{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T08:58:31Z","timestamp":1781427511030,"version":"3.54.1"},"reference-count":25,"publisher":"Journal of Neurosurgery Publishing Group (JNSPG)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SPI"],"published-print":{"date-parts":[[2009,7]]},"abstract":"<jats:sec>\n<jats:title>Object<\/jats:title>\n<jats:p>Stabilization of the cervical spine can be challenging when instrumentation involves the axis. Fixation with C1\u20132 transarticular screws combined with posterior wiring and bone graft placement has yielded excellent fusion rates, but the technique is technically demanding and places the vertebral arteries (VAs) at risk. Placement of screws in the pars interarticularis of C-2 as described by Harms and Melcher has allowed rigid fixation with greater ease and theoretically decreases the risk to the VA. However, fluoroscopy is suggested to avoid penetration laterally, medially, and superiorly to avoid damage to the VA, spinal cord, and C1\u20132 joint, respectively. The authors describe how, after meticulous dissection of the C-2 pars interarticularis, such screws can be placed accurately and safely without the use of fluoroscopy.<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Prospective follow-up was performed in 55 consecutive patients who underwent instrumented fusion of C-2 by a single surgeon. The causes of spinal instability and type and extent of instrumentation were documented. All patients underwent preoperative CT or MR imaging scans to determine the suitability of C-2 screw placement. Intraoperatively, screws were placed following dissection of the posterior pars interarticularis. Postoperative CT scans were performed to determine the extent of cortical breach. Patients underwent clinical follow-up, and complications were recorded as vascular or neurological. A CT-based grading system was created to characterize such breaches objectively by location and magnitude via percentage of screw diameter beyond the cortical edge (0 = none; I = &lt; 25% of screw diameter; II = 26\u201350%; III = 51\u201375%; IV = 76\u2013100%).<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>One-hundred consecutive screws were placed in the pedicle of the axis by a single surgeon using external landmarks only. In 10 cases, only 1 screw was placed because of a preexisting VA anatomy or bone abnormality noted preoperatively. In no case was screw placement aborted because of complications noted during drilling. Early complications occurred in 2 patients and were limited to 1 wound infection and 1 transient C-2 radiculopathy. There were 15 total breaches (15%), 2 of which occurred in the same patient. Twelve breaches were lateral (80%), and 3 were superior (20%). There were no medial breaches. The magnitude of the breach was classified as I in 10 cases (66.7% of breaches), II in 3 cases (20% of breaches), III in 1 case (6.7%), and IV in 1 case (6.7%).<\/jats:p><\/jats:sec>\n<jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Free-hand placement of screws in the C-2 pedicle can be done safely and effectively without the use of intraoperative fluoroscopy or navigation when the pars interarticularis\/pedicle is assessed preoperatively with CT or MR imaging and found to be suitable for screw placement. When breaches do occur, they are overwhelmingly lateral in location, breach &lt; 50% of the screw diameter, and in the authors' experience, are not clinically significant.<\/jats:p><\/jats:sec>","DOI":"10.3171\/2009.3.spine08166","type":"journal-article","created":{"date-parts":[[2009,7,1]],"date-time":"2009-07-01T17:28:30Z","timestamp":1246469310000},"page":"15-22","source":"Crossref","is-referenced-by-count":50,"title":["Radiographic and clinical evaluation of free-hand placement of C-2 pedicle screws"],"prefix":"10.3171","volume":"11","author":[{"given":"Daniel M.","family":"Sciubba","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph C.","family":"Noggle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ananth K.","family":"Vellimana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan","family":"Alosh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew J.","family":"McGirt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziya L.","family":"Gokaslan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Paul","family":"Wolinsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1754","reference":[{"key":"b1-0110015","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1227\/00006123-199510000-00012","article-title":"C1-C2 posterior cervical fusion: long-term evaluation of results and efficacy","volume":"37","author":"Coyne","year":"1995"},{"key":"b2-0110015","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"316","DOI":"10.3171\/jns.1996.85.2.0316","article-title":"Biomechanical characteristics of C1-2 cable fixations","volume":"85","author":"Dickman","year":"1996"},{"key":"b3-0110015","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1097\/00006123-199808000-00056","article-title":"Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis","volume":"43","author":"Dickman","year":"1998"},{"key":"b4-0110015","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"8","DOI":"10.3171\/jns.1998.89.1.0008","article-title":"Posterior atlantoaxial facet screw fixation in rheumatoid arthritis","volume":"89","author":"Eleraky","year":"1998"},{"key":"b5-0110015","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"164","DOI":"10.3171\/spi.2005.2.2.0164","article-title":"Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients","volume":"2","author":"Gluf","year":"2005"},{"key":"b6-0110015","series-title":"J Neurosurg Spine","doi-asserted-by":"publisher","first-page":"155","DOI":"10.3171\/spi.2005.2.2.0155","article-title":"Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients","volume":"2","author":"Gluf","year":"2005"},{"key":"b7-0110015","series-title":"Eur Spine J","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1007\/s00586-005-0963-x","article-title":"Transarticular screw fixation for osteoarthritis of the atlanto axial segment","volume":"15","author":"Grob","year":"2006"},{"key":"b8-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1097\/00007632-199205000-00003","article-title":"Biomechanical evaluation of four different posterior atlantoaxial fixation techniques","volume":"17","author":"Grob","year":"1992"},{"key":"b9-0110015","series-title":"J Spinal Disord Tech","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1097\/01.bsd.0000211291.21766.4d","article-title":"The use of C1 lateral mass screws in complex cervical spine surgery: indications, techniques, and outcome in a prospective consecutive series of 25 cases","volume":"20","author":"Gunnarsson","year":"2007"},{"key":"b10-0110015","series-title":"Neurosurgery","first-page":"65","article-title":"C1-C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience","volume":"49","author":"Haid","year":"2001"},{"key":"b11-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1097\/00007632-199110000-00002","article-title":"Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability","volume":"16","author":"Hanson","year":"1991"},{"key":"b12-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1-C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms","year":"2001"},{"key":"b13-0110015","series-title":"J Spinal Disord","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1097\/00002517-199212000-00012","article-title":"Primary posterior fusion C1\/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation","volume":"5","author":"Jeanneret","year":"1992"},{"key":"b14-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1703","DOI":"10.1097\/00007632-199808010-00018","article-title":"Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation","volume":"23","author":"Jun","year":"1998"},{"key":"b15-0110015","series-title":"J Neurosurg","doi-asserted-by":"publisher","first-page":"961","DOI":"10.3171\/jns.1997.86.6.0961","article-title":"Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique","volume":"86","author":"Madawi","year":"1997"},{"key":"b16-0110015","series-title":"J Orthop Trauma","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1097\/00005131-199909000-00004","article-title":"Biomechanical study of atlantoaxial arthrodesis: transarticular screw fixation versus modified Brooks posterior wiring","volume":"13","author":"Mitchell","year":"1999"},{"key":"b17-0110015","series-title":"Spine","first-page":"2800","article-title":"The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae","volume":"15","author":"Neo","year":"2005"},{"key":"b18-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"2449","DOI":"10.1097\/00007632-200111150-00011","article-title":"A finite element investigation of upper cervical instrumentation","volume":"26","author":"Puttlitz","year":"2001"},{"key":"b19-0110015","series-title":"Chin J Traumatol","first-page":"89","article-title":"Biomechanical evaluation of atlantoaxial transarticular screw fixation technique","volume":"3","author":"Qu","year":"2000"},{"key":"b20-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1097\/00007632-200207150-00003","article-title":"Anatomic suitability of the C1-C2 complex for pedicle screw fixation","volume":"27","author":"Resnick","year":"2002"},{"key":"b21-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1724","DOI":"10.1097\/00007632-200208150-00008","article-title":"Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques","volume":"27","author":"Richter","year":"2002"},{"key":"b22-0110015","series-title":"Spine","doi-asserted-by":"publisher","first-page":"1477","DOI":"10.1097\/00007632-199907150-00014","article-title":"Peroperative determination of safe superior transarticular screw trajectory through the lateral mass","volume":"24","author":"Solanki","year":"1999"},{"key":"b23-0110015","series-title":"Neurosurg Rev","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1007\/s10143-005-0003-7","article-title":"Virtual placement of posterior C1-C2 transarticular screw fixation","volume":"29","author":"Spangenberg","year":"2006"},{"key":"b24-0110015","series-title":"Neurosurgery","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1227\/00006123-199306000-00011","article-title":"Atlanto-axial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases","volume":"32","author":"Stillerman","year":"1993"},{"key":"b25-0110015","series-title":"Pediatr Neurosurg","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1159\/000028766","article-title":"Pediatric atlantoaxial instability: management with screw fixation","volume":"30","author":"Wang","year":"1999"}],"container-title":["Journal of Neurosurgery: Spine"],"original-title":[],"link":[{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/11\/1\/article-p15.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/11\/1\/article-p15.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/thejns.org\/downloadpdf\/journals\/j-neurosurg-spine\/11\/1\/article-p15.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T21:29:36Z","timestamp":1681594176000},"score":1,"resource":{"primary":{"URL":"https:\/\/thejns.org\/view\/journals\/j-neurosurg-spine\/11\/1\/article-p15.xml"}},"subtitle":["Clinical article"],"short-title":[],"issued":{"date-parts":[[2009,7]]},"references-count":25,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3171\/2009.3.spine08166","relation":{},"ISSN":["1547-5654"],"issn-type":[{"value":"1547-5654","type":"print"}],"subject":[],"published":{"date-parts":[[2009,7]]}}}