{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T08:30:29Z","timestamp":1776501029065,"version":"3.51.2"},"reference-count":35,"publisher":"Society of Nuclear Medicine","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Nucl Med"],"published-print":{"date-parts":[[2010,10]]},"DOI":"10.2967\/jnumed.110.078352","type":"journal-article","created":{"date-parts":[[2010,9,17]],"date-time":"2010-09-17T03:46:09Z","timestamp":1284695169000},"page":"1624-1631","source":"Crossref","is-referenced-by-count":77,"title":["Multicenter Evaluation of a Standardized Protocol for Rest and Acetazolamide Cerebral Blood Flow Assessment Using a Quantitative SPECT Reconstruction Program and Split-Dose <sup>123<\/sup>I-Iodoamphetamine"],"prefix":"10.2967","volume":"51","author":[{"given":"Hidehiro","family":"Iida","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jyoji","family":"Nakagawara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohei","family":"Hayashida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhito","family":"Fukushima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Watabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhiro","family":"Koshino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsutomu","family":"Zeniya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Eberl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1602","published-online":{"date-parts":[[2010,9,16]]},"reference":[{"key":"2021051712005809000_51.10.1624.1","doi-asserted-by":"publisher","DOI":"10.1097\/00004647-199609000-00003"},{"key":"2021051712005809000_51.10.1624.2","first-page":"1102","article-title":"Regional cerebral blood flow measurement with iodine-123-IMP autoradiography: normal values, reproducibility and sensitivity to hypoperfusion","volume":"38","author":"Hatazawa","year":"1997","journal-title":"J Nucl Med."},{"key":"2021051712005809000_51.10.1624.3","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1161\/01.STR.17.6.1220","article-title":"Reduction in regional cerebral metabolic rate of oxygen during human aging","volume":"17","author":"Yamaguchi","year":"1986","journal-title":"Stroke."},{"key":"2021051712005809000_51.10.1624.4","first-page":"520","article-title":"Quantitative measurement of regional cerebrovascular reactivity to acetazolamide using 123I-N-isopropyl-p-iodoamphetamine autoradiography with SPECT: validation study using H2\n               15O with PET","volume":"44","author":"Ogasawara","year":"2003","journal-title":"J Nucl Med."},{"key":"2021051712005809000_51.10.1624.5","doi-asserted-by":"publisher","DOI":"10.1097\/00004647-200209000-00012"},{"key":"2021051712005809000_51.10.1624.6","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000019511.81583.A8"},{"issue":"suppl 7","key":"2021051712005809000_51.10.1624.7","first-page":"524","article-title":"JET study (Japanese EC-IC Bypass Trial) [in Japanese]","volume":"64","author":"Ogasawara","year":"2006","journal-title":"Nippon Rinsho."},{"key":"2021051712005809000_51.10.1624.8","doi-asserted-by":"publisher","DOI":"10.1002\/ana.20688"},{"key":"2021051712005809000_51.10.1624.9","doi-asserted-by":"publisher","DOI":"10.1007\/BF02988446"},{"key":"2021051712005809000_51.10.1624.10","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-007-0654-4"},{"key":"2021051712005809000_51.10.1624.11","doi-asserted-by":"publisher","DOI":"10.1016\/S1071-3581(98)90133-7"},{"key":"2021051712005809000_51.10.1624.12","doi-asserted-by":"publisher","DOI":"10.1007\/s002590100586"},{"key":"2021051712005809000_51.10.1624.13","doi-asserted-by":"publisher","DOI":"10.1109\/NSSMIC.2004.1466353"},{"key":"2021051712005809000_51.10.1624.14","doi-asserted-by":"publisher","DOI":"10.1118\/1.597605"},{"key":"2021051712005809000_51.10.1624.15","doi-asserted-by":"publisher","DOI":"10.1067\/mnc.2002.120680"},{"key":"2021051712005809000_51.10.1624.16","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-004-1495-z"},{"key":"2021051712005809000_51.10.1624.17","doi-asserted-by":"publisher","DOI":"10.1109\/42.363108"},{"key":"2021051712005809000_51.10.1624.18","first-page":"360","article-title":"A transmission-dependent method for scatter correction in SPECT","volume":"35","author":"Meikle","year":"1994","journal-title":"J Nucl Med."},{"key":"2021051712005809000_51.10.1624.19","first-page":"181","article-title":"Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT","volume":"39","author":"Iida","year":"1998","journal-title":"J Nucl Med."},{"key":"2021051712005809000_51.10.1624.20","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/41\/11\/017"},{"key":"2021051712005809000_51.10.1624.21","doi-asserted-by":"publisher","DOI":"10.1109\/23.656453"},{"key":"2021051712005809000_51.10.1624.22","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/12\/002"},{"key":"2021051712005809000_51.10.1624.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2006.06.064"},{"key":"2021051712005809000_51.10.1624.24","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1109\/23.940148","article-title":"SPECT collimator dependency of scatter and validation of transmission dependent scatter compensation methodologies","volume":"48","author":"Kim","year":"2001","journal-title":"IEEE Trans Nucl Sci."},{"key":"2021051712005809000_51.10.1624.25","first-page":"2019","article-title":"Quantitative mapping of regional cerebral blood flow using iodine-123-IMP and SPECT","volume":"35","author":"Iida","year":"1994","journal-title":"J Nucl Med."},{"key":"2021051712005809000_51.10.1624.26","first-page":"263","article-title":"Quantitation of regional cerebral blood flow using 123I-IMP from a single SPECT scan and a single blood sampling: analysis on statistical error source and optimal scan time [in Japanese]","volume":"32","author":"Iida","year":"1995","journal-title":"Kaku Igaku."},{"key":"2021051712005809000_51.10.1624.27","first-page":"13","article-title":"Estimation and optimization of the use of standard arterial input function for split-dose administration of N-isopropyl-p[123I]iodoamphetamine [in Japanese]","volume":"39","author":"Kurisu","year":"2002","journal-title":"Kaku Igaku."},{"key":"2021051712005809000_51.10.1624.28","first-page":"879","article-title":"Validation and optimization of the use of standardized arterial input function in N-isopropyl-p[123I]iodoamphetamine cerebral blood flow SPECT [in Japanese]","volume":"36","author":"Ogura","year":"1999","journal-title":"Kaku Igaku."},{"key":"2021051712005809000_51.10.1624.29","doi-asserted-by":"publisher","DOI":"10.1007\/BF02988616"},{"key":"2021051712005809000_51.10.1624.30","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1038\/jcbfm.1988.60","article-title":"Evaluation of regional differences of tracer appearance time in cerebral tissues using [15O] water and dynamic positron emission tomography","volume":"8","author":"Iida","year":"1988","journal-title":"J Cereb Blood Flow Metab."},{"key":"2021051712005809000_51.10.1624.31","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1038\/jcbfm.1986.99","article-title":"Error analysis of a quantitative cerebral blood flow measurement using H2\n               15O autoradiography and positron emission tomography, with respect to the dispersion of the input function","volume":"6","author":"Iida","year":"1986","journal-title":"J Cereb Blood Flow Metab."},{"key":"2021051712005809000_51.10.1624.32","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1038\/jcbfm.1989.121","article-title":"A determination of the regional brain\/blood partition coefficient of water using dynamic positron emission tomography","volume":"9","author":"Iida","year":"1989","journal-title":"J Cereb Blood Flow Metab."},{"key":"2021051712005809000_51.10.1624.33","doi-asserted-by":"publisher","DOI":"10.1109\/23.775605"},{"key":"2021051712005809000_51.10.1624.34","first-page":"83","article-title":"Scatter correction in myocardial thallium SPECT: needs for optimization of energy window settings in the energy window-based scatter correction techniques [in Japanese]","volume":"36","author":"Narita","year":"1999","journal-title":"Kaku Igaku."},{"key":"2021051712005809000_51.10.1624.35","first-page":"137","article-title":"Automated interstudy image registration technique for SPECT and PET","volume":"37","author":"Eberl","year":"1996","journal-title":"J Nucl Med."}],"container-title":["Journal of Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.2967\/jnumed.110.078352","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,17]],"date-time":"2021-05-17T19:26:43Z","timestamp":1621279603000},"score":1,"resource":{"primary":{"URL":"http:\/\/jnm.snmjournals.org\/lookup\/doi\/10.2967\/jnumed.110.078352"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,9,16]]},"references-count":35,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2010,10,1]]},"published-print":{"date-parts":[[2010,10]]}},"alternative-id":["10.2967\/jnumed.110.078352"],"URL":"https:\/\/doi.org\/10.2967\/jnumed.110.078352","relation":{},"ISSN":["0161-5505","2159-662X"],"issn-type":[{"value":"0161-5505","type":"print"},{"value":"2159-662X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,9,16]]}}}