{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T04:57:36Z","timestamp":1768280256718,"version":"3.49.0"},"reference-count":33,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["PED"],"published-print":{"date-parts":[[2009,6]]},"abstract":"<jats:sec>\n<jats:title>Object<\/jats:title>\n<jats:p>Rigid fixation of the upper cervical spine has become an established method of durable stabilization for a variety of craniocervical pathological entities in children. In children, specifically, the use of C1\u20132 transarticular screws has been proposed in recent literature to be the gold standard configuration for pathology involving these levels. The authors reviewed the use of rigid fixation techniques alternative to C1\u20132 transarticular screws in children. Factors evaluated included ease of placement, complications, and postoperative stability.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Seventeen patients, ranging in age from 3 to 17 years (mean 9.6 years), underwent screw fixation involving the atlas or axis for a multitude of pathologies, including os odontoideum, Down syndrome, congenital instability, iatrogenic instability, or posttraumatic instability. All patients had preoperative instability of the occipitocervical or atlantoaxial spine demonstrated on dynamic lateral cervical spine radiographs. All patients also underwent preoperative CT scanning and MR imaging to evaluate the anatomical feasibility of the selected hardware placement. Thirteen patients underwent C1\u20132 fusion, and 4 underwent occipitocervical fusion, all incorporating C-1 lateral mass screws, C-2 pars screws, and\/or C-2 laminar screws within their constructs. Patients who underwent occipitocervical fusion had no instrumentation placed at C-1. One patient's construct included sublaminar wiring at C-2. All patients received autograft onlay either from from rib (in 15 patients), split-thickness skull (1 patient), or local bone harvested within the operative field (1 patient). Nine patients' constructs were supplemented with recombinant human bone morphogenetic protein at the discretion of the attending physician. Eight patients had surgical sacrifice of 1 or both C-2 nerve roots to better facilitate visualization of the C-1 lateral mass. One patient was placed in halo-vest orthosis postoperatively, while the rest were maintained in rigid collars.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>All 17 patients underwent immediate postoperative CT scanning to evaluate hardware placement. Follow-up was achieved in 16 cases, ranging from 2 to 39 months (mean 14 months), and repeated dynamic lateral cervical spine radiography was performed in these patients at the end of their follow-up period. Some, but not all patients, also underwent delayed postoperative CT scans, which were done at the discretion of the treating attending physician. No neurovascular injuries were encountered, no hardware revisions were required, and no infections were seen. No postoperative pain was seen in patients who underwent C-2 nerve root sacrifice. Stability was achieved in all patients postoperatively. In all patients who underwent delayed postoperative CT scanning, the presence of bridging bone was shown spanning the fused levels.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Screw fixation of the atlas using lateral mass screws, in conjunction with C-2 root sacrifice in selected cases, and of the axis using pars or laminar screws is a safe method for achieving rigid fixation of the upper cervical spine in the pediatric population.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2009.2.peds08149","type":"journal-article","created":{"date-parts":[[2009,9,22]],"date-time":"2009-09-22T12:26:08Z","timestamp":1253622368000},"page":"529-533","source":"Crossref","is-referenced-by-count":65,"title":["Screw fixation of the upper cervical spine in the pediatric population"],"prefix":"10.3171","volume":"3","author":[{"given":"Atif","family":"Haque","sequence":"first","affiliation":[{"name":"Department of Neurological Surgery, University of Texas Southwestern Medical Center; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angela V.","family":"Price","sequence":"additional","affiliation":[{"name":"Neurosurgeons for Children, Dallas, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frederick H.","family":"Sklar","sequence":"additional","affiliation":[{"name":"Neurosurgeons for Children, Dallas, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dale M.","family":"Swift","sequence":"additional","affiliation":[{"name":"Neurosurgeons for Children, Dallas, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bradley E.","family":"Weprin","sequence":"additional","affiliation":[{"name":"Neurosurgeons for Children, Dallas, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David J.","family":"Sacco","sequence":"additional","affiliation":[{"name":"Neurosurgeons for Children, Dallas, Texas"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1754","reference":[{"issue":"1 Suppl","key":"b1-0030529","series-title":"J Neurosurg","first-page":"36","article-title":"Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients","volume":"107","author":"Anderson","year":"2007"},{"key":"b2-0030529","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"222","DOI":"10.3171\/SPI\/2008\/8\/3\/222","article-title":"Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques","volume":"8","author":"Aryan","year":"2008"},{"key":"b3-0030529","series-title":"Pediatr Neurosurg","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1159\/000094073","article-title":"Internal reduction established by occiput-C2 pedicle polyaxial screw stabilization in pediatric atlantoaxial rotatory fixation","volume":"42","author":"Belen","year":"2006"},{"issue":"5 Suppl 2","key":"b4-0030529","series-title":"Neurosurgery","first-page":"ONS423","article-title":"A comprehensive review of the safety profile of bone morphogenetic protein in spine surgery","volume":"62","author":"Benglis","year":"2008"},{"key":"b5-0030529","series-title":"Pediatr Neurosurg","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1159\/000120893","article-title":"Pediatric cervical spine instrumentation using screw fixation","volume":"22","author":"Brockmeyer","year":"1995"},{"issue":"2 Suppl","key":"b6-0030529","series-title":"J Neurosurg","first-page":"173","article-title":"Lateral mass screw fixation of C-1","volume":"107","author":"Brockmeyer","year":"2007"},{"issue":"1 Suppl","key":"b7-0030529","series-title":"J Neurosurg","first-page":"7","article-title":"Anatomical suitability of C1-2 transarticular screw placement in pediatric patients","volume":"92","author":"Brockmeyer","year":"2000"},{"key":"b8-0030529","series-title":"Spine","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1097\/BRS.0b013e318166e083","article-title":"Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra: implications for C1\u2013C2 transarticular and C1 lateral mass fixation","volume":"33","author":"Currier","year":"2008"},{"key":"b9-0030529","series-title":"Spine","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1097\/01.BRS.0000058724.95657.55","article-title":"Quantitative anatomy of the lateral mass of the atlas","volume":"28","author":"Dong","year":"2003"},{"key":"b10-0030529","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"164","DOI":"10.3171\/spi.2005.2.2.0164","article-title":"Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients","volume":"2","author":"Gluf","year":"2005"},{"key":"b11-0030529","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1513","DOI":"10.1097\/01.brs.0000167827.84020.49","article-title":"Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation","volume":"30","author":"Gorek","year":"2005"},{"key":"b12-0030529","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1\u2013C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms","year":"2001"},{"key":"b13-0030529","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"336","DOI":"10.3171\/spi.2006.5.4.336","article-title":"Biomechanical comparison of two new atlantoaxial fixation techniques with C1\u20132 transarticular screwgraft fixation","volume":"5","author":"H\u00e4rtl","year":"2006"},{"key":"b14-0030529","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3171\/spi.2005.2.2.0175","article-title":"Biomechanical comparison of C1\u20132 posterior fixation techniques","volume":"2","author":"Hott","year":"2005"},{"issue":"2 Suppl","key":"b15-0030529","series-title":"J Neurosurg","first-page":"178","article-title":"Incorporation of C-1 lateral mass screws in occipitocervical and atlantoaxial fusions for children 8 years of age or younger","volume":"107","author":"Jea","year":"2007"},{"issue":"1 Suppl","key":"b16-0030529","series-title":"Neurosurgery","first-page":"151","article-title":"Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation","volume":"56","author":"Kuroki","year":"2005"},{"issue":"1 Suppl","key":"b17-0030529","series-title":"J Neurosurg","first-page":"59","article-title":"Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. Technical note","volume":"104","author":"Leonard","year":"2006"},{"key":"b18-0030529","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"671","DOI":"10.3171\/jns.1997.87.5.0671","article-title":"Upper cervical spine fusion in the pediatric population","volume":"87","author":"Lowry","year":"1997"},{"key":"b19-0030529","series-title":"Cervical Spine","first-page":"322","article-title":"Stable posterior fusion of the atlas and axis by transarticular screw fixation","volume":"Vol 1","author":"Magerl","year":"1987"},{"key":"b20-0030529","series-title":"Pediatr Neurosurg","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1159\/000149907","article-title":"Use of recombinant human bone morphogenetic protein-2 to enhance posterior cervical spine fusion at 2 years of age: technical note","volume":"44","author":"Oluigbo","year":"2008"},{"key":"b21-0030529","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"221","DOI":"10.3171\/jns.1996.85.2.0221","article-title":"The anatomical suitability of the C1\u20132 complex for transarticular screw fixation","volume":"85","author":"Paramore","year":"1996"},{"issue":"6","key":"b22-0030529","series-title":"Neurosurg Focus","first-page":"ECP1","article-title":"Treatment of atlantoaxial instability in pediatric patients","volume":"15","author":"Rahimi","year":"2003"},{"key":"b23-0030529","series-title":"J Pediatr Orthop","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1097\/01.bpo.0000230337.26652.55","article-title":"Transarticular screws in the management of C1\u2013C2 instability in children","volume":"26","author":"Reilly","year":"2006"},{"key":"b24-0030529","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"327","DOI":"10.3171\/SPI\/2008\/8\/4\/327","article-title":"Laminar screw fixation of the axis","volume":"8","author":"Sciubba","year":"2008"},{"issue":"1","key":"b25-0030529","series-title":"Neurosurg Focus","first-page":"E6","article-title":"Posterior atlantoaxial stabilization: new alternative to C1\u20132 transarticular screws","volume":"12","author":"Stokes","year":"2002"},{"key":"b26-0030529","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1007\/s00586-006-0241-6","article-title":"Atlantoaxial fixation using the polyaxial screw-rod system","volume":"16","author":"Stulik","year":"2007"},{"key":"b27-0030529","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1097\/00024720-200406000-00005","article-title":"Case-control study comparing the efficacy of surgical techniques for C1\u2013C2 arthrodesis","volume":"17","author":"Taggard","year":"2004"},{"issue":"2 Suppl","key":"b28-0030529","series-title":"J Neurosurg","first-page":"205","article-title":"Treatment of Down syndrome-associated craniovertebral junction abnormalities","volume":"93","author":"Taggard","year":"2000"},{"key":"b29-0030529","series-title":"Spine","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1097\/01.BRS.0000058719.48596.CC","article-title":"Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass","volume":"28","author":"Tan","year":"2003"},{"key":"b30-0030529","series-title":"Pediatr Neurosurg","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1159\/000028766","article-title":"Pediatric atlantoaxial instability: management with screw fixation","volume":"30","author":"Wang","year":"1999"},{"key":"b31-0030529","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1097\/00024720-200404000-00014","article-title":"Posterior C2 fixation using bilateral, crossing C2 laminar screws","volume":"17","author":"Wright","year":"2004"},{"key":"b32-0030529","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"634","DOI":"10.3171\/jns.1998.88.4.0634","article-title":"Vertebral artery injury in C1\u20132 transarticular screw fixation: results of a survey of the AANS\/CNS Section on Disorders of the Spine and Peripheral Nerves","volume":"88","author":"Wright","year":"1998"},{"key":"b33-0030529","series-title":"Spine","doi-asserted-by":"publisher","first-page":"E513","DOI":"10.1097\/01.brs.0000224516.29747.52","article-title":"Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw","volume":"31","author":"Yoshida","year":"2006"}],"container-title":["Journal of Neurosurgery: Pediatrics"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/3\/6\/article-p529.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/3\/6\/article-p529.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-pediatr\/3\/6\/article-p529.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T11:49:02Z","timestamp":1681559342000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-pediatr\/3\/6\/article-p529.xml"}},"subtitle":["Clinical article"],"short-title":[],"issued":{"date-parts":[[2009,6]]},"references-count":33,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3171\/2009.2.peds08149","relation":{},"ISSN":["1933-0707","1933-0715"],"issn-type":[{"value":"1933-0707","type":"print"},{"value":"1933-0715","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,6]]}}}