{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T15:03:48Z","timestamp":1785423828908,"version":"3.56.0"},"reference-count":20,"publisher":"Canadian Society of Respiratory Therapists","license":[{"start":{"date-parts":[[2025,4,15]],"date-time":"2025-04-15T00:00:00Z","timestamp":1744675200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec id=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Aerosol drug delivery is widely used in treating respiratory conditions, but the patient\u2019s breathing pattern can significantly influence its effectiveness. This study investigates the impact of normal, obstructive, and restrictive breathing patterns on aerosol drug delivery with jet and mesh nebulizers in a simulated model of spontaneously breathing adults.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A spontaneously breathing adult was simulated using a teaching manikin (Nasco Healthcare) connected to a breathing simulator (QuickLung Breather; IngMar Medical Inc). A collecting filter (CareFusion) was placed distal to the bifurcation of the mainstem bronchi and connected to the breathing simulator. Albuterol sulfate (2.5 mg\/3 mL) was delivered with jet (MistyMax 10) and mesh nebulizers (Aerogen Ultra). Each experiment was conducted in triplicate (n = 3), comparing drug delivery across six breathing patterns: (1) normal, (2) moderate obstruction, (3) severe obstruction, (4) moderate restriction, (5) severe restriction, and (6) combined obstruction and restriction. Data analysis included the Friedman ANOVA, uncorrected Dunn\u2019s test, and paired t-tests with Holm-Sidak\u2019s multiple comparison test (GraphPad Prism 10.3), with statistical significance set at\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Our findings indicate that obstructive, restrictive, and combined breathing patterns significantly reduce aerosol deposition with jet and mesh nebulizers compared to normal breathing (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05). Aerosol delivery with the mesh nebulizer was up to 3-fold more than the jet nebulizer regardless of the breathing pattern tested in this study (\n                      <jats:italic>p<\/jats:italic>\n                      &lt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"conclusions\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study highlights the necessity for tailored aerosol therapy strategies to optimize drug delivery in patients with different respiratory conditions..<\/jats:p>\n                  <\/jats:sec>","DOI":"10.29390\/001c.134080","type":"journal-article","created":{"date-parts":[[2025,4,15]],"date-time":"2025-04-15T08:36:11Z","timestamp":1744706171000},"source":"Crossref","is-referenced-by-count":0,"title":["Impact of normal, obstructive, and restrictive breathing patterns on aerosol drug delivery with jet and mesh nebulizers in simulated spontaneously breathing adults"],"prefix":"10.29390","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3126-8144","authenticated-orcid":true,"given":"Arzu","family":"Ari","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/05h9q1g27","id-type":"ROR","asserted-by":"publisher"}],"name":"Texas State University","department":["Respiratory Care"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jordan A.","family":"Hoops","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/05h9q1g27","id-type":"ROR","asserted-by":"publisher"}],"name":"Texas State University","department":["Respiratory Care"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zari","family":"Williams","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/015yf2b46","id-type":"ROR","asserted-by":"publisher"}],"name":"Dell Children's Medical Center of Central Texas","department":["Respiratory Care"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James B.","family":"Fink","sequence":"additional","affiliation":[{"name":"Aerogen Pharma"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"11956","published-online":{"date-parts":[[2025,4,15]]},"reference":[{"issue":"3","key":"ref1","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1089\/jamp.2021.29036.csk","article-title":"Physiological factors affecting lung deposition","volume":"34","author":"C. S. Kim","year":"2021","journal-title":"J Aerosol Med Pulm Drug Deliv"},{"issue":"3","key":"ref2","doi-asserted-by":"publisher","first-page":"328","DOI":"10.4187\/respcare.02291","article-title":"Scintigraphic assessment of radio-aerosol pulmonary deposition with the acapella positive expiratory pressure device and various nebulizer configurations","volume":"59","author":"F. O. S. Mesquita","year":"2014","journal-title":"Respir Care"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"S6","DOI":"10.1089\/jamp.2012.1Su3","article-title":"Validation of radiolabeling of drug formulations for aerosol deposition assessment of orally inhaled products","volume":"25 Suppl 1","author":"S. G. Devadason","year":"2012","journal-title":"J Aerosol Med Pulm Drug Deliv"},{"issue":"1","key":"ref4","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1053\/j.semnuclmed.2018.10.014","article-title":"Studies of radioaerosol deposition in the respiratory tract","volume":"49","author":"P. C. L. Kwok","year":"2019","journal-title":"Semin Nucl Med"},{"issue":"3","key":"ref5","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1089\/jamp.2010.0845","article-title":"Comparing lung regions of interest in gamma scintigraphy for assessing inhaled therapeutic aerosol deposition","volume":"24","author":"M. F. Biddiscombe","year":"2011","journal-title":"J Aerosol Med Pulm Drug Deliv"},{"issue":"1","key":"ref6","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1053\/j.semnuclmed.2018.10.015","article-title":"Lung scintigraphy in the assessment of aerosol deposition and clearance","volume":"49","author":"A. Sanchez-Crespo","year":"2019","journal-title":"Semin Nucl Med"},{"issue":"5","key":"ref7","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1089\/jamp.2017.1366","article-title":"Aerosol delivery with two nebulizers through high-flow nasal cannula: A randomized cross-over single-photon emission computed tomography-computed tomography study","volume":"30","author":"J. Dugernier","year":"2017","journal-title":"J Aerosol Med Pulm Drug Deliv"},{"issue":"5","key":"ref8","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1089\/jamp.2021.29045.wdb","article-title":"Effect of respiratory tract disease on particle deposition","volume":"34","author":"W. D. Bennett","year":"2021","journal-title":"J Aerosol Med Pulm Drug Deliv"},{"issue":"1","key":"ref9","doi-asserted-by":"publisher","first-page":"5720","DOI":"10.1038\/s41598-019-42103-2","article-title":"Development of an ex vivo respiratory pediatric model of bronchopulmonary dysplasia for aerosol deposition studies","volume":"9","author":"Y. Montigaud","year":"2019","journal-title":"Scientific Reports"},{"key":"ref10","series-title":"Mosby's respiratory care equipment","article-title":"Humidity and aerosol devices","author":"A. Ari","year":"2021","edition":"11"},{"issue":"2","key":"ref11","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1089\/jamp.2015.1270","article-title":"Bridging the gap between science and clinical efficacy: Physiology, imaging, and modeling of aerosols in the lung","volume":"29","author":"C. Darquenne","year":"2016","journal-title":"J Aerosol Med Pulm Drug Deliv"},{"issue":"2","key":"ref12","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1089\/jamp.2019.1552","article-title":"Maximizing deep lung deposition in healthy and fibrotic subjects during jet nebulization. [published correction appears in J Aerosol Med Pulm Drug Deliv. 2020 Jun;33(3):170. doi: 10.1089\/jamp.2020.29030.correx]","volume":"33","author":"J. Samuel","year":"2020"},{"issue":"3","key":"ref13","first-page":"310","article-title":"Frequency and causes of combined obstruction and restriction identified in pulmonary function tests in adults","volume":"55","author":"E. Diaz-Guzman","year":"2010","journal-title":"Respir Care"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"542769","DOI":"10.1155\/2012\/542769","article-title":"Lung compliance and chronic obstructive pulmonary disease","volume":"2012","author":"D. Papandrinopoulou","year":"2012","journal-title":"Pulm Med"},{"issue":"12","key":"ref15","doi-asserted-by":"publisher","first-page":"3639","DOI":"10.21037\/jtd.2016.12.64","article-title":"A bench evaluation of fraction of oxygen in air delivery and tidal volume accuracy in home care ventilators available for hospital use","volume":"8","author":"L. Baboi","year":"2016","journal-title":"J Thorac Dis"},{"issue":"3","key":"ref16","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1378\/chest.08-1340","article-title":"Intentional leaks in industrial masks have a significant impact on efficacy of bilevel noninvasive ventilation","volume":"135","author":"J. C. Borel","year":"2009","journal-title":"Chest"},{"issue":"11","key":"ref17","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.4187\/respcare.02144","article-title":"Evaluation of ventilators used during transport of critically ill patients: A bench study","volume":"58","author":"S. Boussen","year":"2013","journal-title":"Respir Care"},{"issue":"12","key":"ref18","doi-asserted-by":"publisher","first-page":"1555","DOI":"10.4187\/respcare.06422","article-title":"Accuracy of the ventilator automated displayed respiratory mechanics in passive and active breathing conditions: A bench study","volume":"64","author":"E. G. Daoud","year":"2019","journal-title":"Respir Care"},{"issue":"6","key":"ref19","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1007\/s10877-023-01019-z","article-title":"Are all ventilators for niv performing the same? A bench analysis","volume":"37","author":"S. Martinez-Castro","year":"2023","journal-title":"J Clin Monit Comput"},{"issue":"9","key":"ref20","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.4187\/respcare.07280","article-title":"Double-triggering during noninvasive ventilation in a simulated lung model","volume":"65","author":"R. D. Sheehy","year":"2020","journal-title":"Respir Care"}],"container-title":["Canadian Journal of Respiratory Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/cjrt.ca\/article\/134080-impact-of-normal-obstructive-and-restrictive-breathing-patterns-on-aerosol-drug-delivery-with-jet-and-mesh-nebulizers-in-simulated-spontaneously-bre","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T15:20:47Z","timestamp":1761751247000},"score":1,"resource":{"primary":{"URL":"https:\/\/cjrt.ca\/article\/134080-impact-of-normal-obstructive-and-restrictive-breathing-patterns-on-aerosol-drug-delivery-with-jet-and-mesh-nebulizers-in-simulated-spontaneously-bre"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,15]]},"references-count":20,"URL":"https:\/\/doi.org\/10.29390\/001c.134080","relation":{},"ISSN":["2368-6820"],"issn-type":[{"value":"2368-6820","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,15]]}}}