{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T23:11:13Z","timestamp":1790637073499,"version":"4.1.0"},"reference-count":28,"publisher":"IMR Press","issue":"2","license":[{"start":{"date-parts":[[2022,3,22]],"date-time":"2022-03-22T00:00:00Z","timestamp":1647907200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Integr. Neurosci."],"abstract":"<jats:p>This study aims to detect whether the optic nerve sheath diameter (ONSD) can be used to dynamically monitor intracranial pressure (ICP). Adult patients undergoing invasive ICP monitoring on the day of admission are included in this study. For each patient, the ONSD is first measured in the supine position and then in the 30\u2218 head-up position. Subsequently, a dynamic test is conducted on 16 patients. The ONSD is measured in the supine position once a day for three consecutive days starting on the day of admission. There is a strong correlation between the ONSD and ICP values in the supine position on admission (r = 0.799), and when patients are changed from the supine to the 30\u2218 head-up position, the ICP and ONSD values decrease correspondingly. However, the change in ICP is not strongly correlated with the change in ONSD (r = 0.358). In the dynamic test, a good agreement between the ICP and ONSD only exists in three patients (18.8%), and three patients have completely different profiles for ICP and ONSD. These results suggest that the changes in the ONSD and ICP values are not closely correlated after dynamic observation. Therefore, measurement of the ONSD may not be a suitable tool to dynamically monitor ICP.<\/jats:p>","DOI":"10.31083\/j.jin2102054","type":"journal-article","created":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T07:59:22Z","timestamp":1648799962000},"source":"Crossref","is-referenced-by-count":16,"title":["Can optic nerve sheath diameter assessment be used as a non-invasive tool to dynamically monitor intracranial pressure?"],"prefix":"10.31083","volume":"21","author":[{"given":"Guo-Biao","family":"Wu","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, the Second Hospital of Hebei Medical University, 050000 Shijiazhuang, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Tian","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Shijiazhuang People\u2019s Hospital, 050000 Shijiazhuang, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao-Bing","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, The Third Hospital of Hebei Medical University, 050000 Shijiazhuang, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi-Yong","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Critical Care medicine, The Third Hospital of Hebei Medical University, 050000 Shijiazhuang, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian-Ying","family":"Guo","sequence":"first","affiliation":[{"name":"Department of Critical Care medicine, The Third Hospital of Hebei Medical University, 050000 Shijiazhuang, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"16242","published-online":{"date-parts":[[2022,3,22]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","unstructured":"Chen L, Wang L, Hu Y, Jiang X, Wang Y, Xing Y. Ultrasonic measurement of optic nerve sheath diameter: a non-invasive surrogate approach for dynamic, real-time evaluation of intracranial pressure. British Journal of Ophthalmology. 2019; 103: 437\u2013441.","DOI":"10.1136\/bjophthalmol-2018-312934"},{"key":"ref2","doi-asserted-by":"crossref","unstructured":"Jimenez Restrepo JN, Le\u00f3n OJ, Quevedo Florez LA. Ocular Ultrasonography: A Useful Instrument in Patients with Trauma Brain Injury in Emergency Service. Emergency Medicine International. 2019; 2019: 9215853.","DOI":"10.1155\/2019\/9215853"},{"key":"ref3","doi-asserted-by":"crossref","unstructured":"Fernando SM, Tran A, Cheng W, Rochwerg B, Taljaard M, Kyeremanteng K, et al. Diagnosis of elevated intracranial pressure in critically ill adults: systematic review and meta-analysis. BMJ. 2019; 366: l4225.","DOI":"10.1136\/bmj.l4225"},{"key":"ref4","doi-asserted-by":"crossref","unstructured":"Munawar K, Khan MT, Hussain SW, Qadeer A, Shad ZS, Bano S, et al. Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound. Cureus Journal of Medical Science. 2019; 11: e4145.","DOI":"10.7759\/cureus.4145"},{"key":"ref5","doi-asserted-by":"crossref","unstructured":"Harary M, Dolmans RGF, Gormley WB: Intracranial Pressure Monitoring-Review and Avenues for Development. Sensors. 2018; 18: 465.","DOI":"10.3390\/s18020465"},{"key":"ref6","doi-asserted-by":"crossref","unstructured":"Nag DS, Sahu S, Swain A, Kant S. Intracranial pressure monitoring: Gold standard and recent innovations. World Journal of Clinical Cases. 2019; 7: 1535\u20131553.","DOI":"10.12998\/wjcc.v7.i13.1535"},{"key":"ref7","doi-asserted-by":"crossref","unstructured":"Robba C, Cardim D, Tajsic T, Pietersen J, Bulman M, Donnelly J, et al. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study. PLoS Medicine. 2017; 14: e1002356.","DOI":"10.1371\/journal.pmed.1002356"},{"key":"ref8","doi-asserted-by":"crossref","unstructured":"Canac N, Jalaleddini K, Thorpe SG, Thibeault CM, Hamilton RB. Review: pathophysiology of intracranial hypertension and noninvasive intracranial pressure monitoring. Fluids and Barriers of the CNS. 2020; 17: 40.","DOI":"10.1186\/s12987-020-00201-8"},{"key":"ref9","doi-asserted-by":"crossref","unstructured":"Robba C, Bacigaluppi S, Cardim D, Donnelly J, Bertuccio A, Czosnyka M. Non-invasive assessment of intracranial pressure. Acta Neurologica Scandinavica. 2016; 134: 4\u201321.","DOI":"10.1111\/ane.12527"},{"key":"ref10","doi-asserted-by":"crossref","unstructured":"Couret D, Boumaza D, Grisotto C, Triglia T, Pellegrini L, Ocquidant P, et al. Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study. Critical Care. 2016; 20: 99.","DOI":"10.1186\/s13054-016-1239-z"},{"key":"ref11","doi-asserted-by":"crossref","unstructured":"Robba C, Pozzebon S, Moro B, Vincent J, Creteur J, Taccone FS. Multimodal non-invasive assessment of intracranial hypertension: an observational study. Critical Care. 2020; 24: 379.","DOI":"10.1186\/s13054-020-03105-z"},{"key":"ref12","doi-asserted-by":"crossref","unstructured":"Zoerle T, Caccioppola A, D\u2019Angelo E, Carbonara M, Conte G, Avignone S, et al. Optic Nerve Sheath Diameter is not Related to Intracranial Pressure in Subarachnoid Hemorrhage Patients. Neurocritical Care. 2020; 33: 491\u2013498.","DOI":"10.1007\/s12028-020-00970-y"},{"key":"ref13","doi-asserted-by":"crossref","unstructured":"Robba C, Santori G, Czosnyka M, Corradi F, Bragazzi N, Padayachy L, et al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Medicine. 2018; 44: 1284\u20131294.","DOI":"10.1007\/s00134-018-5305-7"},{"key":"ref14","doi-asserted-by":"crossref","unstructured":"Hylkema C. Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure. Critical Care Nursing Clinics of North America. 2016; 28: 95\u201399.","DOI":"10.1016\/j.cnc.2015.10.005"},{"key":"ref15","doi-asserted-by":"crossref","unstructured":"Morgan WH, Balaratnasingam C, Lind CRP, Colley S, Kang MH, House PH, et al. Cerebrospinal fluid pressure and the eye. The British Journal of Ophthalmology. 2016; 100: 71\u201377.","DOI":"10.1136\/bjophthalmol-2015-306705"},{"key":"ref16","doi-asserted-by":"crossref","unstructured":"Hanafi MG, Verki MM, Parei SN. Ultrasonic Assessment of Optic Nerve Sheath to Detect Increased Intracranial Pressure. Journal of Medical Ultrasound. 2019; 27: 69\u201374.","DOI":"10.4103\/JMU.JMU_54_18"},{"key":"ref17","doi-asserted-by":"crossref","unstructured":"Kavi T, Gupta A, Hunter K, Schreiber C, Shaikh H, Turtz AR. Optic Nerve Sheath Diameter Assessment in Patients with Intracranial Pressure Monitoring. Cureus Journal of Medical Science. 2018; 10: e3546.","DOI":"10.7759\/cureus.3546"},{"key":"ref18","doi-asserted-by":"crossref","unstructured":"Ertl M, Barinka F, Torka E, Altmann M, Pfister K, Helbig H, et al. Ocular color-coded sonography - a promising tool for neurologists and intensive care physicians. Ultraschall in Der Medizin. 2014; 35: 422\u2013431.","DOI":"10.1055\/s-0034-1366113"},{"key":"ref19","doi-asserted-by":"crossref","unstructured":"Du J, Deng Y, Li H, Qiao S, Yu M, Xu Q, et al. Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasound Can Predict Intracranial Hypertension in Traumatic Brain Injury Patients: a Prospective Study. Neurocritical Care. 2020; 32: 478\u2013485.","DOI":"10.1007\/s12028-019-00762-z"},{"key":"ref20","doi-asserted-by":"crossref","unstructured":"Wang LJ, Chen LM, Chen Y, Bao LY, Zheng NN, Wang YZ, et al. Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure. JAMA Ophthalmology. 2018; 136: 250\u2013256.","DOI":"10.1001\/jamaophthalmol.2017.6560"},{"key":"ref21","doi-asserted-by":"crossref","unstructured":"Cardim D, Griesdale DE, Ainslie PN, Robba C, Calviello L, Czosnyka M, et al. A comparison of non-invasive versus invasive measures of intracranial pressure in hypoxic ischaemic brain injury after cardiac arrest. Resuscitation. 2019; 137: 221\u2013228.","DOI":"10.1016\/j.resuscitation.2019.01.002"},{"key":"ref22","doi-asserted-by":"crossref","unstructured":"Robba C, Donnelly J, Cardim D, Tajsic T, Cabeleira M, Citerio G, et al. Optic nerve sheath diameter ultrasonography at admission as a predictor of intracranial hypertension in traumatic brain injured patients: a prospective observational study. Journal of Neurosurgery. 2019; 132: 1279-1285.","DOI":"10.3171\/2018.11.JNS182077"},{"key":"ref23","doi-asserted-by":"crossref","unstructured":"Montorfano L, Yu Q, Bordes SJ, Sivanushanthan S, Rosenthal RJ, Montorfano M. Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis. The Ultrasound Journal. 2021; 13: 35.","DOI":"10.1186\/s13089-021-00235-5"},{"key":"ref24","doi-asserted-by":"crossref","unstructured":"Rolighed Larsen JK, Haure P, Cold GE. Reverse Trendelenburg position reduces intracranial pressure during craniotomy. Journal of Neurosurgical Anesthesiology. 2002; 14: 16\u201321.","DOI":"10.1097\/00008506-200201000-00004"},{"key":"ref25","doi-asserted-by":"crossref","unstructured":"Kerscher SR, Sch\u00f6ni D, Neunhoeffer F, Wolff M, Haas-Lude K, Bevot A, et al. The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - Part II: Influence of wakefulness, method of ICP measurement, intra-individual ONSD-ICP correlation and changes after therapy. Child\u2019s Nervous System. 2020; 36: 107\u2013115.","DOI":"10.1007\/s00381-019-04336-4"},{"key":"ref26","doi-asserted-by":"crossref","unstructured":"B\u00e4uerle J, Niesen W, Egger K, Buttler K, Reinhard M. Enlarged Optic Nerve Sheath in Aneurysmal Subarachnoid Hemorrhage despite Normal Intracranial Pressure. Journal of Neuroimaging. 2016; 26: 194\u2013196.","DOI":"10.1111\/jon.12287"},{"key":"ref27","doi-asserted-by":"crossref","unstructured":"Hansen H, Lagr\u00e8ze W, Krueger O, Helmke K. Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure - an experimental ultrasound study. Acta Ophthalmologica. 2011; 89: e528\u2013e532.","DOI":"10.1111\/j.1755-3768.2011.02159.x"},{"key":"ref28","doi-asserted-by":"crossref","unstructured":"Yanamandra U, Gupta A, Bhattachar SA, Yanamandra S, Das SK, Patyal S, et al. Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach. Indian Journal of Critical Care Medicine. 2018; 22: 150\u2013153.","DOI":"10.4103\/ijccm.IJCCM_498_17"}],"container-title":["Journal of Integrative Neuroscience"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.imrpress.com\/journal\/JIN\/21\/2\/10.31083\/j.jin2102054","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T15:29:45Z","timestamp":1732721385000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.imrpress.com\/journal\/JIN\/21\/2\/10.31083\/j.jin2102054"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,22]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"alternative-id":["S0219-6352(22)00314-X"],"URL":"https:\/\/doi.org\/10.31083\/j.jin2102054","relation":{},"ISSN":["0219-6352","1757-448X"],"issn-type":[{"value":"0219-6352","type":"print"},{"value":"1757-448X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,22]]},"article-number":"54"}}