{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T08:48:56Z","timestamp":1776329336178,"version":"3.50.1"},"reference-count":0,"publisher":"Universidad Nacional de C\u00f3rdoba","issue":"1","license":[{"start":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T00:00:00Z","timestamp":1743379200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rev Fac Cien Med Univ Nac Cordoba"],"abstract":"<jats:p>Introduction: Self-adjusting titration (APAP) at home is accepted to define therapeutic pressure (CPAPT). The APAP device report may be insufficient to ensure adequate therapeutic response in all patients. There is no consensus on the use of oximetry during APAP titration.\r\nObjective: To evaluate the prevalence and magnitude of residual hypoxemia (RH) in titration with APAP not monitored at home and to identify related variables.\r\nMaterials and Methods: Retrospective study based on APAP titrations with coupled oximetry, arterial blood gases and spirometry test. A T90 &gt; 10% of the night was considered significant RH. Predictors of HR were identified by logistic regression (RL).\r\nResults: 116 cases were included. 41% in the group with RH. These were older (66.7 vs. 59.6 years, p: 0.02), lower absolute FEV1 (2.17 vs. 2.57 liters, p: 0.06), lower absolute FVC (2.9 vs. 3.3 liters, p: 0.02) and lower basal PO2 (77.3 vs. 84.2 mmHg, p: 0.04). The titration period reached 3.6 \u00b1 1 nights, average adherence of 374 \u00b1 88.4 minutes\/night; CPAPT (cm H2O): 9.4 \u00b1 1.8, AHIr; 3.1 \u00b1 3.2 ev\/h and leaks (liters\/min): 19.7 \u00b1 11.2. Multiple logistic regression identified age &gt; 66 years as a predictor of RH (OR 3.32, 95% CI 1.43 - 7.69, p: 0.005) and FEV1 &lt; 1.76 liters (OR 3.29 \u2013 IC95% 1.27 \u2013 8.53, p: 0.0139).\u00a0\r\nConclusions: Incompletely corrected nocturnal oximetry was observed in a significant proportion of patients with APAP. Age over 66 years and absolute FEV1 &lt; 1.76 liters were correlated with residual hypoxemia.<\/jats:p>","DOI":"10.31053\/1853.0605.v82.n1.44671","type":"journal-article","created":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T15:16:43Z","timestamp":1743434203000},"page":"61-77","source":"Crossref","is-referenced-by-count":0,"title":["Hipoxemia residual durante la titulaci\u00f3n con CPAP autoajustable en domicilio en pacientes sin adaptaci\u00f3n previa","Residual hypoxemia during titration with self-adjusting CPAP at home in patients without prior adaptation.","Hipoxemia residual durante titula\u00e7\u00e3o com CPAP autoajust\u00e1vel em domicilio em pacientes sem adapta\u00e7\u00e3o pr\u00e9via."],"prefix":"10.31053","volume":"82","author":[{"given":"Julieta","family":"Franzoy","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magali","family":"Blanco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Glenda","family":"Ernst","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Belen","family":"Ginetti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcella","family":"Perri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eduardo","family":"Borsini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"12333","published-online":{"date-parts":[[2025,3,31]]},"container-title":["Revista de la Facultad de Ciencias M\u00e9dicas de C\u00f3rdoba"],"original-title":[],"link":[{"URL":"http:\/\/revistas.unc.edu.ar\/index.php\/med\/article\/download\/44671\/48667","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/revistas.unc.edu.ar\/index.php\/med\/article\/download\/44671\/48624","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/revistas.unc.edu.ar\/index.php\/med\/article\/download\/44671\/48667","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T15:16:44Z","timestamp":1743434204000},"score":1,"resource":{"primary":{"URL":"http:\/\/revistas.unc.edu.ar\/index.php\/med\/article\/view\/44671"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,31]]},"references-count":0,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,3,31]]}},"URL":"https:\/\/doi.org\/10.31053\/1853.0605.v82.n1.44671","relation":{},"ISSN":["1853-0605","0014-6722"],"issn-type":[{"value":"1853-0605","type":"electronic"},{"value":"0014-6722","type":"print"}],"subject":[],"published":{"date-parts":[[2025,3,31]]}}}