{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T23:58:55Z","timestamp":1783468735983,"version":"3.55.0"},"reference-count":25,"publisher":"IMR Press","issue":"4","license":[{"start":{"date-parts":[[2024,3,28]],"date-time":"2024-03-28T00:00:00Z","timestamp":1711584000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rev. Cardiovasc. Med."],"abstract":"<jats:p>It has been rarely reported that a stuck optical coherence tomography (OCT) catheter can lead to longitudinal stent deformation (LSD). This complication can result in incomplete stent apposition and dissection after stent implantation. In this study, we present a case where a bailout stent was implanted in the distal segment of the left anterior descending artery (LAD) after longitudinal stent deformation caused by a stuck OCT catheter. This approach was taken to prevent acute stent thrombosis, subacute stent thrombosis, in-stent restenosis (ISR), and death. The patients were followed up for one year, and no adverse events were observed.<\/jats:p>","DOI":"10.31083\/j.rcm2504119","type":"journal-article","created":{"date-parts":[[2024,4,3]],"date-time":"2024-04-03T09:03:37Z","timestamp":1712135017000},"source":"Crossref","is-referenced-by-count":4,"title":["Longitudinal Stent Deformation at the Proximal Segment of the Left Main Coronary Artery Caused by a Stuck OCT Catheter: Case Report and Review of Literature"],"prefix":"10.31083","volume":"25","author":[{"given":"Ming","family":"Zhang","sequence":"first","affiliation":[{"name":"Senior Department of Cardiology, the First Medical Center of PLA General Hospital, 100853 Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xietian","family":"Pan","sequence":"first","affiliation":[{"name":"Senior Department of Cardiology, the Sixth Medical Center of PLA General Hospital, 100853 Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yabin","family":"Wang","sequence":"first","affiliation":[{"name":"Senior Department of Cardiology, the Second Medical Center of PLA General Hospital, 100853 Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuo","family":"Yin","sequence":"first","affiliation":[{"name":"Department of Cardiology, Gu'an County Hospital of Traditional Chinese Medicine, 065500 Langfang, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Bai","sequence":"first","affiliation":[{"name":"Senior Department of Cardiology, Yulin First Hospital, 719000 Yulin, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Gao","sequence":"first","affiliation":[{"name":"Senior Department of Cardiology, the Sixth Medical Center of PLA General Hospital, 100853 Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"16242","published-online":{"date-parts":[[2024,3,28]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","unstructured":"Williams PD, Mamas MA, Morgan KP, El-Omar M, Clarke B, Bainbridge A, et al. Longitudinal stent deformation: a retrospective analysis of frequency and mechanisms. EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2012; 8: 267\u2013274.","DOI":"10.4244\/EIJV8I2A41"},{"key":"ref2","doi-asserted-by":"crossref","unstructured":"Leibundgut G, Gick M, Toma A, Valina C, L\u00f6ffelhardt N, B\u00fcttner HJ, et al. Longitudinal compression of the platinum-chromium everolimus-eluting stent during coronary implantation: predisposing mechanical properties, incidence, and predictors in a large patient cohort. Catheterization and Cardiovascular Interventions: Official Journal of the Society for Cardiac Angiography & Interventions. 2013; 81: E206\u2013E214.","DOI":"10.1002\/ccd.24472"},{"key":"ref3","doi-asserted-by":"crossref","unstructured":"Arnous S, Shakhshir N, Wiper A, Ordoubadi FF, Williams P, Clarke B, et al. Incidence and mechanisms of longitudinal stent deformation associated with Biomatrix, Resolute, Element, and Xience stents: Angiographic and case-by-case review of 1,800 PCIs. Catheterization and Cardiovascular Interventions: Official Journal of the Society for Cardiac Angiography & Interventions. 2015; 86: 1002\u20131011.","DOI":"10.1002\/ccd.25790"},{"key":"ref4","doi-asserted-by":"crossref","unstructured":"Rhee TM, Park KW, Lee JM, Lee MS, Jeon KH, Kang HJ, et al. Predictors and Long-Term Clinical Outcome of Longitudinal Stent Deformation: Insights From Pooled Analysis of Korean Multicenter Drug-Eluting Stent Cohort. Circulation. Cardiovascular Interventions. 2017; 10: e005518.","DOI":"10.1161\/CIRCINTERVENTIONS.117.005518"},{"key":"ref5","doi-asserted-by":"crossref","unstructured":"Mamas MA, Williams PD. Longitudinal stent deformation: insights on mechanisms, treatments and outcomes from the Food and Drug Administration Manufacturer and User Facility Device Experience database. EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2012; 8: 196\u2013204.","DOI":"10.4244\/EIJV8I2A33"},{"key":"ref6","doi-asserted-by":"crossref","unstructured":"Si D, Yang H, Liu G, Tong Y, He Y. Treatment of longitudinal stent compression under intravenous ultrasound guidance: A case report. Medicine. 2017; 96: e9405.","DOI":"10.1097\/MD.0000000000009405"},{"key":"ref7","doi-asserted-by":"crossref","unstructured":"Cuenza LR, Yeo KK. Stent accordion phenomenon visualized with optical coherence tomography. Cardiovascular Diagnosis and Therapy. 2017; 7: 640\u2013642.","DOI":"10.21037\/cdt.2017.09.04"},{"key":"ref8","doi-asserted-by":"crossref","unstructured":"Y\u0131ld\u0131r\u0131m O, Gul M, Inci S, Akta\u015f H, Dogan P, Bozk\u0131r A, et al. A catastrophic nightmare of the interventional cardiologist: Iatrogenic left main artery dissection and longitudinal stent deformation. Intractable & Rare Diseases Research. 2018; 7: 209\u2013212.","DOI":"10.5582\/irdr.2018.01081"},{"key":"ref9","doi-asserted-by":"crossref","unstructured":"Kobayashi N, Hata N, Okazaki H, Shimizu W. Longitudinal stent deformation as a cause of very late stent thrombosis: Optical coherence tomography images. International Journal of Cardiology. 2016; 202: 601\u2013603.","DOI":"10.1016\/j.ijcard.2015.08.126"},{"key":"ref10","doi-asserted-by":"crossref","unstructured":"Panoulas VF, Demir OM, Ruparelia N, Malik I. Longitudinal deformation of a third generation zotarolimus eluting stent: \u201cThe concertina returns!\u201d. World Journal of Cardiology. 2017; 9: 60\u201364.","DOI":"10.4330\/wjc.v9.i1.60"},{"key":"ref11","doi-asserted-by":"crossref","unstructured":"Leong AM, Ong PJL, Ho HH, Watson T. Distal longitudinal deformation of a Synergy stent by jailed Rotawire guidewire. Herz. 2017; 42: 209\u2013210.","DOI":"10.1007\/s00059-016-4455-z"},{"key":"ref12","unstructured":"Yew KL, Cham YL. Longitudinal stent compression: a not so new percutaneous coronary angioplasty (PCI) complication. The Medical Journal of Malaysia. 2012; 67: 123\u2013124."},{"key":"ref13","doi-asserted-by":"crossref","unstructured":"Foerst J, Foin N, Hettleman B. Longitudinal stent compression demonstrated by angiographic \u201cwedding band\u201d and 3-dimensional optical coherence tomography. JACC. Cardiovascular Interventions. 2012; 5: e39\u2013e40.","DOI":"10.1016\/j.jcin.2012.08.015"},{"key":"ref14","doi-asserted-by":"crossref","unstructured":"Aung SM, Demir AS, Boztosun B. Accordion effect in a thin-strut coronary stent. Perfusion. 2012; 27: 435\u2013437.","DOI":"10.1177\/0267659112448110"},{"key":"ref15","doi-asserted-by":"crossref","unstructured":"Buysschaert I, Ughi GJ, Adriaenssens T, Vermeersch P. Very late stent thrombosis and longitudinal stent deformation. Acta Cardiologica. 2017; 72: 216\u2013217.","DOI":"10.1080\/00015385.2017.1291203"},{"key":"ref16","unstructured":"Hern\u00e1ndez-Matamoros H, Gonz\u00e1lvez-Garcia A, Moreno-G\u00f3mez R, Jim\u00e9nez-Valero S. Longitudinal Stent Deformation: Precise Diagnosis With Optical Coherence Tomography. The Journal of Invasive Cardiology. 2019; 31: E395."},{"key":"ref17","doi-asserted-by":"crossref","unstructured":"Vijayvergiya R, Sharma P, Gupta A, Goyal P, Panda P. Longitudinal stent deformation during coronary bifurcation stenting. Cardiovascular Revascularization Medicine: Including Molecular Interventions. 2016; 17: 143\u2013145.","DOI":"10.1016\/j.carrev.2015.12.004"},{"key":"ref18","unstructured":"Demir OM, Ruparelia N, Khan M, Baker C. Coronary Intervention Complicated by Pressure Wires Caught Within Stent Struts. The Journal of Invasive Cardiology. 2017; 29: E102\u2013E103."},{"key":"ref19","doi-asserted-by":"crossref","unstructured":"Hanratty CG, Walsh SJ. Longitudinal compression: a \u201cnew\u201d complication with modern coronary stent platforms\u2013time to think beyond deliverability? EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2011; 7: 872\u2013877.","DOI":"10.4244\/EIJV7I7A135"},{"key":"ref20","doi-asserted-by":"crossref","unstructured":"Shannon J, Latib A, Takagi K, Chieffo A, Figini F, Sacco F, et al. \u201cProcedural trauma risks longitudinal shortening of the Promus Element\u2122 stent platform\u201d. Catheterization and Cardiovascular Interventions: Official Journal of the Society for Cardiac Angiography & Interventions. 2013; 81: 810\u2013817.","DOI":"10.1002\/ccd.24600"},{"key":"ref21","doi-asserted-by":"crossref","unstructured":"Cosgrove C, Marciniak M, Spratt JC. Reverse longitudinal stent deformation during percutaneous intervention via the retrograde approach to a chronic total occlusion of the right coronary artery: a case report. European Heart Journal. Case Reports. 2021; 5: ytaa571.","DOI":"10.1093\/ehjcr\/ytaa571"},{"key":"ref22","doi-asserted-by":"crossref","unstructured":"Chung MS, Yang DH, Kim YH, Roh JH, Song J, Kang JW, et al. Stent fracture and longitudinal compression detected on coronary CT angiography in the first- and new-generation drug-eluting stents. The International Journal of Cardiovascular Imaging. 2016; 32: 637\u2013646.","DOI":"10.1007\/s10554-015-0798-4"},{"key":"ref23","doi-asserted-by":"crossref","unstructured":"Prabhu S, Schikorr T, Mahmoud T, Jacobs J, Potgieter A, Simonton C. Engineering assessment of the longitudinal compression behaviour of contemporary coronary stents. EuroIntervention: Journal of EuroPCR in Collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2012; 8: 275\u2013281.","DOI":"10.4244\/EIJV8I2A42"},{"key":"ref24","doi-asserted-by":"crossref","unstructured":"Ormiston JA, Webber B, Webster MWI. Stent longitudinal integrity bench insights into a clinical problem. JACC. Cardiovascular Interventions. 2011; 4: 1310\u20131317.","DOI":"10.1016\/j.jcin.2011.11.002"},{"key":"ref25","doi-asserted-by":"crossref","unstructured":"Shibutani H, Akita Y, Oishi Y, Sueyoshi H, Mukai Y, Yutaka K, et al. The potential hazard of a non-slip element balloon causing distal longitudinal stent deformation: the first clinical experience and in vitro assessment. Cardiology Journal. 2019; 26: 645\u2013652.","DOI":"10.5603\/CJ.a2018.0065"}],"container-title":["Reviews in Cardiovascular Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.imrpress.com\/journal\/RCM\/25\/4\/10.31083\/j.rcm2504119","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T19:14:06Z","timestamp":1732734846000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.imrpress.com\/journal\/RCM\/25\/4\/10.31083\/j.rcm2504119"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,28]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"alternative-id":["S1530-6550(23)01230-9"],"URL":"https:\/\/doi.org\/10.31083\/j.rcm2504119","relation":{},"ISSN":["1530-6550","2153-8174"],"issn-type":[{"value":"1530-6550","type":"print"},{"value":"2153-8174","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,28]]},"article-number":"119"}}