{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:51:16Z","timestamp":1790776276814,"version":"4.1.0"},"reference-count":31,"publisher":"International Journal of Sports Physical Therapy","issue":"5","license":[{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec id=\"introduction\">\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Recent technological advancements have enabled medical, sport, and fitness professionals to utilize digital tools that assist with conducting movement examinations and screenings. One such advancement has been the implementation of a single camera, markerless, and portable 3D motion capture system designed to obtain ROM measurements for multiple body parts simultaneously. However, the reliability and validity of a markerless 3D motion capture system that uses a single camera has not been established.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"purpose\">\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study was to investigate the reliability and concurrent validity of this 3D motion capture system compared to a goniometer in assessing ROM of the glenohumeral joint.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"study-design\">\n                    <jats:title>Study Design<\/jats:title>\n                    <jats:p>Quasi-experimental reliability, convenience sampling.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"methodsmaterials\">\n                    <jats:title>Methods\/materials<\/jats:title>\n                    <jats:p>\n                      Forty healthy volunteers (mean \u00b1 SD, age 27.4 \u00b1 12.4 years, height 173.4 \u00b1 11.1 cm, weight 72.1 \u00b1 16.2 kg) participated in this study. Intrarater reliability was analyzed by ICC\n                      <jats:sub>(2,k)<\/jats:sub>\n                      with a 95% CI using two repeated trials for each shoulder movement (flexion, abduction, external rotation, internal rotation) that were recorded simultaneously via two methods: a standard goniometer and a 3D motion capture system. Concurrent validity was analyzed using Pearson Correlation Coefficient (\n                      <jats:italic>r<\/jats:italic>\n                      ).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The intrarater reliability between the two instruments for glenohumeral motions yielded an overall ICC of 0.82 (95% CI: 0.74-0.88) indicating good reliability for both instruments.<\/jats:p>\n                    <jats:p>The 3D motion capture system demonstrated strong correlations with goniometry for shoulder flexion (r = 0.67), abduction (r = 0.63), and external rotation (r = 0.76), and very strong correlation for shoulder internal rotation (r = 0.84).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"conclusion\">\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Results from this study indicated that a markerless, single camera, portable 3D motion capture system can be a reliable and valid tool to assess glenohumeral joint ROM in comparison to a standard goniometer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"level-of-evidence\">\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>3<\/jats:p>\n                  <\/jats:sec>","DOI":"10.26603\/001c.88003","type":"journal-article","created":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T11:30:33Z","timestamp":1696159833000},"source":"Crossref","is-referenced-by-count":12,"title":["Reliability and Concurrent Validity of a Markerless, Single Camera, Portable 3D Motion Capture System for Assessment of Glenohumeral Mobility."],"prefix":"10.26603","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1298-5498","authenticated-orcid":false,"given":"Ofra","family":"Pottorf","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/03pm18j10","id-type":"ROR","asserted-by":"publisher"}],"name":"Hofstra University","department":["Allied Health and Kinesiology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Vapne","sequence":"additional","affiliation":[{"name":"PT Solutions Physical Therapy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamie","family":"Ghigiarelli","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/03pm18j10","id-type":"ROR","asserted-by":"publisher"}],"name":"Hofstra University","department":["Allied Health and Kinesiology"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaitlyn","family":"Haase","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"11140","published-online":{"date-parts":[[2023,10,1]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1097\/00003086-199002000-00046","article-title":"Axial rotation gravity goniometer. A simple design of instrument and a controlled reliability study","volume":"251","author":"WIROON Laupattarakasem","year":"1990","journal-title":"Clinical Orthopaedics and Related Research","ISSN":"https:\/\/id.crossref.org\/issn\/0009-921X","issn-type":"print"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"100131","DOI":"10.1016\/j.medntd.2022.100131","article-title":"Concurrent validity of a markerless motion capture system for the assessment of shoulder functional movement","volume":"15","author":"Bin Chen","year":"2022","journal-title":"Medicine in Novel Technology and Devices","ISSN":"https:\/\/id.crossref.org\/issn\/2590-0935","issn-type":"print"},{"issue":"3","key":"ref3","first-page":"306","article-title":"The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: a technical report","volume":"7","author":"M.J. Kolber","year":"2012","journal-title":"Int J Sports Phys Ther"},{"issue":"10","key":"ref4","doi-asserted-by":"publisher","first-page":"2219","DOI":"10.1016\/j.jbiomech.2014.04.028","article-title":"Validity and reliability of 3D marker based scapular motion analysis: a systematic review","volume":"47","author":"Mathieu Lempereur","year":"2014","journal-title":"Journal of Biomechanics","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"issue":"50","key":"ref5","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2020.00050","article-title":"Evaluation of 3D markerless motion capture accuracy using OpenPose with multiple video cameras","volume":"2","author":"Nobuyasu Nakano","year":"2020","journal-title":"Frontiers in Sports and Active Living","ISSN":"https:\/\/id.crossref.org\/issn\/2624-9367","issn-type":"print"},{"issue":"8","key":"ref6","doi-asserted-by":"publisher","first-page":"2638","DOI":"10.3390\/s18082638","article-title":"Reliability of 3D lower extremity movement analysis by means of inertial sensor technology during transitional tasks","volume":"18","author":"Rob V. Straaten","year":"2018","journal-title":"Sensors","ISSN":"https:\/\/id.crossref.org\/issn\/1424-8220","issn-type":"print"},{"issue":"7","key":"ref7","first-page":"898","article-title":"Quantifying frontal plane knee motion during single limb squats: reliability and validity of 2-dimensional measures","volume":"9","author":"C.R. Gwynne","year":"2014","journal-title":"Int J Sports Phys Ther"},{"issue":"18","key":"ref8","doi-asserted-by":"publisher","first-page":"5342","DOI":"10.3390\/s20185342","article-title":"Fusion of multiple lidars and inertial sensors for the real-time pose tracking of human motion","volume":"20","author":"Ashok Kumar Patil","year":"2020","journal-title":"Sensors","ISSN":"https:\/\/id.crossref.org\/issn\/1424-8220","issn-type":"print"},{"issue":"2","key":"ref9","first-page":"163","article-title":"Two-dimensional video analysis is comparable to 3D motion capture in lower extremity movement assessment","volume":"12","author":"S.A. Schurr","year":"2017","journal-title":"Int J Sports Phys Ther"},{"key":"ref10","article-title":"Kinotek, Inc."},{"key":"ref11","article-title":"Joint Motion and Function Assessment: A Research-Based Practical Guide","author":"H.M. Clarkson","year":"2005"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"e4431","DOI":"10.7717\/peerj.4431","article-title":"Reliability and concurrent validity of the iPhone<sup>\u00ae<\/sup> compass application to measure thoracic rotation range of motion (ROM) in healthy participants","volume":"6","author":"James Furness","year":"2018","journal-title":"PeerJ","ISSN":"https:\/\/id.crossref.org\/issn\/2167-8359","issn-type":"print"},{"issue":"1","key":"ref13","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.jht.2018.03.003","article-title":"The validity and reliability of DrGoniometer, a smartphone application, for measuring forearm supination","volume":"32","author":"Susan Reid","year":"2019","journal-title":"Journal of Hand Therapy","ISSN":"https:\/\/id.crossref.org\/issn\/0894-1130","issn-type":"print"},{"issue":"1","key":"ref14","doi-asserted-by":"publisher","first-page":"62","DOI":"10.3109\/09593985.2013.800174","article-title":"The reliability, minimal detectable change and concurrent validity of a gravity-based bubble inclinometer and iphone application for measuring standing lumbar lordosis","volume":"30","author":"Paul A. Salamh","year":"2014","journal-title":"Physiotherapy Theory and Practice","ISSN":"https:\/\/id.crossref.org\/issn\/0959-3985","issn-type":"print"},{"issue":"4","key":"ref15","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.math.2012.02.010","article-title":"Within-day reliability of shoulder range of motion measurement with a smartphone","volume":"17","author":"Seung Han Shin","year":"2012","journal-title":"Manual Therapy","ISSN":"https:\/\/id.crossref.org\/issn\/1356-689X","issn-type":"print"},{"issue":"8","key":"ref16","doi-asserted-by":"publisher","first-page":"1527","DOI":"10.1016\/j.ajem.2019.03.021","article-title":"Reliability of smartphone measurements of vital parameters: a prospective study using a reference method","volume":"37","author":"\u0130smail Tayfur","year":"2019","journal-title":"The American Journal of Emergency Medicine","ISSN":"https:\/\/id.crossref.org\/issn\/0735-6757","issn-type":"print"},{"key":"ref17","article-title":"Foundations of clinical research: Applications to practice","author":"L.G. Portney","year":"2015","edition":"3rd"},{"key":"ref18","isbn-type":"print","doi-asserted-by":"publisher","DOI":"10.4324\/9780203771587","article-title":"Statistical Power Analysis for the Behavioral Sciences","author":"Jacob Cohen","year":"2013","ISBN":"https:\/\/id.crossref.org\/isbn\/9781134742707"},{"key":"ref19","article-title":"Multivariate Data Analysis","author":"J. Hair","year":"2016"},{"issue":"2","key":"ref20","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research [published correction appears in J Chiropr Med. 2017 Dec;16(4):346]","volume":"15","author":"Terry K. Koo","year":"2016","journal-title":"Journal of Chiropractic Medicine","ISSN":"https:\/\/id.crossref.org\/issn\/1556-3707","issn-type":"print"},{"issue":"2","key":"ref21","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1080\/09593980802686870","article-title":"Effects of age on passive range of motion of selected peripheral joints in healthy adult females","volume":"25","author":"Luciana Gazzi Macedo","year":"2009","journal-title":"Physiotherapy Theory and Practice","ISSN":"https:\/\/id.crossref.org\/issn\/0959-3985","issn-type":"print"},{"issue":"17","key":"ref22","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1136\/bjsports-2019-100698","article-title":"Preseason shoulder range of motion screening and in-season risk of shoulder and elbow injuries in overhead athletes: systematic review and meta-analysis","volume":"54","author":"Federico Pozzi","year":"2020","journal-title":"British Journal of Sports Medicine","ISSN":"https:\/\/id.crossref.org\/issn\/0306-3674","issn-type":"print"},{"issue":"2","key":"ref23","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1080\/10833196.2018.1442829","article-title":"Range of motion measurements in clinical practice: An overview of goniometry and inclinometry","volume":"23","author":"N.R. Hendrickson","year":"2018","journal-title":"Phys Ther Rev"},{"issue":"2","key":"ref24","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1093\/ptj\/71.2.90","article-title":"Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting","volume":"71","author":"Michael A Watkins","year":"1991","journal-title":"Physical Therapy","ISSN":"https:\/\/id.crossref.org\/issn\/0031-9023","issn-type":"print"},{"issue":"3","key":"ref25","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1016\/j.jseint.2022.02.002","article-title":"Reliability and concurrent validity of Mobile Health Technology for patient self-monitoring in physical rehabilitation","volume":"6","author":"Ofra A. Pottorf","year":"2022","journal-title":"JSES International","ISSN":"https:\/\/id.crossref.org\/issn\/2666-6383","issn-type":"print"},{"key":"ref26","article-title":"Measurement of Joint Motion: A Guide to Goniometry","author":"C.C. Norkin","year":"2016"},{"issue":"3","key":"ref27","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1111\/j.1365-2516.2010.02399.x","article-title":"Range of motion measurements: Reference values and a database for comparison studies","volume":"17","author":"J. M. Soucie","year":"2011","journal-title":"Haemophilia","ISSN":"https:\/\/id.crossref.org\/issn\/1351-8216","issn-type":"print"},{"issue":"3","key":"ref28","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1002\/pri.97","article-title":"Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects","volume":"2","author":"Lucie Brosseau","year":"1997","journal-title":"Physiotherapy Research International","ISSN":"https:\/\/id.crossref.org\/issn\/1358-2267","issn-type":"print"},{"issue":"3","key":"ref29","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/s0894-1130(99)80045-3","article-title":"Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation","volume":"12","author":"Joy C. MacDermid","year":"1999","journal-title":"Journal of Hand Therapy","ISSN":"https:\/\/id.crossref.org\/issn\/0894-1130","issn-type":"print"},{"issue":"3","key":"ref30","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.physio.2009.12.002","article-title":"Reliability of physical examination tests used in the assessment of patients with shoulder problems: a systematic review","volume":"96","author":"Stephen May","year":"2010","journal-title":"Physiotherapy","ISSN":"https:\/\/id.crossref.org\/issn\/0031-9406","issn-type":"print"},{"issue":"12","key":"ref31","doi-asserted-by":"publisher","first-page":"1867","DOI":"10.1093\/ptj\/67.12.1867","article-title":"Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity","volume":"67","author":"Richard L. Gajdosik","year":"1987","journal-title":"Physical Therapy","ISSN":"https:\/\/id.crossref.org\/issn\/0031-9023","issn-type":"print"}],"container-title":["International Journal of Sports Physical Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/ijspt.scholasticahq.com\/article\/88003-reliability-and-concurrent-validity-of-a-markerless-single-camera-portable-3d-motion-capture-system-for-assessment-of-glenohumeral-mobility","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T14:50:30Z","timestamp":1790175030000},"score":1,"resource":{"primary":{"URL":"https:\/\/ijspt.scholasticahq.com\/article\/88003-reliability-and-concurrent-validity-of-a-markerless-single-camera-portable-3d-motion-capture-system-for-assessment-of-glenohumeral-mobility"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,1]]},"references-count":31,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.26603\/001c.88003","relation":{},"ISSN":["2159-2896"],"issn-type":[{"value":"2159-2896","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,1]]}}}