-posterior-fossa-a-case-report-on-the-sandwich-technique\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,13]]},"references-count":10,"alternative-id":["10.25259\/SNI_974_2025"],"URL":"https:\/\/doi.org\/10.25259\/sni_974_2025","relation":{},"ISSN":["2152-7806","2229-5097"],"issn-type":[{"value":"2152-7806","type":"electronic"},{"value":"2229-5097","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2,13]]},"article-number":"87"}}